HomeMy WebLinkAboutEngineer PlanT.O.F. EL.= 23.1 't
FINISH GRADE
@ FND. EL.= 21.5't
J�--EXISTING r
SEWER PIPE
6" 311
NTRACTOR TO PROVIDE I
FCIFIED DROP BETWEEN
ET AND OUTLET
xc:isi»i i°iA ; i OR TO Vi:KiFY EXISTIII
ELEVATION PRIOR TO ANY WORK &
NOTIFY ENGINEER IF DIFFERENT.
PROPOSED EXTENSION RISER
WITH COVER OVER INLET &
OUTLET TO WITHIN 6" OF F.G.
3" DROP MAX '
2" DROP MIN 3„ 9„
F.G. OVER TANK EL. = 195 - 21 .0'
PROPOSED 4"
SCH. 40 PVC
SEWER PIPE
- *18.4t
CONTRACTOR UUN I KAU I UK ZINALL
SHALL VERIFY SIZE 48" VERIFY CONDITION OF \ OUTLET TEE
AND CONDITION OF EXISTING TEES GAS BAFFLE
EXISTING SEPTIC AND REPLACE AS
TANK NECESSARY
EXISTING 1,000 GALLON CONCRETE SEPTIC TANK
PROPOSED TWO (2)
500-GALLON H-20 LEACHING
CHAMBERS w/ STONE
PROPOSED H-20
DISTRIBUTION BOX
PROPOSED PVC VENT.
N
OA'
BUSH
� \ (TYP) ,
ti
NOT TO SCALE
EXISTING 1,000 GALLON
TANK TO BE UTILIZED IN
THIS DESIGN
MAP 58
PARCEL 271
G
O� O ` l�117 , O ♦ \ d
.� '� ♦ 0
`y
G� 7 ♦� \�16 �3
NOTES:
1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF
EACH SEPTIC SYSTEM COMPONENT.
2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE
PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT
DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF
HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA.
3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II.
,�,niki ^Ki Tuio ni AKi ADC oonvinCn nw v AQ A r'.nl IRTFSY
FINISH GRADE OVER D-BOX = 22.1 'f
REMOVABLE WATER -TIGHT COVER OVER
1 F
RISER TO WITHIN 6" OF FINISHED GRADE 4" SCHEDULE 40 PVC
r5" DIA. OUTLET(S) MIN SLOPE 1%
1 I
3.6' MAX.
SEE NOTE 22 17.20' SEE NOTE 22
T I
L=82 t PROVIDE WATERTIGHT
0 0
FINISH GRADE OVER CHAMBERS = 21.9' - 22.2'
SLOPE @ 2% MIN. OVER SYSTEM
TOP OF SAS = 18.20'
BREAKOUT EL = 17.70' --,,
4" PVC IN FROM JOINTS (TYP.)
o�
SEPTIC TANK 4" PVC OUT TO = = = O
LEACHING FACILITY oo 0 0 0
00 0 0
17.50' MIN. 6"17.33' 2'__// I
6" CRUSHED STONE 0 0
OVER MECHANICALLY o0
COMPACTED BASE 4 0,
8. 5' (TYP)
5
OUTLET DISTRIBUTION BOX
TO BE INSTALLED ON A LEVEL STABLE
BASE. FIRST TWO FEET OF OUTLET 15.20'
PIPES TO BE LAID LEVEL.
q( i C�RiOS jS.�SECTI�O�N VI(� `E�W +
NOT TO SCALE
EXISTING LEACHING PIT TO BE
PUMPED AND FILLED WITH CLEAN,
COARSE SAND AND ABANDONED - ..
EXISTING DISTRIBUTION
BOX TO BE ABANDONED -
0
SWING -TIES
25.0
GROUND WATER ELEV.=
PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE GENERAL NOTES
3/4" TO 1-1/2" DOUBLE WASHED
STONE TO CROWN OF PIPE 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION
2" OF 1/8" TO 1/2" DOUBLE WASHED METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL
STONE OR GEOTEXTILE FILTER FABRIC CODE AND ANY APPLICABLE LOCAL RULES.
2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
PLACE H-20 RISER ON
ALL CHAMBERS wl 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL
PIPED INLETS TO SYSTEM UNLESS OTHERWISE NOTED.
WITHIN 6" OF F.G.-�
4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN
ELEVATION = 17.70' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A
40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF
O
THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION.
0
5. SLOPE ALL SOLID PIPE AT 1.0%MINIMUM.
6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.
CDC)0
o00
7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK
000
o
0o
o
FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS
NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH
AND DESIGN ENGINEER.
4.0'
4 83'
4.0
8. ELEVATIONS BASED ON N.A.V.D. 88 DATUM. SEE BENCHMARK LOCATION AND ELEVATION
(TYP.)
SHOWN ON PLAN.
12 83'
9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION
THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT
2 - 500 GALLON H-20 CHAMBERS \-5' MIN. CHAMBEf-, END VIEW 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES
TYPICAL CHAMBER PROFILE H-20 CHMARER DETAILS
NOT TO SCALE
a
DESCRIPTION
HC-1
HC-2
CORNER OF STONE (1)
18.4'
27.6'
CORNER OF STONE (2)
29.9'
36.0'
CORNER OF STONE (3)
31.6'
55.7'
CORNER OF STONE (4)
21.0'
50.6'
MAP 58
PARCEL 273
A
LOCUS PLAN
SCALE: 1" = 1000'
DESIGN DATA
NUMBER OF BEDROOMS (EXISTING) 2
NUMBER OF BEDROOMS (DESIGN) 3 (MIN. PER TITLE 5)
DESIGN FLOW 110 GAL/DAY/BEDROOM
TOTAL DESIGN FLOW 330 GAUDAY
DESIGN FLOW x 200 % = 660 GAL/DAY
USE EXISTING 1,000 GALLON SEPTIC TANK
TO THE DESIGN ENGINEER.
