HomeMy WebLinkAboutEngineer PlanEXISTING S.A.S.
TO BE REMOVED WITHIN PROP.
SEPTIC FOOTPRINT, OTHERWISE
ABANDONED —SEE NOTE I I
20
PROPOSED S.A.S.
3 ROWS OF 3, CULTEC
C4—HD FIELD DRAIN UNITS
FLOOR PLAN
Permit valid for REPAIR OF SEPTIC
t "SLY, due to State and Local septic
lht,ard of Health review and approval is re4
any future additions/renovationslatters
sewage facilities and/or structures/dwelling.
Yarmouth Health Department
APPROVED
99'1
99.7
99.36
a
99.21 b
6 •I
Date
RECEIVED
MAY 2 6 2023
HEALTH DEPT
OWNER OF RECORD
LENA, KATE
33 WEDGEMERE ROAD
WEST YARMOUTH, MA 02673
FEMA FLOOD DESIGNATION
MAP NUMBER: 25001CO586J
EFFECTIVE DATE: JULY 16, 2014
NON HAZARD
LEGEND
x 6.32 EXISTING SPOT GRADE
-- 7 EXISTING CONTOUR
gyl EXISTING WATER SERVICE
ianceC EXISTING GAS SERVICE
OVERHEAD WIRES
TEST PIT
Q} BENCHMARK
ea
aj
o�
�c S�an�kano 0
c,.
tpa o
LOCUS MAP
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW:
—310 CMR 15.405(1)(a)&(h): CONTENTS OF LOCAL UPGRADE APPROVAL
1) A 4' variance, S.A.S. to property line (rear), for a 6' setback.
2) A 4' variance, S.A.S. to property line (side), for a 6' setback.
3) A 1' reduction to the required separation between adjusted
high groundwater and bottom of S.A.S., for 4' of separation.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ELEVATIONS ARE BASED ON NAVD88t.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO ABUTTING WELLS WITHIN 100' OF THE PROPOSED S.A.S..
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING
SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN.
14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY.
MAP ID: 49-43
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
33 WEDGEMERE ROAD, WEST YARMOUTH, MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673
Engineers: Surveyors: SCALE DRAWN JOB. NO.
Engineering Works, Inc. Richard J. Mood PLS 1 "=20' P.T.M. 159-23
12 West Crossfieid Road 12 Settlers Path DATE
Forestdale, MA 02644 Sandwich, MA 02563 CHECKED SHEET NO.
(508) 477-5313 (508) 246-6260 5/17/23 P.T.M. 1 of 2
SEPTIC TANK
INSTALL RISERS & COVERS OVER INLET &
OUTLET AND SET TO 6" OF FINISH GRADE
T.O.F.=102.1 f
-F.G. EL.=101.4t F.G. EL.=101.0f
EXISTING
N D. — I 24'I.D DIE.
TOP OF TANK=99.69
�'sTCT'irr"'
-11� O
10" 14
ADD
GAS BAFFLE
FIBERGLASS PER TITLE 5 REPORT 3/27/23
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) SEPTIC TANK & D—BOX SHALL BE SET LEVEL AND
TRUE TO GRADE ON A MECHANICALLY COMPACTED
STABLE BASE OR 6" COMPACTED GRAVEL BASE, AS
SPECIFIED IN 310 CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF—TITE, ZABEL OR EQUAL.
DESIGN CRITERIA
PROPOSED D-BOX
INSTALL RISER & WATERTIGHT
COVER SET TO 6" OF GRADE
F.G. EL.=101.0t
11
@ S=1% (MIN.) I I I I Q S=1% (MIN.)
4"SCH40 PVC 4"SCH40 PVC
I-� J 3" TO
INV.=97.80 INVERT
PROPOSED INV.=97.63
-INV.=98.6f
D-BOX INV.=97.50-
(VERIFY)
NOTE: TO PI:EVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL: 97.6
FOR A DISTANCE OF 15' AROUND THE
PERIMETER OF THE S.A.S.
PROPOSED S.A.S.
INSTALL ONE INSPECTION PORT (MIN.)
