Loading...
HomeMy WebLinkAboutEngineer PlanREPLACE EXISTING D-BOX - 1) MATCH INLET & OUTLET INVERTS 2) PROVIDE NEW OUTLET FOR FLOW TO PROPOSED S.A.S. AGNETIC NAIL _. = 100.48 L a 100.0� J 99.89 99.73 r 9957 PK SET x 99.97 D I II L4k, P 4. x 99.76 kU M N& 3=1 OWNER OF RECORD NIKOLAIDIS, ROSEANNA TR NIKOLAIDIS, CHARLAMBROS TR 4 VINEYARD CIRCLE SAGAMORE BEACH, MA 02562 - - 64- - EXISTING CONTOUR x 60.98 EXISTING SPOT GRADE -W EXISTING WATER SVC. -G - EXISTING GAS SERVICE 100.51 121.09 CBSEAL Permit valid f r �A*k-OIQ� WIKVFM t/NI,Y, due to Slatf�d LoTEt-j% ppic variances. 1oC.B1 Board of Healt Ifc%ie�and aptluired for any future dditiolr%, nut on��nI orations to PK SET sewage facilities and/or structEfttWg. 100.48 Yarmouth Health Department 37 APPROVED t601.08 100.28 Zi ^ VP -V 100,79 iv. 100. l�AKNYii 99,64 99;26„" x 99.11 / EXISTING S.A.S. (TO REMAIN) 3-FLOW DIFFUSORS W/4' STONE 100.21x PROPOSED S.A.S. 3-LC6 CHAMBERSS W/4' STONE ti `'% , 99.12 ��• O `�Y �OSO•, _ i p�` O• EXIS7ING PUMP CHAMBER 9971 t 99,24 1000 GALLON CAPACITY x 99 98.90 .91 �9%,05 �it 97.96 9. o x 2 0 97 ra x 97.31 EXISTINGx 97.30 HOUSE(#36 T.O.F. =99.6.E ft --� v Date en By Best y ••""" stern @ Cape Point Cape Cod Inflatable Park a lass) a�porariy rao�- �Big &Tall of Vermouth cwm�aatae Massachusetts Route28 0 Kelly Roofing a J Main Sl t Painting 9 vLuke s Super Liquors ® Takis Pita SpiceGamer35 wM score r N it - S U IF • Q a Pisanos Pro Q _ Property Services Cill Dora Concrete A Creations ° LOCUS MAP GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: 310 CMR 15.405(h)-CONTENTS OF LOCAL UPGRADE APPROVAL EXISTING SEPTIC TANK 1) A 1' reduction to the required 5' separation between maximum 1500 GALLON CAPACITY seasonal high groundwater elevation and bottom of S.A.S., for x 96.76 98.75{`� � x 96.05 X7.86 S 86 96.08 / / �� 95.89 SJ, tss� x 9828 Op, 20a / x 95.48 95.48 x x 96.35 � / x 97.35 x 95.20 //LOT}sF 7i96.00 9k' S x 96.02/ 94.95 OF XSAS `�6'' �• o PETER T. AOe McENTEE F CIVIL 95.24 No. 35109 4' of minimum separation. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. S. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC RECTEM COMPONENTS NOT SHOWN ON THE PLAN. . IWINSPECTION PERFORMED BY TOWN INICATED NUMBER OF ACTUAL BEDROOMS EXCEED DESIGN FLOW ON FILE OF SEPTIC SYSTEM. MAY 25 F 6 2023 MAP ID: 31-142 M qZ N ° J/� CL T W 7 Q 0 A� Q 3 vi V) W O �j0 U) w U V Z !n Wig_- � a W Nw o U Ld Z C W O jv U a 1..1. o V / w /0�/ C a_ M N 6 N z Z I 0 o N r- ZY 3 ~ U o = a U � M ro a t7 0 to = a<C I mr to m r<noi t'n IV _(°n NOTE: TO PREVENT BREAKOUT, THE PROPOSED - - PLAN view FINISH GRADE SHALL NOT BE < EL: 98.0 z co PROPOSED D-BOXES FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. zz• 4 4 4 �2 4 4 Q a - N o PROVIDE ACCESS TO D-BOX COVERS INSTALL RISER & COVER OVER ONE CHAMBER(MIN.) t Q z WITHIN 6" OF FINISH OF GRADE AND SET TO WITHIN 3" OF FINISH GRADE TO SERVE L4 W o AS AN INSPECTION MANHOLE. `', 4 4 w F.G. EL.=101.3t F.G. F.G. EL.=98.9t f EL.=99.3f F.G. EL.=99.3f s r 1 .." n `" T �- W W MR L = 16' L = 16' c Q S=1% (MIN.) Q S=1% (MIN.) CROSS SECTION S ` N 0L 4"SCH40 PVC 2" scH 40 4"SCH40 PVC - 2" LAYER OF 1 /8" SPE��` ,•�, sacnvicnnorvs m o ®O ® TO 1/2 DOUBLE ° • _° •. ° • s r�° u� E `n K' FORCE MAIN s• e" 12" WASHED STONE ""° "" �° CONNECTION (OR APPROVED FILTER FABRIC) - U INV.