HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot
7.,‘ Lot 2 Zone of Contribution: In Out/ Acreage
.--, Commercial: Residential:
Street: ci 7 r.v C
Village: Floor Plan: r
Bedrooms:
Owner: Installer:�� , ( "
Address: Phone: h �' ��,
Phone:
Builder: Engineer: p Ai Address: g L /t �"
P
Phone:
Phone:
1. Required#of copies received N/A YES
/� I NO
2. Date of soils exam and percolation test not older than 2 years - ,V�
3. 4-5 ft of naturally occurring pervious material, above water table �t.---•"" -
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: "- -
5. Water line 10 ft from septic components Var.: 1
-
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: [i
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I I f .`
9. Leaching minimum 100 ft from wetlands Var.: I /
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: a
11. Tank/leaching minimum 10 ft from property line Var.: dam',
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: <
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable w /
17. System meets slope requirements- min. 1/8", 'A"preferred %
18. System meets breakout requirements PVC liner: Wall:
67
19. Specified tee sizes are proper, gas baffle on outlet tee (�
20. Sewage is under 10,000 gpd for parcel /
21.No garbage disposal w
22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade v
v
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size g/
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature I L�
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house „ ----
36. Deed Restriction required max. #bedrooms: max. flow: gpd /
1 37. Check area lots for groundwater/Label groundwater in Assessor's Map ,
Plan reviewed by: . '7 __/C.„. .._
c o,