Loading...
HomeMy WebLinkAboutBLDE-23-005822 ti Commonwealth of Official Use Only Massachusetts Permit No. BLDE-23-005822 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/20/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 21 HAZELMOOR RD Owner or Tenant MCGOVERN PANTALEON Telephone No. Owner's Address 21 HAZELMOOR RD, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system.(19 Panels 7.125 KW DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total ,Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 .-~ Please email permit to eastmapermits@sunrun.corn Commonuweanh of//laddachudetta Use Only C -- �l .2ep artntent o .}ire�arvicee BOARD OF FIRE PREVENTION REGULATIONS heck"� 1EEtEEEiIJ R0 ank APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 04/18/2023 City or Town of: Yarmouth To thBy this application the undersigned gives notice of his or her intention to performe the electrical work Wires:Inspector of scribed below. Location(Street&Number)21 Hazelmoor Rd Owner or Tenant Mcgovern Pantaleon Owner's Address 21 Hazelmoor Rd Yarmouth MA 02664 Telephone No. (617)291-8756 Is this permit in conjunction with a building permit? Yes ® No Purpose of Building/ rt,+� ❑ (Check Appropriate Box) Utility Authorization No. Existing Service 100 Amps / Volts Overhead Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead ❑ Undgrd❑ No.of Meters® ,_. I mber of Feeders and Ampacity LIJ N i cation and Nature of Proposed Electrical Work: > N i Installation of a interconnected, roof mounted, photovoltaic solar. 19 solar panels at 7.125 KwDC. NO ESS. LU Completion o the ollowin• table ma be waived b the Ins.•ctor o Wires. o I o.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total V Transformers KVA 0 2 I o.of Luminaire Outlets No.of Hot Tubs Generators KVA mo I o.of Luminaires Swimming Pool Above ❑ In- `o.o mergency ig mg rnd. .rnd. Batte Units o.of Receptacle Outlets --------------- - No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and No.of Ranges Initiatin. Devices No.of Air Cond. Total Tons No.of Alerting Devices Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alertin Devices No.of Dishwashers Space/Area Heating KW Local I] unicipal No.of Dryers Connection n_ ❑ Other Heating Appliances KW Security Systems:* -- No.of Devices or E i uivalent No.of Water No.o Heaters KWNo.of Data Wiring: Si ns Ballasts No.of Devices or E'uivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: OTHER: No.of Devices or E i uivalent Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $9376 Work to Start:ASAP (When required by municipal policy.) Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. Licensee: Nathan Ashe LIC.NO.: 4316 Al (If applicable,enter "exempt"in the license number line.) Signature LIC.NO.:21136 A Address: 695 Mvles Standish Blvd. Taunton MA 02780 Bus.Tel.No.:978 594-3519 No Alt TeL .: *Per M.G.L.c. 147,s.57 61 security work requires Department of Public Safety"S"License: Lic.No. 978 793-7881 . OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one ❑owner ❑owner's a•ent. Owner/Agent Signature Telephone No. PERMIT FEE: $ Please email permit to eastmapermits@sunrun.corn SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION r •SYSTEM SIZE:7125W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(19)VIKRAM SOLAR:VSMDHT.60.375.05 MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION PV-1.0 COVER SHEET J - •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE6000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN SP SUB-PANEL PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE WITH NEW 125 AMP MAIN PANEL WITH 100 AMP MAIN GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. BREAKER. . LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM PV PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ACAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. n DC DISCONNECT(S) •11.65 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •18.20 AMPS DEBATED SHORT CIRCUIT CURRENT(690.8(A)8 690.8(B)). •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(6)(2)(2). ABBREVIATIONS r-1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER - CHIMNEY s u n r u n AZIM AZIMUTH ATTIC VENT COMP COMPOSITION FLUSH ATTIC VENT DC DIRECT CURRENT i PVC PIPE VENT #180120 (E) EXISTING VICINITY MAP 4 METAL PIPE VENT 695 MYLES STANDISH BLVD,TAUNTON.MA,6I790.7131 PHONED ESS ENERGY STORAGE SYSTEM FAX 0 EXT EXTERIOR ., T-VENT j E T T 5 CUSTOMER RESIDENCE. INT INTERIOR MCGOVERN PANTALEON MSP MAIN SERVICE PANEL Th SATELLITE DISH t O 21 HAZELMOOR RD, Boston INN NEW YARMOUTH,MA,02664 FIRE SETBACKS ►"yi RIG NOT TO SCALE - TEL.(617)291-8756 o C ON CENTER -' APN:YARM-000078-000209 HARDSCAPE 9V ldence PREFAB PREFABRICATED PSF POUNDS PER SQUARE FOOT -PL- PROPERTY LINE O P223R-0 1 PAN NUMBER: 1 PV PHOTOVOLTAIC CT T7 221 Ha2elrno0r Road 415 580-6920 ez3 (^� /'�('�[ ,M, DESIGNER: ( ) RSD RAPID SHUTDOWN DEVICE _ - SOLAR MODULES R H V V l n TRANSFORMERLESS 1 SCALE:NTS .LAND LARRY ADLAWAN — 9 SHEET TYP TYPICALREV NAME DATE COMMENTS COVER SHEET V VOLTS W WATTS O d REV A 4/18/2023 LAN LANDSCAPE SNR MOUNT _ _ _ POR PORTRAIT SNR MOUNT 8 SKIRT PAGE PV-1.0 VS::::;:a)E„,23 --... ), = sEzz SITE PLAN-SCALE-1/16"•1'-0" • \�J HAZELMOOR VW N Pl L \ Pl - g \---- 73 \ . AMP SE 0 PM INV \. , ' (E)FENCE -... \ (E)GATE------------ S u n r u n (N)ARRAY AR-01-------- (E) #180120 RESIDENCE B. oSSTAND..BLw.TAwroia,IAA.02reo-7n1 rAxo (N)ARRAY AR-02 CUSTOMER RESIDENCE: MCGOVERN PANTALEON ARRAY TRUE MAG PV AREA 21 HAZELMOOR RD, PITCH AZIM AZIM (SOFT) YARMOUTH,MA,02664 AR-01 34° 260° 274• 119.8 TEL.(817)291-8756 AR-02 23' 170' 184° 259.5 APN:VARM-000078-000209 -----i - Pi. PROJECT NUMBER: -� PL 223R-021PANT PL DESIGNER: (415)580-6920 ex3 (E)DETACHED LARRY ADLAWAN STRUCTURE p1 SHEET SITE PLAN REV:A 4/18/2023 PAGE PV_2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION I Max OC Max Landscape Max Landscape Max Portrait Max Portrait Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration RL UNIVERSAL,SPEEDSEAL TRACK ON AR-01 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 7'-5" 20" COMP,SEE DETAIL SNR-DC-00436 2'-0" 3'-4" 1'-8" STAGGERED AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 12'-8" 20" RL UNIVERSAL,SPEEDSEAL TRACK ON -0" 3-4" COMP,SEE DETAIL SNR-DC-00436 1' 8" STAGGERED D1-AR-01-SCALE:3/16"=1'-0" AZIM:260' 6 -6"---'—— 17'-6" PITCH:34° "- STRUCT ONL �000,m44,r eM: NZA ) . 2 MOM • _ a _ 10/109 <,`,. 1 .zjr •0NA1.0., Sig ned:04/18/2023 D2-AR-02-SCALE:3/16"=1'-0" } 4'-9" 17'-0„ 18'-6" AZIM:170° PITCH:23° V-10„ 0 0 ❑ 0 ❑ o-__ sunrun -,--5'TYP--I ❑ ❑ ❑ in ❑ 0 ❑ ❑ 6'-11" 1(r-6" 8180120 005 MVLBS STANDISH BLVD,TAUNTON MA 02700-].1 FAX 0 CUSTOMER RESIDENCE: MCGOVERN PANTALEON O o (1 n n 6 1 21 HAZELMOOR RD, 2'I YARMOUTH,MA,02664 -7" TEL.(617)291-8756 APN:YARM-000076-000209 SEE SITE PLAN FOR NORTH ARROW PROJECT NUMBER. 9" • 5'-10"----I-2'-8"- 5'-10"------.,..-- ------- -----------21'-9„—____.._.. 223R-021PANT -DESIGNER: (415)580-8920 ex3 DESIGN CRITERIA STRUCTURAL NOTES LARRY ADLAWAN MAX DISTRIBUTED LOAD:3 PSF INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE SNOW LOAD:30 PSF ISSUES OBSERVED PRIOR TO PROCEEDING W/INSTALLATION. EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG SHEET WIND SPEED: REDUCED WITHIN THE 12"BOUNDARY REGION ONLY AS FOLLOWS: LAYOUT 140 MPH 3-SEC GUST. **ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. S.S.LAG SCREW •°ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT REV:A 4/18/2023 5/16" 2.5"MIN.EMBEDMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 Templafe_v° on 10.87 120/240 VAC SINGLE PHASE SERVICE METER#: < O EVERSOURCE 2376237 UTILITY GRID SUPPLY SIDE TAP >{4) ( (N I NEW 100A MAIN BLADE TYPE (N)MA SMART BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: t DISCONNECT REVENUE SE6000H-USSN I METER 6000 WATT INVERTER JUNCTION BOX PV MODULES n OR EQUIVALENT 9 i� NEW 125A / VIKRAM SOLAR:VSMDHT.60.375.05 MAIN PANEL o,®, O 'rs .