HomeMy WebLinkAbout23-A084 29 Setucket S101WOOD 1. ALL STRUCTURAL LUMBER AND THEIR CONNECTIONS SHALL CONFORM TO THE LATEST EDITION OF NFPA NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION AND SUPPLEMENT 'DESIGN VALUES FOR WOOD CONSTRUCTION" AS WELL AS THE AMERICAN FOREST AND PAPER ASSOCIATION GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE AND TWO FAMILY DWELLINGS. 100 MPH EXPOSURE (780 CMR 5301.2.1.1) OR THE COMMONWEALTH OF MASSACHUSETTS CHECKLIST IN THE APPENDIX 780 CMR 120 P 2. UNLESS OTHERWISE NOTED ALL SAWN LUMBER FRAMING MEMBERS, JOIST, RAFTERS, STUDS, LINTELS, PLATES, SHALL BE SPRUCE-PINEFIR NO.2 OR BETTER, WITH THE FOLLOWING MINIMUM PROPERTIES: Fb-875 PSI, Fr 70PSI E=1,400.00 PSI 3. ALL "MICROLAM" AND "VL" VERSALAM MEMBERS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: E --2,000.000 PSI Fb=2,950 PSI Fv--285 PSI 4. ALL "PARALLAM PSL" MEMBERS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: E=2,000.000 PSI Fb 2,900 PSI Fv--290 PSI Fc0--2,900 PSI 5. WOOD SILLS SUPPORTED ON CONCRETE OR CONCRETE MASONRY UNDER ALL INTERIOR OR EXTERIOR WALLS, AND ALL MEMBERS EXPOSED TO WEATHER OR MOISTURE, SHALL BE SOUTHERN PINE NO. 2 OR BETTER, PRESERVATIVE TREATED IN ACCORDANCE WITH THE "AMERICAN WOOD PRESERVERS ASSOCIATIONS STANDARD Cl." 6. ALL STRUCTURAL LUMBER SHALL BE STAMPED IN ACCORDANCE THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION'S "CONSTRUCTION MANUAL". 7. UNLESS OTHERWISE NOTED, ALL NAILING AND FASTENING SHALL BE IN ACCORDANCE WITH THE FASTENING SCHEDULE LISTED IN TABLE 2305.2 OF THE MASSACHUSETTS STATE BUILDING CODE EIGHTH EDITION. 8. ADDITIONAL FLOOR JOISTS SHALL BE PROVIDED UNDER ALL PARTITIONS OVER 4'-0" LONG WHICH RUN PARALLEL TO THE SPAN OF THE FLOOR. 9. ADDITIONAL FLOOR JOISTS SHALL BE PROVIDED UNDER BATH TUBS. 10. PROVIDE CONTINUOUS 2X SOLID BLOCKING MATCHING THE STUD SIZE, BETWEEN STUDS AT STUD MID -HEIGHT. 11. UNLESS NOTED OTHERWISE, PROVIDE AT MINIMUM DOUBLE STUDS UNDER ALL HEADERS, OR BUILT UP BEAMS. ADDED STUDS AND ALL POSTS SHALL CONTINUE FROM THE POINT OF LOAD APPLICATION TO THE FOUNDATION. 12. ALL POST TO BEAM CONNECTIONS SHALL HAVE METAL POST BASE AND POST CAP. Pmjeet Atlreas 29 Setucket Rd, Yarmouth Port 13. ALL FLUSH FRAMING CONNECTIONS SHALL HAVE BEAM OR JOISTS HANGERS CAPABLE TO SUPPORT THE MEMBER REACTION. cli / o- 14. ALL METAL CONNECTORS FOR WOOD CONSTRUCTION, JOISTS AND BEAM HANGERS, POST AND COLUMN CAPS AND BASES, BRIDGING, C-fta r HOEDOWNS, HURRICANE TIES, STRAPPING AND ANY OTHER METAL CONNECTORS, SHALL BE HOT -DIPPED GALVANIZED AS PER Luigy Sacramento MANUFACTURED BY "SIIAPSON STRONG -TIE COMPANY" OR EQUAL. ALL METAL CONNECTORS SHALL BE ATTACHED BY THE GENERAL CONTRACTOR AS PER MANUFACTURERS SPECIFICATIONS. NAILS SHALL BE FULLY DRIVEN IN ALL HOLES OF THE HANGERS OR ANCHORS. 15. FRAMING MEMBERS SHALL NOT BE NOTCHED, CUT OR ALTERED WITHOUT IN FIELD THE APPROVAL OF THE ENGINEER. REFER TO TYPICAL DETAILS FOR ALLOWED NOTHING AND HOLES IN 2X WOOD JOISTS.�,�" 16. UNLESS OTHERWISE NOTED ON DRAWINGS, ALL STUD WALLS SHALL -. SI _,N BE CAPPED WITH DOUBLE TOP PLATES WITH OVERLAPPING CORNERS AND INTERSECTIONS. SPLICE IN TOP PLATES SHALL BE ON TOP OF STUDS AND BE OFFSET MINIMUM 4 FEET. e 17. ALL TOP MOUNTED JOIST SHALL HAVE MNUA M 3 INCH BEARING 18. ALL EXTERIOR AND INTERIOR WALL SHEATHING SHALL BE 15/32 APA RATED SHEATHING. AT EXTERIOR WALLS USE EXPOSURE 1 PANELS AND USE EXTERIOR GRADE SHEATHING WHEN LONG CONSTRUCTION DELAYS ARE EXPECTED. PROVIDE 2X HORIZONTAL BLOCKING AT LEAST EQUAL THE SIZE OF JOIST, AT ALL UNSUPPORTED PANEL EDGES. SHEATHING SHALL BE PROPERLY FASTENED TO THE WALL STUDS, SOLE PLATES, TOP PLATES AND BLOCKING AS REQUIRED BY CODE, OR SHOWN ON DRAWINGS. PANEL JOINTS SHALL OCCUR OVER STUDS AND BLOCKING. 19. ALL ROOF SHEATHING SHALL BE 5/8" APA RATED SHEATHING EXPOSURE 1, EXCEPT USE EXTERIOR GRADE PANELS WHEN LONG CONSTRUCTION DELAYS ARE EXPECTED. APPLY PANELS WITH LONG DIMENSIONS PERPENDICULAR TO THEIR SUPPORT OVER TWO OR MORE SPANS. UNLESS OTHERWISE SHOWN ON PLANS, SHEATHING SHALL BE NAILED WITH 8D NAILS @ 6 INCHES ON CENTER AT EACH SIDE OF EDGE JOINTS, AND 8D NAILS @12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS. 20.FLOOR SHEATHING SHALL BE 3/4 INCH APA RATED EXPOSURE 1, TONGUE AND GROOVE PLYWOOD PANELS. APPLY PANELS WITH THE LONG DIMENSION PERPENDICULAR TO FLOOR JOISTS, CONTINUOUS OVER TWO OR MORE SPANS. PANELS SHALL HAVE STAGGERED END JOINTS IN EACH SUCCEEDING ROW AND SHALL BE GLUED AND NAILED TO FLOOR JOISTS AS REQUIRED BY CODE AND LEAVING 1/8 INCH SPACE BETWEEN ALL END AND EDGE JOINTS. DESIGN CRITERIA 1. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE MASSACHUSETTS BUILDING CODE, APPLICABLE LOCAL REGULATIONS AND ORDINANCES, AND ALL REFERENCED CODES. GROUND SNOW LOAD (Pg) = 50.0 PSF. FLOOR: LIVE LOAD: EXTERIOR DECK FLOOR =100 PSF RECEIVED DEAD LOAD: = 20 PSF ,IUN 0 H 7pq WIND LOAD 125 MHP (CATEGORY I) WIND EXPOSURE D D KINn�vv H AY SEISMIC Ss = 0.221 / SI = 0.071 RENOVATION SITE CLASS D PERFORMANCE CATEGORY B A S U N ROOM LATERAL LOAD RESISTING SYSTEM ORDINARY MOMENT FRAMES LIGHT GAGE SHEAR WALLS RMF=3.5/DAF=3.0 STRUTURAL NOTES B AND SITE PLAN P.Jegn IN D� m4m S101 Draw LG vwy ml Scale 24105/202319:12:37