Loading...
HomeMy WebLinkAboutBLD-22-005603 HERS DDE1Z Massachusetts Home Energy Scorecard Home Energy Use Macsaelmuns I)cpas r • • Encrw.we•.our,•, This scorecard compares the home's energy use and carbon footprint to an average home in Massachusetts. West Great Western Rd - kLZ1 g5G2 Home Energy Use Home Carbon Footprint 66 West Great Western Rd West Great Western road 44 This shows the estimated total energy use(electricity This shows the estimated annual carbon emissions and heating fuel)of your home for one year. The lower associated with your home and is based on your home's the energy use, the better. estimated total annual energy use. The lower the score, Year Built Sq. Footage the less carbon pollution is released into the atmosphere. 2023 1,689 ft' Number of Bedrooms Primary Heating Fuel mmBtu/yr ton/yr 3 Natural Gas Worse Worse Assessment Date Energy Specialist June 8,2023 Paul Graney 300 25 Yearly Energy Use Natural Gas Electric 519 Therms 4,277 kWh 9.7 Yearly Energy Costs* Avg. home $2,560 in MA 125.0 3.7 0 Lights &Appliances Avg. home Better in MA Heating 66 HERS® Index 55 Hot Water RESNET's HERS®Index assesses the energy III Cooling efficiency of a home. A HERS-100 home is as energy 0 efficient as a home built to 2006 code.A HERS-0 home uses zero net energy in a typical year. Learn Electric: $0.31/kWh, Natural Gas: 52.37/Thernn Better more at hersindex.com *These are estimated costs.Actual energy costs may vary and are based on many factors such as occupant behavior, weather and utility rates. Please see the next page for more information on how the Home Energy Use and Home Carbon Footprint are calculated. • 66 West Great Western Rd,Yarmouth, MA 02664 June 8, 2023 I 3.2.3.3174 I RESNET Registry ID: 598477845 Brought to you by 1 ekotrope DDER More Information Ma{SacI.u.cttr. )cpartnu n u7 Encrgy 14suurrc% Your Massachusetts Home Energy Scorecard What is HERS? The Massachusetts Home Energy Scorecard (MA Scorecard) is a tool to assess a The Home Energy Rating System (HERS) Index is the industry standard by which a home's expected energy use, cost, and carbon footprint.A low energy use generally home's energy efficiency is measured and compared with other homes. The lower the means that a home has a smaller carbon footprint and lower energy costs.The MA score,the more energy efficient the home. Scorecard also allows for comparisons of one home's energy use and carbon footprint. This is because the energy use and carbon footprint are calculated without the influence An energy rating has been completed for this home by a certified HERS Rater who did of occupant behavior,which can vary. multiple, rigorous inspections and performance tests.They collected hundreds of data points and input them into Ekotrope RATER software, which performs a year-long Home Energy Use hourly energy simulation to estimate how much energy the home will consume.The The Home Energy Use (HEU)calculation is based on a home's size, design, insulation HERS rater is not affiliated with the builder and their work is reviewed by a third party. levels, air leakage, heating and cooling systems, major appliances, lighting, hot water heating, and any electricity produced by on-site solar PV.The HEU number is "normalized"in the sense that occupant behavior, which can vary, is taken out of the calculation.A home's actual energy use will vary with number of occupants, occupant behavior, weather, and changes to the home. Home Feature Summary Useful Terminology Home Type: Single family detached Btu Model: N/A A Btu, or British Thermal Unit, is a measurement of the heat/energy content of fuel. Community: N/A mmBtu stands for one million Btus. One Btu=the energy produced by a single wooden Conditioned Floor Area: 1,689 ft2 match. One million Btus=the energy produced by 7 gallons of gasoline used in a typical Number of Bedrooms: 3 car. Primary Heating System: Furnace •Natural Gas •95 AFUE Primary Cooling System: Air Conditioner•Electric•16 SEER Carbon Footprint • The greenhouse gas emissions associated with a home's energy use impact the Primary Water Heating: Residential Water Heater•Natural Gas environment.The Carbon Footprint calculation is based on the carbon emissions for the 0.97 UEF annual amounts, types, and sources of fuels used in your home. Measurement is in tons House Tightness: 798 CFM50(2.19 ACH50) of carbon dioxide per year(tons/year). One ton =2,000 miles driven by one car(typical Ventilation: 56 CFM •8 Watts• Exhaust Only 21 mpg car.). For electricity, carbon emissions are based on electricity consumed onsite Duct Leakage to Outside: 57 CFM @ 25Pa(3.37/100 ft2) and the mix of fuel sources used in the region to generate that electricity at the time of Above Grade Walls: R-21 this report. For fossil fuel used in heating and hot water, carbon emissions are based on Ceiling: Vaulted Roof,R-35 the therms of natural gas or gallons of oil or propane used in the home. Window Type: U-Value:0.3,SHGC: 0.25 Foundation Walls: N/A Average Home in Your Area Framed Floor: R-30 The "Average Home in Your Area"refers to the average energy use or carbon footprint of all the homes in Massachusetts before implementation of any energy improvements. The average may vary slightly over time as homes become more efficient due to improvements. 