HomeMy WebLinkAbout5038 184 South Sea Ave #10 Reinforcing Bar Locations and SizeBriggs Engineering & Tcsting A 0117SWN W 1'K AS:S00477:S. P C. Matt Feid. 184 S. Sea Ave. W. Yarmouth, MA January 31, 2023 PROJECT: 184 S. Sea Ave., Concrete Columns Supporting House Structure H10 RE: Scanning of Columns to Establish Reinforcing Bar Locations and Size As per your request, Briggs Engineering & Testing performed a scan of the existing concrete columns at the above noted property. The purpose of this scanning is to ascertain the location, spacing / lay -out and size of the reinforcing steel in the columns. Scanning was performed using our Humbolt Cover Meter. There are twelve columns in total. The columns are 16"X 16" and 5.5' in height. After scanning the exposed vertical surfaces on eleven of the twelve columns, the following observations were made. 1) there are four vertical bars in the columns, estimated to be #8 size at 4" deep. Note that the estimated bar size could differ by one bar size. See attached sketch. 2) Stirrup Bars estimated to be #4 size were noted to be positioned at an average of F LIP the Height of the columns at 4" deep from the scanning surface. Please see the attached sketch depicting the typical reinforcing in the columns examined. If you have any questions on these results or require further testing, please contact me at our Rockland, MA office. Thank Y 7i.Very Much, _L Kevin M. Curran Director, Structural Dept. rit;( wilLtineerint;.(-ont 14) ,vL'''11) Ith �[I-CCI - l!nii C'-? 100 Ponnd Road RocI:Luid. NIA 02370 Ciwlhrrlandl R1 02864 Phone (781) i7l-6040 • Fax (781) 871-4340 Phone (401) 658-2990 • Fax (401) 658-2977