HomeMy WebLinkAboutEngineer Plan*NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. 10' min. from - Existing Foundation house to septic tank TOP OF FOUNDATION = ELEV 10000 (Assumed) Septic tank covers must be within 6 im of finished grade /- Grade over Septic Tank - 99.00 S - 002 NEW '- S=o.o1 or Great« Fxtc_i, PIPE C? 0 1,500 GAL. 30' ------ FROM EXIST, F"DATION rn SEPTIC TANK m N 0- ed4 rn i II H.-10 II CONCRETE FULL FOUNDAT o i--r.--.�- .. _ 4) 4) i SYSTEM PROFILE 6 In of 3/4- 1 1/2 C compacted stone i Not to Scale - NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN 6" BELOW GRADE PERCOLATION TEST Date of Percolation Test: OCTOBER 31, 2005 Test Performed By CARMEN E. SHAY, R.S., C.S.E. Results Witnessed By: AMY VON HONE, R.S. (YARMOUTH B.O.H.) EXCAVATOR: Shay Env- Svcs. Percolation Rate. Less Than 2 MPI ® 32" Test Hole No. 1 DEPTH SOILS ELEV.'' _0 - - - 99.00 Loamy Sand 10 YR 3/7 0'-10, As 98.151 Loamy Sand 10 YR 5/6 10"- 32" Be 96.33; --- Medium/Fine Sand 2.5 Y 7/3 32'- 106 C, 9Q.17 Silt Loom 2.5 Y 6/2 106"- 11 C± 89.17 Medium Sand i 2.5 Y 7/4 118"- 138 � 87.50 i, Perc #1 Depth to Perc: 36" to 54" Perc Rate= 2 MPI Groundwater Not Observed No Observed ESHWT ADJUSTED H2O Elev. = None i D-BOX cover must be within 6 in. of finished grade Grade over D-Bo■ - 99.00 Grade over SAS - 99.00 3-24' DIAM-ACCESS MANHOLES To, -6'__. NLLI INLET OLITI E.T p THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SHALL BE RAISED TO WITHIN 6" OF FINISHED GRADE. y�STEEL REINFORCED PRECAST CONCRETE INSTALL TUF - TITS GAS BAFFLES OR EQUALS PLAN VIEW ON ALL OUTLET TEE ENDS 3-24' REMOVABLE COVERS \ I 4- 3' min. dearance INLET IN LE e min. -12' -In. inlet to outlet s• „�ti j Liquid laud-- - OUTLET - EQ 1 �e :.o ,♦ i f J 7• 10-0 - CROSS SECTION END -SECTION TYPICAL (H-10 LOADING) 1500 GALLON SEPTIC TANK NOT TO SCALE May Substitite for Polyethylene Tank - H-10 Equivalent Design Calculations i Number of Bedrooms: 3 Equivalent to 330 Gal./Day (330 Gal./Day Min. per Title V) Garbage Grinder: No Leaching Capacity Proposed: 330 Gal /Day Minimum (Min Per Title V) Septic Tank - 2 x 330 Col./Day = 660 USE NEW 1,500 GAL. Septic Tank. SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch Bottom Area: 0.74 gal/sq. ft. x 372.5 sq. ft. = 275.65 gallons Sidewall Area: 0.74 gal./sq. ft. x 78.72 sq. ft. = 58.25 gallons Providing: = 333.90 gallons Use: (5) INFILTRATOR HIGH CAPACITY H-20 UNITS, HAVING A 0.BS (10 INCHES) EFFECTIVE DEPTH, TO BE USED MATH 3.5' OF WASHED STONE ON THE SIDES, AND 3.5' OF WASHED STONE I ON THE ENDS. NO STONE UNDER. 3 HOLE H-10 ST BOX �01_ M o � 5' c0 u1 L rn � N N i i o u o 0 i i c c 6 in.of 3/4'-1 1/2' compacted stone SECTION A -A PROFILE VIEW OF ADDITION TO LEACHING SYSTEM 3' Maximum Cover --Top OF System- El". -96.00 1 /1-10'• EHectivw Depth 3" of 1/8' - 1/2' Washed Peastone 3/4' to 1 1/2 " Washed Crushed Stone 4- PVC (CAPPED) INSPECTION PORT To BE \ INSTALLED AM TO BE WTHN 6" OF GRADE ALL OUTLET PIPES FROM THE DISTRIBUTION BOX SNAIL BE SET LEVEL FOR AT LEAST 2 FT. - PLAN SECTION 12' ---V. ICONCRETE COVER 3 - 5' OUTLET KNOCKOUTS OUTLET 1,75 CROSS-SECTION k 11 ARAK to N N a' : 3 HOLE H-10 DISTRIBUTION BOX - u' 4 - 3L25' --- y ISU• NOT TO SCALE �No « ' a' N • II 1 �t j 3.5' -- 37.25' Effective Length 0:h! Panl llNar: B .ancaa, t1 7 S N3vtEi > 3.5' A, u =3,'� ; SOIL ABSORPTION SYSTEM (SAS) GENERAL NOTES 10 EPFecttve vldth INFILTATR❑R HIGH CAPACITY (H-20 LOADING)/ GE❑RGE ❑'BRIEN _ 1. Contractor is responsible for Digsafe notification, Verification of Utilities 0 0 �� r � (OR EQUIVALENT) Not to Scale and protection of all underground utilities and pipes. n 2. The septic tank and distribution box shall be set z 1'' Bottom of Test Hole I Elev-87.50 '71 if `� 1 NOTE: OVERALL HEIGHT OF INFILTRATOR IS 18" /EFFECTIVE HEIGHT IS 10" level on 6" of 3/4"- 1 1 /2" stone. Groundwater Observed - NONE OBSERVED ------------- ----------------------- - 3. Backfill should be clean sand or grovel with no ---- stones over 3" in size. N/F JOHN H. STETSON Failed - -- 0' 10 85.00' 4. This system is subject to inspection during installation by Carmen E. Shay - Environmental Services, Inc. 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and I ocal Regulations. 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in our design installation must halt & immediate notification be made to Carmen E. Shay - Environmental Services, Inc. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install Tuf- Tite gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is Connected to ALL OF The Residence and Abutting Properties Within 150 Feet. THE PROPERTY LINES ARE APPROXIMATE AND COMPILED FROM THE SURVEY PLAN GENERATED BY HENRY M. TUOMINEN, LAND SURVEYOR, OF HYANNIS, MA ENTITLED "SUBDIVISION PLAN OF LAND OF NICKERSON & HOLWAY, INC." JL IN S. YARMOUTH, MA, DATED MAY 7, 1958 AND PLAN BK 142 PG 143 /�--- AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN IT SHOULD BE USED FOR NO PURPOSE OTHER THAN THE SEPTIC SYSTEM INSTALLATION. l EXISTING CESSPOOLS TO BE PUMPED OUT AND REMOVED TO FACILITATE �T NEW SEPTIC SYSTEM INSTALLATION. NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE ; ,/ FROM THE EXISTING CESSPOOLS TO BE DISPOSED VV P R BOARD OF HEALTH SPECIFICATIONS T-«,•5,:;�i :.. .`: D-Box OF AS E NEW 1500 GAL. SEPTICTANK THERE ARE NO WETLANDS ARE PRESENT WITHIN 200' OF THE PROPERTY KD ,20' OJr -_-- - - Failed\\ ASSESSORS MAP 50 PARCEL 84 Failed Cesspool \ 1 Cesspool DECK j I EXIST. GARAGE LOT # 14 N - LOT # 12 Cb F I EXISTING Cb O 05 3 BEDROOM05 HOUSE I '` I #�l I I I -----c r- o 1' i EXIST. rr I I I I 98--- -------LOT #13 DRIVEWAY �' Q ----� Cn 8,500 Square Feet -+/- I I I I I \ 85.00'00 \1 I I I \\ i ! , ----------------------------------------------------- J UPI TFR LA NE' (40 FOOT RIGHT OF WAY) 0 20 40 50 SCALE: 1 "=20' r----­-- - NOV 0 9 2005 104X1 X 104.46 PL 96P ------97 DENOTES PROPOSED SPOT GRADE DENOTES EXISTING SPOT GRADE PROPERTY LINE PROPOSED CONTOUR EXISTING CONTOUR DEEP TEST HOLE & PERCOLATION TEST LOCATION 6 FOOT STOCKADE FENCE PLOT PLAN PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR Mr. Kevin Hines/Florence Geiselman Trus AT #11 JUPITER LANE YARMOUTH, MA OF LSERT T. m 1 PREPARED BY: CARNEX E. S'HA Y S + ENVIRONMENTAL SERVICES, INC. P.O. BOX 627 EAST FALMOUTH, MA 02536 TEL/FAX : 508-539-7966 SCALE: 1 "=20' DRAWN BY: CES DA PROJECT#SD828 FILENAME: SD828PP.DWG TE: NOVEMBER 7, 2005 SHEET 1 OF 1