HomeMy WebLinkAboutBLDE-23-005548 a< Commonwealth of Official Use Only Massachusetts Permit No. BLDE-23-005548 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/071 APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date;4/5/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 4 PUMP HOUSE LN Owner or Tenant CONNORS CHARLES V Telephone No. Owner's Address CONNORS PAULA M,4 PUMP HOUSE LN,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a buildingpermit? -"'Ap '*�"'' . Yes 0 No 0 (CheckAppro ri to ox Purpose of Building Utility Authorization No. I s 7 8J Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 rtr -01.Mbhirs Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (23 Panels 8.97 KW DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool g hovend. ❑ g rnd. ❑ No.of Emergency Lighting r Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Ton Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Water No.of Devices or Equivalent Heaters KW No.of No.of Ballasts Data Wiring: Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE ❑ BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties ofperjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Alt.Tel.No.: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. 'PERMIT FEE:$150.00 64-&ei -S7 Z.3(:2 te ., CRIPti cP t.t& { Please email permit to eastmapermits@sunrun.com *_ Commonwealth ol///a achu6etfa Official Use Only /� 3'55�6 —�0=�t c� Permit No. �Z— _1111= �LJepartment o/.iro Sarvicai ' 111 Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 04/03/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)4 Pump House Ln Owner or Tenant Paula Connors Telephone No. (508) 815-9781 Owner's Address 4 Pump House Ln Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes ❑ No ❑ (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service 200 Amps J,0/ .A/(Volts Overhead ❑/ Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd g ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar. 23 solar panels at 8.97 KwDC. NO ESS. Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners IFIRE ALARMS INo.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices Tot No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump I Number I Tons I KW No.of Self-Contained Totals: r Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Municipal Local❑ Connection El Other No.of Dryers Heating Appliances KW Security Systems:* No.of WaterNo.of Devices or Equivalent K� No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: S /�J D ��? VE / jb, �/ Attach additional detail if desired, or as required by the Inspector of Wires Estimated Value of Electrical Work: $11805 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND El OTHER ❑ (Specify:) 1 certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al itidit., Licensee: Nathan Ashe Signature LIC.NO.:21136 A (If applicable,enter "exempt"in the license number line.) Address: 695 Myles Standish Blvd. Taunton, MA 02780 Bus.Tel.No.•978 594-3519 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Alt Lic.No.Tel.No.: 978 7s3 7881 OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $ I Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE A DESCRIPTION r •SYSTEM SIZE:8970W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(23)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET ara •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE6000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ACAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. n DC DISCONNECT(S) •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). ABBREVIATIONS I- 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L_I SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT s u n r u n AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION ATTIC VENT DC DIRECT CURRENT FLUSH ATTIC VENT #180120 (E) EXISTING PVC PIPE VENT VICINITY MAP BPS MVLAA STANOISH BLVD,TAUNTON.MA,St7B0.7W PHONED ESS ENERGY STORAGE SYSTEM FAXB METAL PIPE VENT EXT EXTERIOR CUSTOMER RESIDENCE: INT INTERIOR T-VENT PAULA CONNORS MSP MAIN SERVICE PANEL SATELLITE DISH 4 PUMP HOUSE LN,YARMOUTH, MA,02673 IN) NEW NTS NOT TO SCALE . FIRE SETBACKS • TEL.(508)815-9781 OC ON CENTER • APN:YARM-000047-000068 PREFAB PREFABRICATED HARDSCAPE PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT 223R-004CONN PV PHOTOVOLTAIC —PL— PROPERTY LINE MS)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE A•N ��„ DESIGNER: SOLAR MODULES i 7 RAISSA BWIZA TL TRANSFORMERLESS 1 SCALE:NTS s =.. { .. a ' .__._._ ' �. .' SHEET TIP TYPICAL • • REV NAME DATE COMMENTS COVER SHEET ✓ VOLTS W WATTS ¢; .0 + "s•.. REV:A 4/1/2023 LAN LANDSCAPE k SNR MOUNT - SNR MOUNT&SKIRT PAGE PV-1.0 POR PORTRAIT T•mpd._w A 1.0.87 L E 2-3 -- cc:-.) `'ce SITE PLAN-SCALE=1/16"=1'-0" SITE PLAN DETAIL-SCALE=3/64"=1'0" tN (E)SKYLIGHT P (E)RESIDENCE TYP 4 (N)ARRAY AR-04 ,. ---Ni i i e, •., t 1—P C 0 Y .„..---"......-----....: .\ \ (E)VERANDA ,—(N)ARRAY AR-03 -( : ' ' \-\\.:_ ,:'' : ____ :___:.--- , \ . (N)ARRAY AR-02 * A (N)ARRAY AR-01 '} \ / , / 1ACI PM INV \ '. ''s:: sunrun / , ,,/ , ., ..„, \ Tso 6 \ v, SE .\ , — OG. #180120 o" BBS MYLES STANDISH BLVD,TAUNTON.MA,02700-7331 /\\ \ PHONE e�- \......(E)GATE/ A B FENCE CUSTOMER RESIDENCE: PAULA CONNORS 4 PUMP HOUSE LN,YARMOUTH, MA,02673 - (E)DRIVEWAY TEL.(508)815-9781 APN:VARM-000047-000068 PROJECT NUMBER: 223R-004CONN DESIGNER: (415)58043920 ex3 ARRAY TRUE MAG PV AREA RAISSA BWIZA PITCH AZIM AZIM (SQFT) SHEET AR-01 45° 247° 261' 124.2 SITE PLAN AR-02 45' 247' 261° 206.9 REV:A 4/1/2023 AR-03 19° 67' 81' 103.5 . PAGE PV-2.0 AR-04 45° 247' 261° 41.4 TmplaM1 MMnlon_4.0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 14'-0" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 7'-5" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE '- " 2'-1" 4'-0" 2'-0" STAGGERED 5/16"X 4.5":2.5"MIN. DETAIL SNR-DC-00436 EMBEDMENT AR-03 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 13'-0" 16" RL UNIVERSAL,SPEEDSEAL ON COMP,SEE 5'-4" 2'-1" 4'-0" 1'-9" STAGGERED DETAIL SNR-DC-00436 AR-04 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 7'-6" 16" RL UNIVERSAL SPEEDSEAL TRACK ON COMP,SEE 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED DETAIL SNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" - 2'-7" D2-AR-02-SCALE:1/8"=1-0" AZIM:247° 2'_5" , 2-4" AZIM:247° PITCH:45° 11,_7„_. f PITCH:45° 17'-5"_____. ___ __5-2„ _y 1'-1" e_i+_t_,_ i STRUCT, ,I.__ P • 10.-11" ONL • CI n5,�„.1-YP• , �,�Fya3H a ,1rt4,4F � b .. i 4; VINCENT .^, 14'-7' T-5" c MWUMVANEZA N I —. o a 0 CIVIL '5'-4"TYP _ 8'-10" 0 0. _d Signed:04/02/2023 sunrun D3-AR-03-SCALE:1/8"=1'-0" D4-AR-04-SCALE:1/8"=1'-0" AZIM:67° AZIM:247° 0180120 PITCH:19° PITCH:19° MS MYLES STA..KM,TAUNTON.Mn WSW., PHONED FA%o 1,-6" - -- -11'-1" { CUSTOMER RESIDENCE: 1,�„ PAULA CONNORS 1'-6" n n 4 PUMP HOUSE LN,YARMOUTH, INSTALLERS SHALL NOTIFY ENGINEER OF ANY MA,02673 POTENTIAL STRUCTURAL ISSUES OBSERVED t. ti 7,-0„ PRIOR TO PROCEEDING W/INSTALLATION. TEL.(SOIL)815-9781 APN:YARM-000047-000068 10-11 *IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" 5'-4"TYP o o PROJECT NUMBER: n ,, i BOUNDARY REGION OF ANY ROOF PLANE 223R-004CONN EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND DESIGNER: (415)580-6920 ex3 8'-3" OVERHANG REDUCED WITHIN THE 12" RAISSA BWIZA 2'-4" BOUNDARY REGION ONLY AS FOLLOWS: **ALLOWABLE ATTACHMENT SPACING SHEET , 11.-7"-- 5'-3" INDICATED ON PLANS TO BE REDUCED BY 50%. LAYOUT **ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE REV:A 4/1/2023 ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 Template—wrson_4.0.87 r TAP DEVICE MUST BE MARKED"SUITABLE 120/240 VAC FOR USE ON THE LINE SIDE OF THE SERVICE SINGLE PHASE EQUIPMENT'OR EQUIVALENT SERVICE NOTE:TOTAL PV BACKFEED=31A < OMETER It: USED FOR INTERCONNECTION EVERSOURCE 2258684 CALCULATIONS UTILITY GRID I 1 I SUPPLY SIDE TAP 4 (1 EXISTING 100A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT BLADE TYPE REVENUE SE6000H-USSN 100 A AC DISCONNECT METER 6000 WATT INVERTER JUNCTION BOX PV MODULES MAIN BUS v3', 3 (3) (2) OR EQUIVALENT (I) TRINA SOLAR:TSM-390DE09C.07 • - EXISTING 100A MAIN 11 ./` �n // (23)MODULES < moo. o�a --�� _ .—.� .� . 'w/ OPTIMIZERS WIRED IN: • PANEL �JI `Y (1)SERIES OF(11)OPTIMIZERS FACILITY 35A FUSES - I I ( (1)SERIES OF(12)OPTIMIZERS LOADS - -z= SQUARED SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 BBS MYLES STANDISH SLVD,TAUNTON,MA,02780.7331 PHONED FAX 0 CUSTOMER RESIDENCE: MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: PAULA CONNORS TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC 4 PUMP HOUSE LN,YARMOUTH, OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC MA,02673 MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC TEL.(508)815-9781 APN:YARM-000047-000068 SYSTEM CHARACTERISTICS-INVERTER 1 PROJECT NUMBER: 223R-004CONN SYSTEM SIZE: 8970 W SYSTEM OPEN CIRCUIT VOLTAGE: 12 V SYSTEM OPERATING VOLTAGE: 380 V DESIGNER: (415)580-6920 ex3 MAX ALLOWABLE DC VOLTAGE: 480 V RAISSA BWIZA SYSTEM OPERATING CURRENT: 23.61 A SHEET SYSTEM SHORT CIRCUIT CURRENT: 30 A ELECTRICAL REV:A 4/1/2023 PAGE PV-4.0 ramp n canon e.0.m /WARNING INVERTER I NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53,CEC 2022:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL OF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(8).CEC 2022:690.13(B) AWARNING • DUAL POWER SUPPLY SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC AND PV SOLAR ELECTRIC POWER SOURCE SYSTEM LABEL LOCATION: LABEL LOCATION. INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, CAUTION : UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2020:705.12(C),CEC PER CODE(S):NEC 2020:690.31(D)(2),CEC 2022: 2022.705.12(C) 690.31(D)(2) AWARNING MULTIPLE SOURCES OF POWER RAPID SHUTDOWN SWITCH POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS FOR SOLAR PV SYSTEM --- MAIN PANEL (INT) e,, OVERCURRENT DEVICE — - - - -AC DISCONNECT (INT) LABEL LOCATION: S u n r u n LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN I I ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2020:690.56(C)(2), OCPD OF APPLICABLE). CEC 2022:690.56(C)(2),IFC 2018:1204.5.3 PERCODE(S):NEC2020:705.12(B)(3)(2), -- — SOLAR PANELS ON ROOF CEC 2022:705.12(B)(3)(2) 4" I I ' G SOLAR PV SYSTEM EQUIPPED #180120 THIS EQUIPMENT FED BY 1 695 MVLES STNI019H BLVD,Tg1NTOM.Mg 02750.7331 I MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN 0 RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE PAULA CONNORS SHALL NOT EXCEED AMPACITY OF I 4 PUMP HOUSE LN,YARMOUTH, BUSBAR MA,02673 3" TURN RAPID SHUTDOWN INVERTER (EXT)-, LABEL LOCATION: PV LOAD CENTER OF APPUCABLE)AND SWITCH TO THE"OFF" SOL. P.,OELs TEL(508)815-9781 ANY PANEL THAT UTILIZES'THE SUM POSITION TO SHUT DOWN AC DISCONNECT (EXT)- APN:YARM-000047-000068 OF BREAKERS RULE'. PV SYSTEM AND REDUCE PV PRODUCTION METER J PROJECT NUMBER: PER CODE(S):NEC 2020:705.12 (B)(3)(3),CEC 2022:705.12(3)(3)(3) SHOCK HAZARD IN THE 223R-004CONN ARRAY. 111 SERVICE ENTRANCE— 11 PV SYSTEM DISCONNECT DESIGNER: (415)580-6920 ex3 MAXIMUM AC OPERATING CURRENT:25_00AMPS 4 PUMP HOUSE LN, YARMOUTH, MA, 02673 RAISSABWIZA NOMINAL OPERATING AC VOLTAGE: 240 VAC SHEET LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10,CEC 2022:705.10,710.10 SIG NAG E LABEL LOCATION: ON ORR NO MORE THAT 1 M(3 FT)FROM THE SERVICE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS INTERCONNECTION. ARE CONNECTED. REV:A 4/1/2023 PER CODE(S):NEC 2020:690.54,CEC 2022:690.54 PER CODE(S):NEC 2020:690.56(C),CEC 2022:690.56(C) PAGE PV-5.0 Temylafe_ve n_4.087