66 West Great Western Rd, Yarmouth, MA 02664 June 8, 2023 I 3.2.3.3174 I RESNET Registry ID: 598477845 Brought to you byekotrope Home Energy Rating Certificate Rating Date: 2023-06-08 Final Report Registry ID: 598477845 Ekotrope ID: kLZ1q5G2 HERS® Index core: ' nnual Savings 66 West Great Western Rd Your home's HERS score is a relative performance score.The lower the $ 2, Yarmouth, MA 02664 number, the more energy efficient the 725 Builder: home.To learn more, visit *Relative to an average U.S.home Starbuck Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 41.4 $1,035 2018 International Energy Conservation Code Cooling 0.4 $32 2015 International Energy Conservation Code Hot Water 8.4 $199 2012 International Energy Conservation Code Lights/Appliances 16.4 $1,294 2009 International Energy Conservation Code Service Charges $0 2006 International Energy Conservation Code Generation(e.g.Solar) 0.0 $0 Total: 66.5 $2,560 HERS Index Home Feature Summary: Rating Completed by: P More Energy Home Type: Single family detached It Model: N/A Community: N/A Energy Rater. Paul Graney 150 RESNET ID: 2649950 Existing Soo Homes ,...:.150 Conditioned Floor Area: 1,689 ft2 Rating Company: Home Energy Raters 120 Number of Bedrooms: 3 180 State Rd,Suite 2U Saga more Beach MA 02562 Reference l00 Primary Heating System: Furnace•Natural Gas•95 AFUE 508 833 3100 Home Primary Cooling System: Air Conditioner•Electric•16 SEER 90 Primary Water Heating: Residential Water Heater••Natural Gas••0.97 UEF Rating Provider: Energy Raters of Massachusetts A0 2 Woodlawn Street Amesbury,MA 01913 7e House Tightness: 798 CFMSO(2.19 ACH50) 978 270 391 1 M,. 6o=etVentilation: 56 CFM•8 Watts•Exhaust Only - so Duct Leakage to Outside: 57 CFM @ 25Pa(3.37/100 ft2) n _4, This Home Above Grade Walls: R-21 _ 99.1 - C. Sa Ceiling: Vaulted Roof,R-35fi w L C WindowType: U-Value:0.3,SHGC:0.25Zero Energye Foundation Walls: N/A Framed Floor: R-30 Paul Graney,Certified Energy Rater less Energy Digitally signed:6/8/23 at 4:44 PM 1).,:1 R11,11 0 ekotrope Ekotrope RATER-Version:3.2.33174 The Energy Rating Disclosure for this home is available from the Approved Rating Provider. Energy savings calculated without modifications to the energy model.(As Modeled) This report does not constitute any warranty or guarantee. RESNET COVID-19 REMOTE INSPECTION HOME ENERGY RATING Standard Disclosure For home(s) located at: 66 West Great Western Rd, Yarmouth, MA Check the applicable disclosure(s): :1.111.The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 742. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: IA. Mechanical system design I I B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel E. Other(specify) 3. The Rater or the Rater's employer is: DA. The seller of this home or their agent I I B. The mortgagor for some portion of the financed payments on this home C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products Installed in this home by OR is in the business of HVAC systems Rater 1 [Employer i [Rater !Employer Thermal insulation systems Rater 147 Employer Rater [ Employer Air sealing of envelope or duct systems riRater J Employer riRater Employer Energy efficient appliances Rater r Employer r Rater Employer Construction(builder, developer, construction contractor,etc) DRater [Employer Rater LEmployer Other(specify): NEAB /Rater DEmployer Rater rEmployer v 5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). Rater Certification#: 2649950 6. This home has been verified using RESNET's COVID-19 interim remote verification protocols. https://www.resnet.us/about/us/resnet-covid-19-updates/ Name: Paul Graney Signature: Paul Chaney, Organization: Home Energy Raters Digitally signed: 6/8/23 at 4:44 PM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 102.1.4.6 of the standard and are posted at https://standards.resnet.us The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Air Leakage Report Property Organization Inspection Status 66 West Great Western Rd Home Energy Raters 2023-06-08 Yarmouth, MA 02664 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered West Great Western Rd - kLZ1q5G2 Builder (Confirmed) West Great Western road 44 Starbuck General Information Conditioned Floor Area [ft2] 1,689 Infiltration Volume [ftl 21,818 Number of Bedrooms 3 Air Leakage Measured Infiltration 798 CFM50 (2.19 ACH50) ACH50 (Calculated) 2.19 ELA[sq. in.] (Calculated) 43.89 ELA per 100 s.f. Shell Area(Calculated) 0.714 CFM50 (Calculated) 798 CFM50/s.f. Shell Area (Calculated) 0.130 Duct Leakage System 1 Leakage to Outdoors 57 CFM @ 25Pa(3.37/ 100 ft2) Total Leakage Test Type Post-Construction Total Leakage [CFM @ 25 Pa] 57.0 Total Leakage [CFM25/ 100 s.f.] 3.4 Total Leakage [CFM25/CFA] 0.034 Mechanical Ventilation Rate[CFM] 56 CFM Hours per day 24.0 Fan Power 8 Watts Recovery Efficiency% 0.0 Runs at least once every 3 hrs? true Average Rate [CFM] 56.0 CFM 2010 ASHRAE 62.2 Req. Cont. Ventilation 46.9 2013 ASHRAE 62.2 Req. Cont.Ventilation 55.6 Ekotrope RATER-Version 3.2.3.3174 All results are based on data entered by Ekotrope users.Ekotrope disclaims all liabiity for the information shown on this report. Energy Code Inspection Checklist Property Organization Inspection Status 66 West Great Western Rd Home Energy Raters 2023-06-08 Yarmouth, MA 02664 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered West Great Western Rd -kLZ1q5G2 Builder (Confirmed) West Great Western road 44 Starbuck General Building Information Conditioned Area (sq ft) 1,689 Conditioned Volume (cubic ft) 21,818 Insulated Shell Area (sq ft) 6,144.3 The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab None Present Framed Floor Name: >basement(1,643 s.f.) R-0 continuous insulation, R-29.7 cavity insulation Insulation Grade: I I Name: >basement stairs(46 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: III Foundation Wall None Present Above Grade Wall Name: >ambient(1,479.3 s.f.) R-0 continuous insulation, R-21 cavity insulation Insulation Grade: I j-r Name: >basement stairs(254.7 s.f.) R-0 continuous insulation, R-15.05 cavity insulation Insulation Grade: I ` Name: >garage(224 s.f.) R-0 continuous insulation, R-21 cavity insulation Insulation Grade: I 1 Energy Code Inspection Checklist Property Organization Inspection Status 66 West Great Western Rd Home Energy Raters 2023-06-08 Yarmouth, MA 02664 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered West Great Western Rd -kLZ1q5G2 Builder (Confirmed) West Great Western road 44 Starbuck Name: gable walls (285.3 s.f.) R-0 continuous insulation, R-21 cavity insulation Insulation Grade: I Rim Joist None Present Ceiling / Roof Name: Slopes (2,212 s.f.) R-5 continuous insulation, R-30 cavity insulation Insulation Grade: I Opaque Door l Name: Front(20 s.f.) U: 0.184 EName: >basement(20 s.f.) U: 0.752 1 Name: >garage(18 s.f.) U: 0.140 Glazing Name: Front(60 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH_WEST Name: Front awnings(8 s.f.), U: 0.270, SHGC: 0.23, Orientation: SOUTH_WEST Name: Front shaded dh (6 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH_WEST Name: Right(35 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH EAST fl Name: Rear(79 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH_EAST Name: Rear ca (21.3 s.f.), U: 0.260, SHGC: 0.25, Orientation: NORTH_EAST 2 LI Name: Left(12 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH_WEST Energy Code Inspection Checklist Property Organization Inspection Status 66 West Great Western Rd Home Energy Raters 2023-06-08 Yarmouth, MA 02664 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered West Great Western Rd - kLZ1q5G2 Builder (Confirmed) West Great Western road 44 Starbuck Name: Left slider(41.5 s.f.), U: 0.300, SHGC: 0.28, Orientation: NORTH_WEST Skylight None Present Mechanical Ventilation Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 24 hrs/day, 8 Watts Mechanical Equipment t- Furnace(1)• Natural Gas• 100% Heating Load @ 95 AFUE AC (1) • Electric• 100% Cooling Load @ 16 SEER '—` Water Heater• Natural Gas• 100%Hot Water Loac @ 0.97 UEF Air Leakage Control Test Status: Blower-door tested House is air-sealed as to achieve 798 CFM50 (2.19 ACH50) or less at final blower-door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 2018 IECC Infiltration limit for the design home is 3 ACH50. 2021 IECC Infiltration limit for the design home is 5 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space,testing required Leakage to Outside specified as: 57 CFM @ :25Pa(3.37 /100 ft2) Total Leakage specified as: 57 CFM @ 25Pa (Post-Construction) 3 Energy Code Inspection Checklist Property Organization Inspection Status 66 West Great Western Rd Home Energy Raters 2023-06-08 Yarmouth, MA 02664 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered West Great Western Rd - kLZ1q5G2 Builder (Confirmed) West Great Western road 44 Starbuck Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25/ 100 sq ft CFA. Rough in Test with AHU:Total Duct Leakage <= 6 CFM25 /100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <=4 CFM25 /100 sq ft CFA. 2012 IECC Mandatory, 2015, 2018, &2021 IECC Prescriptive Paths: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25/100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <=3 CFM25 /100 sq ft CFA. Note: IECC 2021 requires Total Duct Leakage <= 8 CFM25 /100 sq ft CFA when all ducts and air handlers are within the building thermal envelope. 2015 and 2018 IECC Performance Paths (Cost Compliance): Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes Errors and Warnings have been Rater Reviewed 4