Loading...
HomeMy WebLinkAboutReview Checklist, TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 7 Lot 4�sj Zone of Contribution: In_ Out 1 creage b,oeO± I , / Commerc' • R::: t : 1;� Street: Village: 4?) 1-t' �',,, c) P..6 Floor PI : N�te N # B p1 Owner: Installer •: Address: �' �c' �'- ' , C' r'S Phone: Phone: Builder:Address: Engineer: ft c,; a) ec � , ,t), (Joii-/Z. --c Phone: Phone: N/A YES NO 1. Required#of copies received ...---- 2. Date of soils exam and percolation test not older than 2 years 4---- 3. 4-5 ft of naturally occurring pervious material,above water table - 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: - 5. Water line 10 ft from septic components Var.: c/6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: e/ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 . •m drinking well/25 ft irrigatio Var.: -5 11.Tank/leaching minimu jii from property line Va .. 1' ._5 ‘ !i t . 12. System meets all other set\ .ack requirements V .: f 13. Uses adjustme t for maximum high groundwater Var.: / 14. Leaching s -5 above adj. water or bottom of test hole Var.`/'! - t f''` l I 15. System not in op or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable k----- 17. System meets slope requirements-min. 1/8", %"preferred ;/ __18. System meets breakout requirements PVC liner: Wall: / 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal I 22_ System adequately sized for its intended use f 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field - 26. Electrical permit for pump chamber/Separate meter for duplexes ,.--- 27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size --- 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber /' 31. Engineer to inspect and certify soils: wall: commercial: ,i--- 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 1 34.Title V Application and permit fee,installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd I J 37. Check area lots for groundwater/Label groundwater in Assessor's Map I / I Plan reviewed by a.r-ate, Cc_- 6 ••/ 2_3 co:o;