,-F.G. EL.=101.0f
,'z
INSPECTION PORT
SET 3" TO F.G. WITH
PROTECTIVE FRAME &
COVER
3 UNITS 0 8'/UNIT I 1'
LENGTH=24' GEOGRID
SOIL ABSORPTION SYSTEM (PROFILE)
ESTABLISH VEGETATIVE COVER
CULTEC NO. 410 FILTER FABRIC
BACKFILL WITH CLEAN SAND
F.G. ELEV.=101.0t
12°
TOP OF CHAMBER ELEV.=97.6
INV.ELEV.=97.50
BOTTOM ELEV.=97.25
4' OF NATURALLY OCCURRING 1' 48" (TYPICAL) SUITABLE SOILS 1'
PERVIOUS MATERIAL
4' (MIN.) ABOVE G.W. 3 ROWS O 4'/ROW=EFFECTIVE WIDTH-12'
WITH VARIANCE
ADJUSTED G.W., EL=93.1 _ S.A.S. SECTION)
BIAXIAL GEOGRID/QX1100 MANUFACTURED BY
TENSAR CORP., ATLANTA. GA . OR EQUAL
— EXTEND GEOGRID FOR 1' ON ALL SIDES
OF THE S.A.S. FOOTPRINT
— ROLL OUT OVERLAP
PERPENDICULAR TO
SEPTIC SYSTEM PROFILE ROWS &OVERLAP BY 2'
NUMBER OF BEDROOMS: 2 BEDROOMS
SOIL TEXTURAL CLASS: CLASS I
DESIGN PERCOLATION RATE: <6 MIN/IN
DAILY FLOW: 220 G.P.D.
DESIGN FLOW: 330 G.P.D.
GARBAGE GRINDER: NO
EXISTING SEPTIC TANK: 1000 GALLON CAPACITY
—FIBERGLASS
NO MENTION OF FAILURE IN
3/27/23 REPORT
PROPOSED DISTRIBUTION BOX: DB-3 (H-10)
LEACHING AREA REQUIRED: (330 GPD) = 445.9
SF
.74 GPD/SF
USE 3 ROWS OF 3 CULTEC C-4HD UNITS, NO STONE
FOR AN S.A.S. HAVING THE DIMENSIONS:
12.0' x 24.1
BOTTOM AREA:(GENERAL USE APPROVAL FOR 6.7
SF/LF)
3 UNITS x 8.0'/UNIT = 24.0
FT
3 ROWS x 24.0' x 6.7 SF/LF
= 482.4 SF
DESIGN FLOW PROVIDED: 0.70(482.4 S.F.) =
337.7 GPD
SOIL LOG
DATE: APRIL 26, 2023
SOIL EVALUATOR: ANNA WIMMER SE#14.615
WITNESS: JAY GARDNER R.S. HEALTH AGENT
ELEV. T P —1 DEPTH
101.0 A 0"
LOAMY SAND
1OC.2 10YR 4 2 91,
B
LOAMY SAND
1OYR 5/2
99.8
14"
C1
LOAMY SAND[
PERC
7'/25"
10YR 5/6
98.6
29"
C2
M—C SAND
2.5Y 6/6
93.1
ADJ GW =
101 "
91.8
STG GW —
110" _
Index Well Readings
wn w •ter• ur• �� i• ,.• a_� 2023
ea"r.eM�n uwHm m + i, v n u'
.,w , v u v v .z •.
nu.� w.. m ,,, •. u I -
wdttl•„ 1' Wl+w+l.
PERC RATE <2 MIN/IN. "Cl" HORIZON
STANDING GW @ 110"
INDEX WELL MIW-29 WATER LEVEL=7.6'
ZONE A ADJUSTMENT=1.3'
MODEL FD C-4 R STARTER
SMALL RIB
LARGE RIB
MODEL FD C-4 E MIDDLE/END
SMALL RIB
LARGE RIB
i
48"
4" DIA.
3"
8.5"
t A f
8.5'
8.0'
8.�Mg
"SMALL
0 o0 o 0 o a RIB LARGE RI
CULTEC CONTACTOR FIELD DRAIN C-4 CHAMBER STORAGE = 1.692 CF/FT
ALL CONTACTOR FIELD DRAIN C-4HD HEAVY DUTY UNITS ARE MARKED WITH A COLOR
STRIPE FORMED INTO THE PART ALONG THE LENGTH OF THE CHAMBER.
CULTEC CONTACTOR FIELD DRAIN C-4HD
CULTEC, Inc. PH: (203) 775-4416 rM
P.O. Box280 PH: (800) 4-CULTEC CULTEC Contactor® and Recharger®
878 Federal Poad FX: (203) 775-1462 a Plastic Septic and Stormwater Chambers
Brookfield. Cr 06804 USA www.cuitec.com CULTEC
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
33 WEDGEMERE ROAD, WEST YARMOUTH, MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02672
Engineers: Surveyors: SCALE DRAWN JOB. NO.
Engineering Works, Inc. Richard J. Hood PLS N.TS. P.T.M. 159-23
12 West Crossfield Road 12 Settlers Path DATE CHECKED SHEET NO.
Forestdole, MA 02644 Sandwich, MA 02563
(508) 477-5313 (508) 246-6260 5/17/23 P.T.M. 2 of 2