Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YAR1 IOUTH SEWAGE/ PLAN REVIEW CHECKLIST/ Location: A.M. /OD Lot y� Zone of Contribution: In Out t /s Acreage , 7 Commercial: Street: A) rf l n ;A � -- Residential: Village: ` Floor Plan: # Bedrooms: 2 Owner: Installer: C L p-e- ac13 L Address: Phone: Phone: Builder: Engineer: C ,u3 r to,Q P_1L c.�d r/c� Address: Phone: /` Phone: 1. Required#of copies received N/A YES I NO ✓ 2. Date of soils exam and percolation test not older than 2 years -- 3. 4-5 ft of naturally occurring pervious material, above water table A.._ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ----- 5. Water line 10 ft from septic components Var.: I - 6. Benchmark indicated and shown-NGVD if near wetlands i v 7. Septic tank minimum 10 ft from foundation, deck Var.: I I a/ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I l/9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: I /7 11. Tank/leaching minimum 10 ft from property line Var.: !� 12. System meets all other setback requirements Var.: \` I 13. Uses adjustment for maximum high groundwater Var.: i/ 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal I C� 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred _1_8. System meets breakout requirements PVC liner: Wall: / 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel / 21. No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox I 24. Manhole covers within 6"of grade, pump chamber cover to grade / 25. Inspection port on plastic chambers/leach field r 26. Electrical permit for pump chamber/Separate meter for duplexes 27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size V. 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber l/ 31. Engineer to inspect and certify soils: wall: commercial: I r J 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater "a." 34.Title V Application and permit fee, installer signature c/ 35. Foundation footing min. 2 feet above adjusted ground water for new house ✓ 36.Deed Restriction required max. #bedrooms: max. flow: gpd I 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by. r co;o, v1;3