-� // (19)MODULES < �- I — + / OPTIMIZERS WIRED IN: FACILITY (1)SERIES OF(10)OPTIMIZERS LOADS I AGUTY 35A FUSES 1 1 (1)SERIES OF(9)OPTIMIZERS #rewuo SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT NOTE:TOTAL PV BACKFEED=31.25A 0222NRB 100A CONTINUOUS W L WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS USED FOR INTERCONNECTION 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 CALCULATIONS 120/24OVAC CONNECTS TO TOP LUGS- CALCULATIONS (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 *180120 8a5 MYLES STANDISH BLVD.TAUINTON.MA.02780.7331 PHONE 0 FAX 0 CUSTOMER RESIDENCE: MODULE CHARACTERISTICS MCGOVERN PANTALEON S440OPTIMIZER CHARACTERISTICS: 21 HAZELMOOR RD, VIKRAM SOLAR:VSMDHT.60.375.05: 375 W MINNINPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 41.1 V MAX INPUT VOLTAGE 60 VDC YARMOUTH,MA,02664 MAX POWER VOLTAGE: 34.9 V MAX INPUT ISC: 14.5 ADC SHORT CIRCUIT CURRENT 11.65 A MAX OUTPUT CURRENT: 15 ADC TEL.(617)291-8756 APN:YARM-000078-000209 PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 7125 W 223R-021PANT SYSTEM OPEN CIRCUIT VOLTAGE: 10 V DESIGNER: (415)580-6920 0x3 SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V LARRY ADLAWAN SYSTEM OPERATING CURRENT: 18.75 A SHEET SYSTEM SHORT CIRCUIT CURRENT: 30 A ELECTRICAL REV:A 4/18/2023 PAGE PV-4.0 Tempan ve on_A0.87 WARNING INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:890.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B), 765.20m,706.15(C) WARNING: PHOTOVOLTAIC AWARNING l POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. ' AND PV SOLAR ELECTRIC PER CODE(S):NEC 2023:690.31(D))2) _... - LSYSTEM LABEL LOCATION: _ N . UTILITY SERVICE METER AND MAIN SEEL. PER CODE CCE ODE(S):NEC 2023:705.30(C) VAPID SHUTDOWN SWIT AWARNING FOR SOLARPVSYSTE MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN DO NOT RELOCATE THIS SWITCH PER CODE(S):NEC 2023:690.12(D)(2),IFC OVERCURRENT DEVICE 2018:1204.5.3 LABEL LOCATION: `� OCPD(I BREAKER AND ESS s u n r u n OCPD(IF APPUCABLE). PER CODE(S):NEC 2023:705.12(B)(2) 4 SOLAR h AWARNING SOLAR PV SYSTEM EQUIPPED ON OOF PANELS #180120 THIS EQUIPMENT FED BY Eo srAHa w n sH a� ,r•uHrou,MA, MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN Fes. RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE MCGOVERN PANTALEON SHALL NOT EXCEED AMPACITY OF 21 HAZELMOOR RD, BUSBAR AaLYARMOUTH,MA,02664 LABEL LOCATION: 'I TURN RAPID SHUTDOWN _ PV LOAD CENTER(IF APPUCABLE)AND SWITCH TO THE"OFF' '11 1 TEL.(617)291-8756 ANY PANEL THAT UTILIZES"THE SUM POSITION TO SHUT DOWN APN:YARM-000078-000209 OF BREAKERS RULE'. PV SYSTEM AND REDUCE INVERTER (EXTd PROJECT NUMBER: PER CODE(S):NEC 2023:705.12(B)(3) SHOCK HAZARD IN THE MAIN PANEL (INT. NN PV SYSTEM DISCONNECT .°^n ARRAY. ral ) PV PRODUCTIO MAXIMUM AC OPERATING CURRENT:25.00 AMPS SERVICE ENTRANCE J FUSED AC DISCONNECT DESIGNER: (415)560-0920 ex3 NOMINAL OPERATING AC VOLTAGE: 240 VAC 1 21 HAZELMOOR RD. YARMOUTH, MA, 02664 LARRYADLAWAN LABEL LOCATION: {._... LABEL SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF RLOCMORE PER CODE(S):NEC 2023:705.10(2) SIG NAG E INTERCONNECTION. ON OR NO MORE THAT 1 M(3 HIH FROM THE SERVICE STEMS DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):NEC 2023:690.54 ARE CONNECTED. REV'.A 4/18/2023 PER CODE(S):NEC 2023:690.12(D) PAGE PV-5.0 T.my r.w,io._ao.ri