Loading...
HomeMy WebLinkAboutReview Checklist otP TOWN OF YARMOUTH . '; SEWAGE PLAN REVIEW CHECKLIST Location: A.M. <57) Lot P Zone of Contribution: In Out `P Acreage i Commercial: Residential: _) j Street: (jc.-40161 �-1kVillage: )c- 4'/'- Floor Plan: L. r #Bedroom Owner: 4c7S/ ,c /ia /266t Installer: /6-6,--U4- Address: Phone: 4 W= `.'2 /Z) Phone: Builder: Engineer: ( q44 i Address: 7- Phone: S - 776 Phone: %l/7L i' ie' C /o 'ti i t N/AYES i NO 1.Required#of copies received . 2. Date of soils exam and percolation test not older than 2 years (..� 3. 4-5 ft of naturally occurring pervious material, above water table t. 4.Foundation 2 ft above high point of road H.P.:• Fnd: Var.: C./ 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: l// 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: \/ 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: �---- 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: L/ 13.Uses adjustment for maximum high groundwater Var.: �/' 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: i,/ 15. System not in top or subsoil(A,B horizons)or 5'removal L/ 16.Proposed contours are suitable '`,/ 17. System meets slope requirements-min. 1/8", 1/4"preferred l� 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee `-� 20. Sewage is under 10,000 gpd for parcel t/ 21.No garbage disposal L/ 22. System adequately sized for its intended use / 23.Minimum 6"stone or compacted below tank and dbox `1 24.Manhole covers within 6"of grade,pump chamber cover to grade L_/ 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes - 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking ,- 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater `/` 34. Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: VLA 6/03/03