HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. r;L2- Lot ..J Zone of Contribution: In_ Out / Acreage i� Commercial: Residential: ...�-
Street: 1 `p //�_ , (�
Village: f > , Floor Plan: v' #Bedrooms:
Owner:
Installer: m , 30� i
Phone:Address:
Phone:
Builder: Engineer: i3 SC L^ ,
Address: Phone: F-w
Phone:
1. Required#of copies received N/A YES I NO
.,-----
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material; above water table :_i
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.:5. Water line 10 ft from septic components Var.:6. Benchmark indicated and shown-NGVD if near wetlands7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.. I �y
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: `
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: f V f
15. System not in top or subsoil (A;B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall: I
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel /-
21. No garbage disposal -
22. System adequately sized for its intended use I
23.Minimum 6"stone or compacted below tank and dbox I
24. Manhole covers within 6" of grade, pump chamber cover to grade /-
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes ,-----
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed r
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for-tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial:
•
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ��
33.H-20 loading is subject to vehicular traffic, groundwater /
34.Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house /'
36. Deed Restriction required max. #bedrooms: max. flow: gpd / "
37. Check area lots for groundwater/Label groundwater in Assessor's Map I I
Plan reviewed by: .______I_C.f ...>"--C.-.04 coo: