1. ALL STRUCTURAL LUMBER AND THEIR CONNECTIONS SHALL
CONFORM
TO THE LATEST EDITION OF NFPA NATIONAL DESIGN SPECIFICATIONS
FOR WOOD CONSTRUCTION AND SUPPLEMENT 'DESIGN VALUES FOR
WOOD CONSTRUCTION" AS WELL AS THE AMERICAN FOREST AND
PAPER ASSOCIATION GUIDE TO WOOD CONSTRUCTION IN HIGH WIND
AREAS FOR ONE AND TWO FAMILY DWELLINGS. 100 MPH EXPOSURE
(780 CMR 5301.2.1.1) OR THE COMMONWEALTH OF MASSACHUSETTS
CHECKLIST IN THE APPENDIX 780 CMR 120 P
2. UNLESS OTHERWISE NOTED ALL SAWN LUMBER FRAMING
MEMBERS,
JOIST, RAFTERS, STUDS, LINTELS, PLATES, SHALL BE SPRUCE-PINEFIR
NO.2 OR BETTER, WITH THE FOLLOWING MINIMUM PROPERTIES:
Fb-875 PSI,
Fr 70PSI
E=1,400.00 PSI
3. ALL "MICROLAM" AND "VL" VERSALAM MEMBERS SHALL HAVE THE
FOLLOWING MINIMUM PROPERTIES:
E --2,000.000 PSI
Fb=2,950 PSI
Fv--285 PSI
4. ALL "PARALLAM PSL" MEMBERS SHALL HAVE THE FOLLOWING
MINIMUM PROPERTIES:
E=2,000.000 PSI
Fb 2,900 PSI
Fv--290 PSI
Fc0--2,900 PSI
5. WOOD SILLS SUPPORTED ON CONCRETE OR CONCRETE MASONRY
UNDER ALL INTERIOR OR EXTERIOR WALLS, AND ALL MEMBERS
EXPOSED TO WEATHER OR MOISTURE, SHALL BE SOUTHERN PINE NO.
2
OR BETTER, PRESERVATIVE TREATED IN ACCORDANCE WITH THE
"AMERICAN WOOD PRESERVERS ASSOCIATIONS STANDARD Cl."
6. ALL STRUCTURAL LUMBER SHALL BE STAMPED IN ACCORDANCE
THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION'S
"CONSTRUCTION MANUAL".
7. UNLESS OTHERWISE NOTED, ALL NAILING AND FASTENING SHALL
BE IN
ACCORDANCE WITH THE FASTENING SCHEDULE LISTED IN TABLE
2305.2
OF THE MASSACHUSETTS STATE BUILDING CODE EIGHTH EDITION.
8. ADDITIONAL FLOOR JOISTS SHALL BE PROVIDED UNDER ALL
PARTITIONS OVER 4'-0" LONG WHICH RUN PARALLEL TO THE SPAN OF
THE FLOOR.
9. ADDITIONAL FLOOR JOISTS SHALL BE PROVIDED UNDER BATH
TUBS.
10. PROVIDE CONTINUOUS 2X SOLID BLOCKING MATCHING THE STUD
SIZE, BETWEEN STUDS AT STUD MID -HEIGHT.
11. UNLESS NOTED OTHERWISE, PROVIDE AT MINIMUM DOUBLE
STUDS
UNDER ALL HEADERS, OR BUILT UP BEAMS. ADDED STUDS AND ALL
POSTS SHALL CONTINUE FROM THE POINT OF LOAD APPLICATION TO
THE FOUNDATION.
12. ALL POST TO BEAM CONNECTIONS SHALL HAVE METAL POST BASE
AND POST CAP.
Pmjeet
Atlreas
29 Setucket Rd, Yarmouth Port
13. ALL FLUSH FRAMING CONNECTIONS SHALL HAVE BEAM OR JOISTS
HANGERS CAPABLE TO SUPPORT THE MEMBER REACTION. cli / o-
14. ALL METAL CONNECTORS FOR WOOD CONSTRUCTION, JOISTS AND
BEAM HANGERS, POST AND COLUMN CAPS AND BASES, BRIDGING,
C-fta r
HOEDOWNS, HURRICANE TIES, STRAPPING AND ANY OTHER METAL
CONNECTORS, SHALL BE HOT -DIPPED GALVANIZED AS PER
Luigy Sacramento
MANUFACTURED BY "SIIAPSON STRONG -TIE COMPANY" OR EQUAL.
ALL METAL CONNECTORS SHALL BE ATTACHED BY THE GENERAL
CONTRACTOR AS PER MANUFACTURERS SPECIFICATIONS. NAILS SHALL
BE FULLY DRIVEN IN ALL HOLES OF THE HANGERS OR ANCHORS.
15. FRAMING MEMBERS SHALL NOT BE NOTCHED, CUT OR ALTERED
WITHOUT IN FIELD THE APPROVAL OF THE ENGINEER. REFER TO
TYPICAL DETAILS FOR ALLOWED NOTHING AND HOLES IN 2X WOOD
JOISTS.�,�"
16. UNLESS OTHERWISE NOTED ON DRAWINGS, ALL STUD WALLS SHALL
-. SI _,N
BE CAPPED WITH DOUBLE TOP PLATES WITH OVERLAPPING CORNERS
AND INTERSECTIONS. SPLICE IN TOP PLATES SHALL BE ON TOP OF
STUDS AND BE OFFSET MINIMUM 4 FEET.
e
17. ALL TOP MOUNTED JOIST SHALL HAVE MNUA M 3 INCH BEARING
18. ALL EXTERIOR AND INTERIOR WALL SHEATHING SHALL BE 15/32 APA
RATED SHEATHING. AT EXTERIOR WALLS USE EXPOSURE 1 PANELS AND
USE EXTERIOR GRADE SHEATHING WHEN LONG CONSTRUCTION
DELAYS ARE EXPECTED. PROVIDE 2X HORIZONTAL BLOCKING AT LEAST
EQUAL THE SIZE OF JOIST, AT ALL UNSUPPORTED PANEL EDGES.
SHEATHING SHALL BE PROPERLY FASTENED TO THE WALL STUDS, SOLE
PLATES, TOP PLATES AND BLOCKING AS REQUIRED BY CODE, OR
SHOWN ON DRAWINGS. PANEL JOINTS SHALL OCCUR OVER STUDS AND
BLOCKING.
19. ALL ROOF SHEATHING SHALL BE 5/8" APA RATED SHEATHING
EXPOSURE 1, EXCEPT USE EXTERIOR GRADE PANELS WHEN LONG
CONSTRUCTION DELAYS ARE EXPECTED. APPLY PANELS WITH LONG
DIMENSIONS PERPENDICULAR TO THEIR SUPPORT OVER TWO OR
MORE SPANS. UNLESS OTHERWISE SHOWN ON PLANS, SHEATHING
SHALL BE NAILED WITH 8D NAILS @ 6 INCHES ON CENTER AT EACH
SIDE OF EDGE JOINTS, AND 8D NAILS @12 INCHES ON CENTER AT
INTERMEDIATE SUPPORTS.
20.FLOOR SHEATHING SHALL BE 3/4 INCH APA RATED EXPOSURE 1,
TONGUE AND GROOVE PLYWOOD PANELS. APPLY PANELS WITH THE
LONG DIMENSION PERPENDICULAR TO FLOOR JOISTS, CONTINUOUS
OVER TWO OR MORE SPANS. PANELS SHALL HAVE STAGGERED END
JOINTS IN EACH SUCCEEDING ROW AND SHALL BE GLUED AND NAILED
TO FLOOR JOISTS AS REQUIRED BY CODE AND LEAVING 1/8 INCH SPACE
BETWEEN ALL END AND EDGE JOINTS.
DESIGN CRITERIA
1. THIS STRUCTURE HAS BEEN DESIGNED IN
ACCORDANCE WITH THE
MASSACHUSETTS BUILDING CODE, APPLICABLE LOCAL
REGULATIONS AND ORDINANCES, AND ALL REFERENCED
CODES.
GROUND SNOW LOAD (Pg) = 50.0 PSF.
FLOOR:
LIVE LOAD: EXTERIOR DECK FLOOR =100 PSF
RECEIVED
DEAD LOAD: = 20 PSF
,IUN 0 H 7pq
WIND LOAD 125 MHP (CATEGORY I)
WIND EXPOSURE D
D KINn�vv H AY
SEISMIC
Ss = 0.221 / SI = 0.071
RENOVATION
SITE CLASS D
PERFORMANCE CATEGORY B
A S U N ROOM
LATERAL LOAD RESISTING SYSTEM
ORDINARY MOMENT FRAMES
LIGHT GAGE SHEAR WALLS
RMF=3.5/DAF=3.0
STRUTURAL NOTES B AND
SITE PLAN
P.Jegn IN
D� m4m S101