HomeMy WebLinkAboutBLDE-23-004497 �\``� Commonwealth of Official Use Only E Massachusetts Permit No. BLDE-23-004497 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/14/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 9 BAKER AVE Owner or Tenant MARY HAUSER Telephone No. Owner's Address 9 BAKER AVE,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(11 Panels 4.29 KW)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. ,Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. To No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained ,Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Eauivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Euuivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Qt2 Iy (1- 3 up) Please email permit to ea errmits@sunrun.com ` Commonwealth o1 VI C E I V E p Official Use Only C. -IRi— ' 2S a tment o`.Jire S �=- - � � FEB —'-t_�— 21�acc a y and Fee Checked BOARD OF FIRE PREVENTION IIQNS__ [Rev. /07 (leave blank) BUILDING DEPA APPLICATION FOR PERMIT ECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 02/09/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)9 Baker Ave Owner or Tenant Mary Hauser Telephone No. (617) 999-0077 Owner's Address 9 Baker Ave Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps / Volts Overhead ® Und rdr-�g I I No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar. 11 solar panels 4.29 Kw DC. NO ESS. NO STRUCTURAL Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Municipal P Local❑ Connection ❑ Other No.of Dryers Heating Appliances KVV SecuriNo o SD vices or Equivalent No.of Water No.KW No.of No.of Data Wiring: Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $5646 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature I4 LIC.NO.:21136 A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519 Address: 695 Myles Standish Blvd. Taunton. MA 02780 Alt.Tel.No.: 978 793-7881 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ Please email permit to eastmapermits@sunrun.com • SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE.4290W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780 2015 IRC/IBC/IEBC), SE SERVICE ENTRANCE •MODULES:(11)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE3800H-USMN MP MAIN PANEL •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. PV-3.0 LAYOUT PV-4.0 ELECTRICAL gp SUB-PANEL •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-5.0 SIGNAGE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY LC PV LOAD CENTER GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. CDSUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PM PV PRODUCTION METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II INV INVERTER(S) MODULES,ARE CLASS A FIRE RATED. •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL AC AC DISCONNECT(S) CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ED •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690,31(G). DC DC DISCONNECT(S) O •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. CB IQ COMBINER BOX •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. ABBREVIATIONS •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. 7 • INTERIOR EQUIPMENT A AMPERE L J SHOWN AS DASHED •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE AC ALTERNATING CURRENT LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION s u n r u n AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT (E) EXISTING FLUSH ATTIC VENT VICINITY MAP #180120 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT _lSa[elT1 PV MYLES BTANDISH BLVD.TAUNTON,MA.0]700.]331 PHONED EXT EXTERIOR METAL PIPE VENT FAX C CUSTOMER RESIDENCE: INT INTERIOR - MOP MAIN SERVICE PANEL T-VENT �StOII MARY HAUSER 9 BAKER AVE,YARMOUTH,MA, (NI NEW SATELLITE DISH 02673 NTS NOT TO SCALE oc ON CENTER FIRE SETBACKS TEL.(617)999-O077 APN:YARM-000045-000004 PRE-FAB PRE-FABRICATED e 9 Baker Ave, PROJECT NUMBER: , .. f PSF POUNDS PER SQUARE FOOT k HARDSCAPE PV PHOTOVOLTAIC West Yarmouth, MA... 223R-009HAUS RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE DESIGNER: (415)580-6920 ex3 TL TRANSFORMERLESS SCALE:NTS E ODETTE MANIRAMBONA TYP TYPICAL SOLAR MODULES I D SHEET REV NAME DATE COVER SHEET v VOLTS COMMENTS W WATTS REV:A 2/8/2023 LAN LANDSCAPE L TOPSPEED POR PORTRAIT MOUNT PAGE pV 1.0 rempere verOon-aa.87 LE- 2-3-- C LLc? 7 • • SITE PLAN-SCALE=1/16"=1'-0" IV" 8.4KERAVE a /° L7 P[ -------7 s' (N)ARRAY AR-02 / a / \L • (E)RESIDENCE / (N)ARRAY AR-01 / g .a e sunrun rM� #180,20 ®�®� SOS MVLEB STAND.BLVD,TAUMCN,MA 03]00.]331 PHONE 0 L le (E)DETACHED FAX L. / STRUCTURE A CUSTOMER RESIDENCE: MARY HAUSER 9 BAKER AVE,YARMOUTH,MA, Pt 02673 TEL.(617)G99-0077 \ RRA TRUE PV AREA PITCHY AZIM (SOFT) Pl- AR-01 30° 195° 103.5 APN:YARM-000045-000004 PROJECT NUMBER: M \ AR-02 26° 15° 124.2 223R-009HAUS Pt DESIGNER: (415)580-6920 ex3 \/ ODETTE MANIRAMBONA SHEET SITE PLAN REV:A 2/8/2023 PAGE PV_2.O TompNM1 wnlon_40.B7 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Span Spacing Edge Overhang Overhang SNOW LOAD:30 PSF - AR-01 COMP SHINGLE 1-Story 2X6 RAFTERS 12'-9" 16" TOPSPEED,SEE DETAIL SNR-DC-30004 3 WINDPEED: 1'-5" 0'-10" 140MPH3-SEC GUST. TOED S.S.LAG SCREW AR-02 COMP SHINGLETOSPEED 1-Story 2X6 RAFTERS 6'-7" 16" TOPSPEED,SEE DETAIL SNR-DC-30004 3 (4)#14 X 2.25"SS SEALING 1'-5" 0'-10" WASHER WOOD SCREWS FULLY PENETRATING THROUGH WOOD 01-AR-01-SCALE:3/16"=1'-0" DECK AZIM:195° , 9' 17'-5" —11,_il,, PITCH:30° g-1„ El r - ---`, INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED 3-7 PRIOR TO PROCEEDING W/INSTALLATION. I MOUNT NUMBER FOR LEADING DOWNSLOPE EDGE 7-I 1 SHALL MATCH REQUIREMENTS LISTED ABOVE INSTALL PER TOPSPEEDTM INSTALLATION MANUAL. CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK MOUNTS (SNR DETAIL SNR-DC-00453)WITH A MAX OVERHANG OF 6' 4'-11" -11'-8" 11'-7„ D2-AR-02-SCALE:3/16"=1'0" sunrun AZIM:15° PITCH:26° 10"-1 i 11.-7„ ,-3,-8"—, SMOLT ONL � 1H Or MASs4 #180120 -Ji �O� C'' 565 MILES STANDISH BLVD,TAUN/ON,MA,02760.7331 f VINCENT ,, PHONE 0 2-2 g MWUMVANEZA N FAX0 -O = Z milZ \ CIVIL . CUSTOMER RESIDENCE: 9,'�`y' a����`p Signed:ozmeaoz3 MARY HAUSER -`. r.NALL.V' 9 BAKER AVE,YARMOUTH,MA, 02673 wiz z z ..1 TEL.(617)999-0077 1U-11" APN:YARM-0o0045-000004 0 o PROJECT NUMBER: 223R-009HAUS DESIGNER: (415)580-6920 ex3 o _MI ODETTE MANIRAMBONA 11 SHEET LAYOUT SEE SITE PLAN FOR NORTH ARROW 13'�" REV:A 2/8/2023 PAGE PV-3.0 Temp'ete w on 4.O.87 120/240 VAC SINGLE PHASE SERVICE OMETER#: NOTE:TOTAL PV BACKFEED=20A EVERSOURCE 2288115 USED FOR INTERCONNECTION ' UTILITY CALCULATIONS GRID SUPPLY SIDE TAP (N1 EXISTING 100A BLADE TYPE (N)MA SMART FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE SE3800H-USMN METER 3800 WATT INVERTER JUNCTION BOX PV MODULES 3 o3 o OR EQUIVALENT 9 EXISTING A h TRINA SOLAR:TSM-390DE09C.07 ,� 100A MAIN ate. ( O �. �� ( _� F + // (11)MODULES < �� PANEL M — - / OPTIMIZERS WIRED IN: FACILITY —' '- COY (1)SERIES OF(11)OPTIMIZERS LOADS 20A FUSES i ( —IFS ry SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT a aaouNo D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 s u n r u n 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 S88 MYLES STANDISH BLVD,TAUN7ON,MA 02780.7331 PHONE 0 FAX U CUSTOMER RESIDENCE: MODULE CHARACTERISTICS MARY HAUSER TRINA SOLAR:TSM-390DE09C.07: 390 W S440 OPTIMIZER CHARACTERISTICS: 9 BAKER AVE,YARMOUTH,MA, OPEN CIRCUIT VOLTAGE: 40.8 V MIN INPUT VOLTAGE: 8 VDC 02673 MAX POWER VOLTAGE: 33.8 V MAX INPUT VOLTAGE: 60 VDC SHORT CIRCUIT CURRENT: 13.35 A MAX INPUT ISC: 14.5 ADC TEL.(617)999-0077 MAX OUTPUT CURRENT 15 ADC APN:YARM-000045-000004 PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 223R-009HAUS SYSTEM SIZE: 4290 W SYSTEM OPEN CIRCUIT VOLTAGE: 11 V DESIGNER: (415)580-6920 ex3 SYSTEM OPERATING VOLTAGE: 380 V ODETTE MANIRAMBONA MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 11.29 A SHEET SYSTEM SHORT CIRCUIT CURRENT: 15 A ELECTRICAL REV A 2/8/2023 PAGE PV-4.0 Tampere.srawn-4.0.a7 \A/A RNING INVERTER NOTES AND SPECIFICATIONS: Y Y/1 •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISC 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR __..__ _......__._ _._..... IF REQUESTED BY THE LOCAL AHJ. XIMUM SYSTEM VOLTAGE 480 VD •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. • •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: THE OPEN POSffION METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:690.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B), 705.20(7),706.15(C) WARNING WARNING: PHOTOVOLTAIC POWER SOURCE DUAL POWER SUPPLY LABEL LOCATION: SOURCES:UTILITY GRID INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AND PV SOLAR ELECTRIC AT EACH TURN,ABOVE AND BELOW PENETRATIONS, SYSTEM ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:890.31(D)(2) LABEL LOCATION: UTIUTY SERVICE METER AND MAIN CAUTION : SERVICE PANEL. PER CODE(S):NEC 2023:705.30(C) AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS OVERCURRENT DEVICE j SOLAR PANELS ON ROOF LABEL LOCATION: , LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:890.12(D)(2),IFC • , s u n r u n OCPD(IF APPLICABLE). 2018:1204.5.3 PER CODE(S):NEC 2023:705.12(B)(2) r--i •- -- 4„ _-.• A WARNINGS SOLAR PV SYSTEM EQUIPPED #180120 THIS EQUIPMENT FED BY 888 MVLE8 STANOI.N BLVD,TAUNTON,MA,02780.7331 MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN 0 RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE MIRY HAUSER SHALL NOT EXCEED AMPACITY OF ----MAIN PANEL (I NT) 9 BAKER AVE,YARMOUTH,MA, BUSBAR LABEL LOCATION: 3 TURN RAPID SHUTDOWN 02673 PV LOAD CENTER(IF APPLICABLE)AND SWITCH TO THE"OFF" INVERTER (EXT) SERVICE ENTRANCE TEL.(617)999-0077 ANY PANEL THAT UTILIZES"THE SUM POSITION TO SHUT DOWN OF BREAKERS RULE". PV SYSTEM AND REDUCE FUSED AC DISCONNECT APN:YARM-000045 O00004 PER CODE(S):NEC 2023:705.12(B)(3) SHOCK HAZARD IN THE PROJECT NUMBER: ARRAY. III —PV PRODUCTION METER 223R-009HAUS PV SYSTEM DISCONNECT DESIGNER: (415)580-6920 ex3 MA\IMUM AC OPERA IING CURRENT:16.00 AMPS 9 BAKER AVE, YARMOUTH, MA, 02673 ODETTEMANIRAMBONA NOMINAL OPERATING AC VOLTAGE: 240 VAC LABEL LOCATION: ------ SHEET LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10(2) SIGNAGE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS INTERCONNECTION. ARE CONNECTED. PER CODE(S):NEC 2023:890.54,CEC 2022:690.54 PER CODE(S):NEC 2023:690.12(D) REV A 2/8/2023 PAGE PV-5.0 Temp'eh.. o7 e.0.87