HomeMy WebLinkAboutPhysiotherapy Center - Proposed 1st Floor Renovation0 I I 0 00 I 0 14'-6" SANITARY WASTE STORAGE LDECK-i IN ELECT. PANEL CORR. D 23-1 107 I% INDUSTRIAL REHAB. 106 957 SF I I� L STAFF LOCKERS 4'-9" 5'-0" 9'-59/16>, - 111 UP 1R u S TA F;r vl �-- CORR. TOILE�" _ 111 121 -Ji 40 SF P.A_TI E 0 TOILET -- — H '�� 112 N 23'-9y2" JAN. 110 30 F CL. - 110 112 N MEDICAL RECORD / 40 SF SUPPLY/EQUIPMENT STORAGE UP ELECT. 107 PANEL LDECK-i 53'-5" TREATMENT PATIENT `11 ISOILED CORR. CUBICLE TOILET jUTILITY 122 �a 113 8'-913�6 6'_p" 3'-111y6 3' a as 20 SF 108 109 122 CLEAN CLEAN �9 F CLEAN » F- -ROOF UTILITY UTILITY 00 UTILITY DRAIN STORAGE TREATMENT TREATMENT STORAG — — — STORAG 1o9 -I PIPE 0 SIN W/ CUBICLE CUBICLE COUNTER & 114 L - --- CAB. 70 SF 0 S a LSINK CURTAIN W / COUNTER g�UP - -ALIGN WALL WITH PATIENT LOCKERS CAB. COLUMN BOTTLED WATER CURTAIN _ DISPENSER 1:12 SLOPE 0 RAMP UP 0 20' — 0" UP -- PATIENT LOCKERS ROOF DRAIN PIPE O I BOTTLED WATER DISPENSER n wHEE� CHAIR STORAGE AREA - CURTAIN CURTAIN O CURTAIN— N M .O CLEAN CLEAN CLEAN UTILITY UTILITY UTILITY STORAGE STORAGE STORAGE TREATMENT 1 CUBICLE/ TREATMENT TREATMENT HANDICAPPED CUBICLE CUBICLE DRESSING AREA 1 18 1 00 117 85 SF 85 SF 98 SF 8'-2y4„ 8 —2y4 9 —8y2 COUNTER @ 42" AFF 120 COUNTER @ 36" AFF ENTRANCE - 101 147 S M ALL EXIST. EXTERIOR DOORS TO REMAIN, TYP . STAFF AREA/ MULTIPURPOSE RM. i2o � 182 SFi 16'-11" RAMP PROPOSED FLOOR PLAN z 0 9' — 8y2" EXIST. RAMP TO REMAIN GYM AREA 116 1545 S 54'-6" Al FO(JIPMFNT SCHEDULE TYPE QUANTITY DESCRIPTION A 2 ULTRASOUND 17"x18" - B 1 REBOUNDER 48"x44" C 2 KEISER KNEE 41 "x29" D 1 MULTI-HIP_�40"x42D E 1 STAIR MASTER 31 "x4O" F 1 KEISER UPPER BACK 34"x46" G 1 KEISER CHEST PRESS 40"x45" H 1 TREAD MILL 30"x68" J 1 - STATIONARY BIKE (25%46"° __ K 1 LOW MAT TABLE 48"x72" L 1 TOTAL GYM 125"x3O" M 1 COLD PACK 15%17" N 1 HOT PACK 43%15" _ P 1 1 E-STIMULATOR 16"x22" 0a 0a O 00 00 u O O O O O O O O O ALL EXIST. WINDOWS I i I TO REMAIN, PROVIDE NEW PLEXIGLASS PANELS @ MIN. 5'-0" AFF © ALL DECK WINDOWS IN GYM AREA, SEE DETAIL 6, M ATCH LI N E SEE SH T. A 1.2b II I II 40'-7" REVISED FOR D.P.H. REVIEW 7 NOV. '03 ISSUED FOR D.P.H. REVIEW 20 AUG. '03 REVISED 18 JULY '03 SUBMITTED FOR REVIEW 17 JUNE '03 Revisions: Date: PHYSIOTHERAPY CENTER RENOVATION 316 MAIN STREET, WEST YARMOUTH, MA 02673 ,.a-1 lz 1U� PROPOSED FIRST FLOOR PLAN S.A. ARCHITECTURE Architecture, Planning, Interior Design 35A Cranberry Highway / P.O.Box 1988 Orleans, MA 02653 Tel/Fax: (508) 240-5597 1/4"=1'-0" Scale: 7 NOVEMBER 2003 A 1 .2a Date: