Loading...
HomeMy WebLinkAboutBLDE-23-005747 Commonwealth of Official Use Only �E . Massachusetts Permit No. BLDE23-005747 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/14/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 23 SWIFT BROOK RD Owner or Tenant DE OLIVEIRA ROBERO A Telephone No. Owner's Address 23 SWIFT BROOK RD, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(16 Panels 6.24 KW DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Tonal No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertinc Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Eouivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 a V ( ( ( (C-- - 64-Ks. P a:») Please email permit to eastmapermits@sunrun.com Commonwealth o`r/Iaddachudelld Official Use Only ►�--1 =ft e[.� c7 Permit No. ,f. 2-,—S 7 g-t7 e -'0 eparimeni o�,}ire Serviced Occupancy and Fee Checked — BOARD BOARD OF FIRE PREVENTION REGULATIONS •� [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 04/12/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)23 Swift Brook Rd Owner or Tenant Roberto Deoliveira Telephone No. (508) 367-0254 Owner's Address 23 Swift Brook Rd Yarmouth MA 02664 Is this permit in conjunction with a building permit? Yes V No n (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps / Volts Overhead ® 1 Undgrd ElNo.of Meters 1 -NevI CI Service Amps / Volts Overhead n Undgrd n No.of Meters I w M iLIN ber of Feeders and Ampacity f CV !� �o\t aL ation and Nature of Proposed Electrical Work: 1 "'''"" I stallation of a rooftop mounted photovoltaic solar consisting of 16 solar panels producing 6.24 KW DC with No ESS Cr)c� Lu U i i Completion of the following table may be waived by the Inspector of Wires. 0 1 t� z_N N .of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total r ,i,j 'Q pTransformers KVA i n 71 .of Luminaire Outlets No.of Hot Tubs Generators KVA „,m,_,, rTM r--- NQ.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS [No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump I Number Tons I KW No.of Self-Contained - Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal Connection ❑ Other No.of Dryers Heating Appliances KW Security Systems:* No.of Water No.of No.of Devices or Equivalent Heaters KW No.of Data Wiring: Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: $8212 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136 A (If applicable,enter "exempt"in the license number line.) 978 594-3519 Address: 695 Myles Standish Blvd. Taunton. MA 02780 Bus.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Alt.Licl No. 978 793-7881 OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)El owner ❑owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $ I Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION II •SYSTEM SIZE:6240W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(16)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET ILWA •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE6000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). OAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. ED DC DISCONNECT(S) •12.14 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •18.97 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). ABBREVIATIONS I—1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY S Iu AZIM AZIMUTH COW COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (E) EXISTING - FLUSH ATTIC VENT VICINITY MAP HIS MYLES STANDISH BLVD.TAUNTON.MA,027130.7331 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT RHONE0 4P LotPAX EXT EXTERIOR .. METAL PIPE VENT Pot CUSTOMER RESIDENCE: INr INTERIOR MSP AwwsERVICEPANEL T-VENT 23 Swift Brook Rd, 230SWIFTO BROOK RD,A (N) NEW South Yarmouth,MA YARMOUTH,MA,02664 SATELLITE DISH 02664,United States NTS NOT TO SCALE TEL.(508)367-0254 OC ON CENTER • FIRE SETBACKS APN:YARM-000067-000275 d PRE-FAB PRE-FABRICATED i Q PROJECT NUMBER: PSF POUNDS PER BOUARE FOOT HARDSCAPE �Ca, 223R-023DEOL PV PHOTOVOLTAIC ,� DESIGNER: (415)580-6920 ex3 RED RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE Qa ENOCK KWIZERA TL TRANSFORMERLESS SOLAR MODULES m'� 28' SCALE:NTS SHEET TVP TYPICAL " ° 3. REV NAME DATE COMMENTS V VOLTS s C.Stop&Shop- - COVER SHEET H REV:A 4/12/2023 W WATTS I S1van Pond _ -'. -. - LAN LANDSCAPE SNR MOUNT BASS RIVER Jul -- PAGE POR PORTRAIT ' SNR MOUNT&SKIRT Q WIr PV-1.0 T.WA.b_wlscn_4..0.87 7 a \. SITE PLAN-SCALE=1/16"=1'-0" '' SWIFT BROOK RD.. PL PL Pt - PL -------------------- \-----"-------- , , rMP SE 0 PM INV • • (E)GATE (E)RESIDENCE-- (N)ARRAY AR-01 -- _ - - sunrun (E)FENCE---""' --- (E)DETACHED STRUCTURE \ ' i #180120 805 NVLES STANDISH BLVD TAUMIXJ NA.ONE,', PHONE 0 FAX 0 CUSTOMER RESIDENCE: ROBERTO DEOLIVEIRA 23 SWIFT BROOK RD, Pt YARMOUTH,MA,02664 - TEL.(508)367-0254 \________ Ft q, ARRAY TRUE MAG PV AREA APN:YARM-000067-000275 - PITCH AZIM AZIM (SOFT) PROJECT NUMBER: AR-01 26° 170' 184° 331.1 223R-023DEOL DESIGNER: (415)580-6920 ex3 ENOCK KWIZERA SHEET SITE PLAN REV:A 4/12/2023 PAGE PV-2.0 Tempah_verson 1.0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Max OC Max Landscape Max Landscape Max Portrait Max Portrait Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration AR-01 COMP SHINGLE-RLU 1-Story 2X4 PRE-FABRICATED TRUSSES 6'-0" 24" RL UNIVERSAL,SPEE SEAL TRACK ON 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED COMP,SEE DETAIL SNR-DC-00436 D1-AR-01-SCALE:3/16"=1'-0" AZIM:170° PITCH:26° STRICT ONL r,0.1tH OF'H4,g� C 19 VINCENT yam o MWUMVANEZA y CIVIL N�. 2 9 ,..�EAEO �44- c°l ONALEN��� S ig ned:04/12/2023 52'4" 4' 3'-10" 1'-11" +--- — LI ii I ii L .. I l Li L it 0 T-3�� sunrun . . , 6'TYP f #180120 WILES sr,was"BLvo,rauuroN MA,onm.rv+ CUSTOMER RESIDENCE: ROBERTO DEOLIVEIRA 23 SWIFT BROOK RD, YARMOUTH,MA,02664 TEL.(506)367-0254 APN:YARM-000067-000275 PROJECT NUMBER: SEE SITE PLAN FOR NORTH ARROW 223R-023DEOL DESIGN CRITERIA STRUCTURAL NOTES °IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION DESIGNER: (415)560 6920 ex3 MAX DISTRIBUTEDLOAD:3 PSF INSTALLERS SHALL NOTIFY ENGINEER OF ANY OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS),THEN ENOCK KWIZERA SNOW LOAD:30 PSF POTENTIAL STRUCTURAL ISSUES OBSERVED ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED SHEET WITHIN THE 12"BOUNDARY REGION ONLY AS FOLLOWS: WIND SPEED: PRIOR TO PROCEEDING W/INSTALLATION. °°ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO LAYOUT 140 MPH 3-SEC GUST. BE REDUCED BY 50%. S.S.LAG SCREW °°ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF REV:A 4/12/2023 5/16":2.5"MIN.EMBEDMENT ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 Templar.vxalan_4.0.D7 120/240 VAC NOTE:TOTAL PV BACKFEED=31.25A SINGLE PHASE USED FOR INTERCONNECTION SERVICE CALCULATIONS METER#: < O EVERSOURCE 2368308 UTILITY GRID I SUPPLY SIDE TAP h- ,::::->® (N)LOCKABLE I EXISTING 100A BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE SE6000H-USSN 1 METER 6000 WATT INVERTER JUNCTION BOX PV MODULES (3) 32 (2) OR EQUIVALENT (i) TRINA SOLAR:TSM-390DEO9C.07 �_:— EXISTING L. d A / (16)MODULES �� PANE MAIN ,,o, i 'J O _-7/-* -�i �— JI *4// OPTIMIZERS WIRED IN: - (1)SERIES OF(8)OPTIMIZERS FACILITY 35A FUSES I I (1)SERIES OF(8)OPTIMIZERS LOADS l= SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 e05 MYLES STANDISH BLVD TAUNTON.MA,02780-7111 PNONE0 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: a a TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE 60 VDC RCUSTOMER RESIDENCE: MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC 23 SWIFT BROOK DEOLIVEIRA ROOK RD, SHORT CIRCUIT CURRENT: 12.14 A MAX OUTPUT CURRENT: 15 ADC YARMOUTH,MA,02664 SYSTEM CHARACTERISTICS-INVERTER 1 TEL.(508)367-0254 SYSTEM SIZE: 6240 W APN:YARM-000067-000275 SYSTEM OPEN CIRCUIT VOLTAGE: 8 V PROJECT NUMBER: SYSTEM OPERATING VOLTAGE 380 V 223R-023DEOL MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 16.42 A DESIGNER: (415)580 8920 ex3 SYSTEM SHORT CIRCUIT CURRENT: 30 A ENOCK KWIZERA SHEET ELECTRICAL REV:A 4/12/2023 PAGE PV-4.0 Tempate ve on_4.0.87 AWARNINGl INVERTER I NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE • PHOTOVOLTAIC DC DISCONNECT 110.21(B).UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690.OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCALAHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT / PER CODE(S):NEC 2023:690.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B), 705.20(7),706.15(C) AWARNING DUAL POWER SUPPLY SOURCES:UTILITY GRID `'VARNING: PHOTOVOLTAIC II AND PV SOLAR ELECTRIC POWER SOURCE - - SYSTEM LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT. UTIUTY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, CAUTION : SERVICE PANEL. ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. PER CODE(S).NEC 2023:705.30(C) PER CODE(S):NEC 2023:690.31(D)(2)lit AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS SOLAR PANELS Z OVERCURRENT DEVICE LABEL LOCATION: ON ROOF `/ LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOVVN ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:890.12(D)(2),IFC u n r u n • OCPD(IF APPLICABLE). 2018:1204.5.3 PER CODE(S):NEC 2023:705.12(6)(2) 4• WARNING SOLAR PV SYSTEM EQUIPPED 1 #180120 THIS EQUIPMENT FED BY aes lAnS STA..eLSO TAUNTON MA 022e0-,n1 MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE ROBERTO DEOLIVEIRA SHALL NOT EXCEED AMPACITY OF 23 SWIFT BROOK RD, BUSBAR YARMOUTH,MA,02664 3. TURN RAPID SHUTDOWNMAIN PANEL (INT) LABEL LOCATION: ti---. PV LOAD CENTER(IF APPUCABLE)AND SWITCH TO THE"OFF" LA vnWsLs TEL.(508)367-0254 ANY PANEL THAT UTILIZES"THE SUM POSITION TO SHUT DOWN APN:VARM-000067-000275 OF BREAKERS RULE". PV SYSTEM AND REDUCE INVERTER (EXT) PER CODE(S):NEC 2023:705.12(B)(3) SHOCK HAZARD IN THE SERVICE ENTRANCE PROJECT NUMBER: -PV PRODUCTION 223R-023DEOL ARRAY. Ell FUSED AC DISCONNECT- PV SYSTEM DISCONNECT METER DESIGNER: (415)580-6920 ex3 MAXIMUM AC OPERATING CURRENT:25_00 AMPS 23 SWIFT BROOK RD, YARMOUTH, MA, 02664 ENOCKKWIZERA NOMINAL OPERATING AC VOLTAGE: 240 VAC SHEET LABELLOCATION. PER CODE(S):NEC 2023:705.10(2) .S I l7 NAG E LABEL LOCATION: ON ORR NO MORE THAT 1 M(3 FT)FROM THE SERVICE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS INTERCONNECTION. ARE CONNECTED. REV:A 4/12/2023 PER CODE(S):NEC 2023:890.54 PER CODE(S):NEC 2023:690.12(D) PAGE PV-5.0 Template wir n_a o n,