10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT.
- -
11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING
TEST PIT DATA
REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM
N/A
APPROPRIATE AUTHORITY.
PERC NO.
12, ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED
INSPECTOR: Phil Reneaud (BOH)
UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR
EVALUATOR: Michael Pimentel, EIT, CSE
TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING.
r,
C.S.E. APPROVAL DATE: Oct. 27, 1999
13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES.
DATE: April 6, 2023
14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE
TEST PIT #: 1
MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY.
ELEV TOP = 22.00'
REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY,
FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3).
•
ELEV WATER = < 10.00'
15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN
PERC RATE _ < 2 min./inch
SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK.
DEPTH OF PERC - 30" - 48"
16. PROPOSED PROJECT IS LOCATED WITHIN:
ASSESSOR'S MAP 58 LOT 272
TEXTURAL CLASS: I
OWNER OF RECORD: MARY E. MCLAUGHLIN
R SS 88 CLEAR BROOK ROAD
INSTALL 2 - 500 GAL. H-20 CHAMBERS w/ STONE
SIDEWALL CAPACITY
(LENGTH + WIDTH) (2 SIDES) (Z HIGH) (0.74 GPD/S.F.) = GAUDAY
(25.0' + 12.83') ( 2 ) (7) (0.74 GPD/ S.F.) =112.0 GAUDAY
BOTTOM CAPACITY
(LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY
(25.0' x 12.83') (0.74 GPD/S.F.) = 237.4 GAUDAY
TOTALS:
TOTAL NUMBER OF CHAMBERS 2
TOTAL LEACHING AREA 472.2 SQ.FT.
TOTAL LEACHING CAPACITY 349.4 GAL./DAY
RESERVED FOR BOARD OF HEALTH USE
6"
B
30"
Perc
48"
C
Loamy Sand
10Yr 3/1
Loamy Sand
10Y r 5/8
Very Fine Sand
2.5Y 6/6
22.00
ADD E
WEST YARMOUTH MA
21.50'
FEMA FLOOD ZONE X
COMMUNITY PANEL # 25001CO587J
19.50' 17.
DEED REFERENCE: BOOK 12716, PAGE 222
18.
PLAN REFERENCE: PLAN BOOK 279, PAGES 85-86
19.
ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
20.
PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY
FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY
FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE.
21.
OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL
REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT.
22,
IN ACCORDANCE WITH 310 CMR 16.401-15.405, THE FOLLOWING LOCAL UPGRADE
APPROVALS ARE REQUESTED FROM 310 CMR 15.211 & 15.221(7):
(1.) A 5.0' WAIVER (20.0' - 15.0') FOR THE SETBACK FROM THE SAS TO HOUSE FOUNDATION.
(2.) A 5.0' WAIVER (10.0' - 5.0') FOR THE SETBACK FROM THE SAS TO FRONT PROPERTY LINE.
(3.) A 0.6' WAIVER (3.0' - 3.6') FOR THE MAXIMUM COVER OVER THE H-20 D-BOX.
144" l ' 10.00, (4.) A 1.0' WAIVER (3.0' - 4.0') FOR THE MAXIMUM COVER OVER THE H-20 SAS.
No Mottling, Standing or Weeping Observed
Permit valid for REPAIR OF sEP"I'IC SYSTEM
OXO'
O',I.V, due to StIte and local septic variances.
li,,;,rd of Health review and approval is required for
50 - ----
anv future addiiions/renovations/alterations to
sewage facilities and/or structures/dwelling.
50
Yarmouth Health Department
APPROVED
50
me Date
13
EXISTING SPOT GRADE RECEIVE
EXISTING CONTOUR
PROPOSED CONTOUR MAY 12 2023
PROPOSED SPOT GRADE HEALTH DEPT
EXISTING GAS LINE
EXISTING OVERHEAD UTILITIES
EXISTING WATER LINE
EXISTING LANDSCAPED AREA
TEST PIT LOCATION
EXISTING 1,000 GALLON SEPTIC TANK
PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE
PROPOSED H-20 DISTRIBUTION BOX
PROPOSED 500 GALLON H-20 LEACHING CHAMBER
REV. DATE BY APP'D. DESCRIPTION
PROPOSED SEPTIC SYSTEM UPGRADE
OF MASS PREPARED FOR
J"
ROBERT B. OUR CO., INC.
o CHI ILL JR.
U IVIL y
N 48066
LOCATED AT
�2tsT
88 CLEAR BROOK ROAD
WEST YARMOUTH, MA
SCALE: 1 INCH = 10 FT. DATE: MAY 8, 2023
0 5 10 20 40 FEET
p�ZN <1F MASSycmwmmmmwmoi
JOHN L. y°.r PREPARED BY
o CHUR' JC ENGINEERING, INC.
N G
2854 CRANBERRY HIGHWAY
j rS� EAST WAREHAM, MA 02538