=9.5t INV.=98.28 EXISTING PROPOSED EXISTING & PROPOSED INV.=97.79 3.5' 3' 3.5' 3/4 -1 1 /2 DB-5 (H20) DB-3 (H20) W i- PUMP D-BOX 1 PROPOSED D-BOX 2 INV.=98.45 EFFECTIVE WIDTH = 10' DOUBLE WASHED U � TO REPLACE EXISTING & USE WIGGIN INV.-97.50 - STONE � EXISTING PUMP CHAMBER PROPOSED EXIST. D-BOX INV.=97.96 DB-3H OR USE 3 LC -6 LEACHING CHAMBERS IN SERIES WITH EXISTING HOUSE(#36) (n ' n TO REMAIN USE WIGGIN EQUAL DB-5H OR 3.5' OF DOUBLE WASHED STONE ON ALL SIDES W Z v� EQUAL H-10 RATED Q -° U NOTES: TOP CONC. ELEV.=98.33 - BREAKOUT 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.=97.50 ® ® ® O E3 Ea E3 ELEV.=98.00 INVERTS, PRIOR TO INSTALLATION. E3 E3 E3 E3® E3 E3 2) D-BOX SHALL BE SET LEVEL AND TRUE TO BOTTOM ELEV.=96.50 IEE:m S� CSC si. cs. �8 �Q.. W V) O T_ (fl a U `: �-- GRADE ON A MECHANICALLY COMPACTED SIX 3.5' 3 x 6' = 18' 3.5' O �Mo INCH CRUSHED STONE BASE, AS SPECIFIED IN 4' OF NATURALLY OCCURRING i� EFFECTIVE LENGTH = 25' ��N 'S 310 CMR 15.221(2). PERVIOUS MATERIAL �, N 0 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 5' (MIN.) ABOVE G.W. �•' C 4 ) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL ADJUSTED GW, EL=92.0 LEACHING SYSTEM SECTION - _ ���� SEPTIC SYSTEM PROFILE S.A.S. LAYOUT�2s�•� !�' z N ? o w o � N N DESIGN CRITERIA SOIL LOG Z :� y NUMBER OF BEDROOMS: 5 BEDROOMS (SEE NOTE 15, SHEET 1) TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DATE: APRIL 6, 2023 SOIL EVALUATOR: PETER McENTEE SE#1542 --------- 4" KNOCKOUT , 20" DIA. COVER qw c 0 Li U WITNESS: PHIL RENAUD R.S. HEALTH AGENT N DAILY FLOW: 550 GPD TP- - M DESIGN FLOW: 550 GPO ELEV. DEPTH 4" KNOCKOUT 4" KNOCKOUT w w W o GARBAGE GRINDER: NO -AND NOT PERMITTED WITH THIS DESIGN 100.4 q 0 v Z a Lo o LOAMY SAND 4" KNOCKOUT 't LEACHING AREA REQUIRED: (550 GPD) = 743.2 SF 10YR 4/2 -___ _ _ a .74 GPD/SF 99.9 B 6 r. " CO o EXISTING SEPTIC TANKS: 1500 & 1000 GALLON CAPACITIES, IN SERIES LOAMY SAND 72 a PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS, H-20 RATED tOYR 5/8 PERC a 18"/3 PLAN VIEW EXISTING SEPTIC SYSTEM: 3 FLOW DIFFUSERS E/4' STONE S.A.S. EFFECTIVE DIMENSIONS: 12 x 32 x 1' /36" 97.1 C 40" _ r_ _ ®®®� ®®® ®� ® y v ~' SIDEWALL AREA: (12.0' + 32.0') x 2 x 1' = 88.0 SF 22" I BOTTOM AREA: 12.0 x 32.0 = 384.0 SF INVERT ®®®® i° M-C SAND 12" I TOTAL AREA: ........................................................... 472.0 SF 2.5Y 5/4 �� o DESIGN FLOW PROVIDED: 0.74 GPD/SF(472.0 SF) = 349.3 GPD r' 72" r 36" ��. x 92.0 ADJ GW - t01" PROPOSED SEPTIC SYSTEM: 3-LC6 CHAMBERS W/3.5' STONE 90.4 STG GW - 120" SIDE VIEW END VIEW S.A.S. EFFECTIVE DIMENSIONS: 10' x 25' x 1' - cn SIDEWALL AREA: (10.0' + 25.0') x 2 x 1' = 70.0 SF 89.9 12s° WIGGIN LC-6, H-20 LOADING L N o I BOTTOM AREA: 10.0' x 25.0' = 250.0 SF PERC RATE <2 MIN/IN. "B" HORIZON LEACHING CHAMBER ( 0 TOTAL AREA: ........................................................... 320.0 SF STANDING GW 120" � - N - DESIGN FLOW PROVIDED: 0.74 GPD/SF(320.0 SF) = 236.8 GPD INDEX WELL MIW-29 WATER LEVEL=7.3' 3 ZONE B ADJUSTMENT=1.6' NTS c N o W W COMBINED S.A.S. CAPACITY: 349.3 GPD + 236.8 GPD = 586.1 GPD �-