HomeMy WebLinkAboutAdmin Review 6.1.23LEGEND - - LAIJIINL, UUNIUUK X 99. 1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR [98.41 PROPOSED SPOT EL. TH1 TEST HOLE 27. SLOPE OF GROUND I-Q) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE DCE # > 8-087 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 9 BEDROOMS @ 110 GPD = 990 GPD USE A 990 GPD DESIGN FLOW SEPTIC TANK: 990 GPD (2) = 1980 **USE EXISTING 1000 GAL SEPTIC TANK ADD 3000 GAL DUAL COMPARTMENT SEPTIC TANK/PUMP CHAMBER LEACHING: 990 GPD / (.74) = 1338 SF REQUIRED 30' X 45' = 1350 SF OK 1350 SF X .74 = 999 GPD OK USE A 30' X 45' PIPE AND STONE LEACHING FIELD APPROVED , MA DATE BOARD OF HEALTH BENCHMARK: MAGNETIC NAIL SET=5.1' NAVD88 PROPOSED BARN CONNECTION 5.0't FOUNDATION BARN 05 PRECAST H-10 RISERS (TYP.) 2'0 U TEE "EXISTING TEE SEPTIC TANK GAS BAFFLE .. EXIST. SEPTIC TANK *5.7' SYSTEM PROFILE (NOT TO SCALE) MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW PROVIDE INSPECTION PORTS TO PROVIDE MIN. 20" DIAM. WATERTIGHT GRADE WITHIN 3" OF FINISH GRADE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2% SLOPE \ FILTER FABRIC MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 8 4' TOP 7.62' FINISHED GRADE- 4" LOAM &SEED 17.25' NOTE: 2" MIN. WALL PROP. TEE THICKNESS REQUIRED CLEAN FILL 4"OSCH40 PVC PIPES LEVEL 1ST 2'4• PERFORATED PVC 5' O.C. S=0.005 TO 3000 GAL H-20 3/4"-1-1/2" DOUBLE WASHED 10" 9"STONE LEACHING FIELD TEE SEPTIC TANK/PUMP CHAMBER 0 0 0 .0 •o. 0 LEVEL BOTTOM COMBINATION o000006"0000 �_0"0-0 0,0_ SEE DETAIL BELOW 7.52' 7.35' °000000000000000000000060000000000000000o0ooc WATER -TEST D'BOX FOR LEVELNESS 0000000�0000000000000000000000000000000000000 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) ( 36 % SLOPE) (1 % SLOPE) SEPTIC TANK/ LOW PROFILE 6' PUMP CHAMBER 29' D' BOX 12' 72' ( 2 % SLOPE) BUOYANCY CALCS: H-20 3000 GAL. ST WEIGHS 36,000 LBS 2.96' x 17.0 x 7.0 X 62.4 = 21,979 LBS UP (OK) PRECAST H-10 RISERS (TYP.) 2'0 3.54' ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 3.54' SEPARATE CIRCUIT FROM PUMP ZABEL FILTER FLOAT SWITCH ALARM ON (A100) SETTINGS: OUTLET TEE W/EXTENSION PUMP ON 5" WORKING RANGE 6' 7„ PUMP OFF 14" LEACHING FACILITY 2% MIN. SLOPE OVER SYSTEM ` I � 4" LOAM &SEED 30"f I CAP STONE UNITS / " x 5 1/ 21 4' " COVER -111 II _ Fiberglass 9 -111 - Pins -111=11_-_ = Ili AS 5'MIN. 30" MAX 6„ VARIES PEASTONE COARSE SAND BACKFILL AGAINST WALL 40 MIL LINER FROM TOP PEASTONE/WALL " TO 12" BELOW GRADE KEYSTONE OR EQUAL RETAINING WALL UNITS 18"X8" SET WITH 1" BATTER PER ROW 45.0' FIBERGLASS PINS REQ. 6"X30" Crushed Rock or Unreinforced Concrete Leveling Pad req. RETAINING WALL CROSS SECTION 24"0 CAST IRON COVERS TO GRADE / \ 1000 GAL.+ RESERVE / i PROVIDE QUICK DISCONNECT FOR PUMP NO LOW POINTS j7HOLES " PRESSURE LINE19" TEERAIN BACK MIN. 1000 GAL.THIS SIDEM 4 OF BAFFLESUBMERSIBLE 4/10 HP PUMP SYSTEM (OR EQUAL) 000000 0000 000�0000 3000 GAL. SEPTIC TANK/ 6" BAFFLE PUMP CHAMBER COMBINATION (NOT TO SCALE) 6.5' 6"DEPTH MIN BELOW INV. 7.0' 1.5' ASSUMED GROUNDWATER ELEVATION NOTES .0-7.0' 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. ���ZH OF MgSs9cS DANIELA. �N o OJALA CIVIL A No.465012 �G S T ESL 081ONAL E' OF Mgss9c DANIEL ties A. OJALA q No. 40980 P q�GFfSS�0� N� S U Raj G-W ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 0' MARCH 2O18 L� DATE DANIEL A. OJALA, P.E., P.L.S. a s� l o� low Q 0 �� Lewis 0 0� pond Lewis Bay Coke �d god Powers Ro°d Locus Nantucket G�eot Sound LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 14 PARCEL 11 LOCUS IS WITHIN FEMA FLOOD ZONE AE (100 YEAR FLOOD HAZARD AREA - EL. 11) AS SHOWN ON COMMUNITY PANEL #25001CO588J DATED 7/16/2014 ZONING SUMMARY ZONING DISTRICT: R-25 RESIDENTIAL DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% m 45" TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE # 13871 WITNESS: AMY VON HONE, RS DATE: 4/4/2018 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. F-o -1 ELEV. 4 79 Off7, FI LL A LS 48" 1OYR 2/1 3, C M/FS 1OYR 7/4 PEF , OF DATE: APRIL 25, 2018 REV: JULY 6, 2018 (DESIGN FLOW, PUMP CHAMBER) Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 fax 508-362-9880 downcope.com down cope eagiaeefiag, iac. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 JOH NO.=3336n . F'n301 18-087 JAYASHANKAR.DWG