Loading...
HomeMy WebLinkAbout22 Willow Ln title VLEGEND 99 --- EXISTING CONTOUR X 39.9 EXIST. SPOT ELEV. --(99�-- PROPOSED CONTOUR 198•41 PROPOSED SPOT EL. TH1 10� TEST HOLE 2,.- SLOPE OF GROUND UTILITY POLE FIRE HYDRANT Na1E: NOT ALL SYMMS MY APPEAR IN WAWMiB SYSTEM PROFILE (NOT TO ` PROVIDE INSPECTION PORT TO GRADE ALL SYSTEM COMPONENTS SHALL BE 4" SCH40 PERFORATED PVC DOWN TO DRILL LAST HOLE IN EACH MARKED WITH MAGNETIC TAPE OR SAND AT BOTTOM LEACHING FIELD, LATERAL ON TOP TO VENT COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE MIN. 20" DIAM. WATERTIGHT PROVIDE 4" THREADED COVER AND AIR WHILE LATERAL FILLS ACCESS COVERS TO WITHIN 6" OF FIN. GRADE LEBARON LA910 CAST IRON ACCESS RETAINING 32 PORT H-20 CONSTRUCTION. FEMALE ADAPTOR &THREADED PLUG WALL TOP FOUN .g Ems; 10.0' 2"0 THREADED END CONNECTION MINIMUM J OF COVER OVER PRECAST 2X SLOPE REQUIRED OVER 9.5' SCH 4D PV DETAIL) iPRECAST H-10 1/4" SHIELDED 8.68' ORIFICES _ .z RISERS (TYP.) 2 o INV. 8.55' 2" INVERTS LEVEL AT 6.05' _ e� 2" PRESSURE LINE ' � d� C opL o 8,05' 2500 GAL H•-10 - "y �*7± 10" SEPTIC TANK/ ORIFICES 5 ON CENTER 6.88' TEE PUMP CHAMBER ;. COMBINATION BOTTOM LEACHING LEVEL AT EL. 8.05' 2" CENTRAL FED MANIFOLD SEE DETAIL BELOW WEEP HOLE PITCH TO DRAIN BACK TO •. 7. PUMP CHAMBER- NO LOW SPOTS. 5" i ° ° O ao°o°o°o°o°°o°°aaa°o°a°O°o°o°O°O°O°O o° " 2" DOUBLE WASHED STONE 0 o a a o o a a o 0 0 0 0 0 0 0 0 a a o 0 ^+°a°a°o°s•°anna'�° ti°n°o°o°a°o°°0 o o°o°- 3/4TO 1. 1/ SIDE ELEVATION VIEW *THE INSTALLER SMALL VERIFY THE 6" CRUSHED STONE OR MECHANICAL LOCATIONS OF ALL UTILITIES AND ALL COMPACTION. (15.221 [21) BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY (2.5X SLOPE MIN.) PORTION OF SEPTIC SYSTEM WATERPROOF 34, LEACHING FOUNDATION 13 SEPTIC TANK FACILITY ,SAWCUT AND S8fi 2 tOO"E �_�,� ,__)� PATCH 8& �� 1 i5,52 -Sg6'23 0 AS REG. ADJUSTED s ...-- ••"-.. j' ` •_ _ r 0 E • ' 2% MIN. SLOPE OVER SYSTEM c0 .! 95.52 f 4" LOAM & SEED APPRX ___ __- ``• �VILLO 30" CAP STONE UNITS W�. } ,` �. 1 /2" x 5 1/4" REQUIRED AROUND OF UNSUITABLE PERIMETER OF M IN SBC� 2�.3-'�'r M - -- - LA � \ " 9 ABUTTERS t Fiberglass LEACHING FACILITY, DOWN TO CS `* .54 9 COVER �`=It Pins ��` L 1 =tt SUITABLE SOIL LAYER. REPLACE DRIVE T� �,- i`' Ira �\ al $ + Vr NTH CLEAN MED. SAND, TO MEET i } } --> f�� IISr 1'MIN. 3_5' MAX. SPECIFICATIONS OF 310 CMR ` 6" VARIE 15.255(3) ...r+" "! .3 OWNER'S ENGINEER SHALL. PROVIDE: 1. STAKING OF PROPOSED RETAINING WALL LOCATION 2. SOIL INSPECTION 3. PUMP SYSTEM INSPECTION 4. FINAL INSPECTION AND CERTIFICATION OF ALL COMPONENTS PRIOR TO BACKFILUNG A MINIMUM OF 24 HOURS NOTICE IS REQUIRED DCE #21--326' 11 Scale:l"= 20' 0 10 1{J 3[11 40 0 F F. I. PEASTONE COARSE SAND BACKFILL AGAINST WALL r•= 40 MIL LINER FROM TOP PEASTONE/WALL a TO 12" BELOW GRADE KEYSTONE OR EQUAL RETAINING WALL UNITS 6"X30" Crushed Racy or 18"X8" SET NTH 1" BATTER PER ROW Unreinforced Concrete FIBERGLASS PINS REQ. Leveling Pad req. RET&II. r9.,wWSj/'y'�� ; L R(/'�/VSS KUM. NOT TO SCALE 20 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4,/'10 HP PUMP CLEANOUT (TYP.) 21.5' � 4 INSPECTION PORT TER EL. 3.05 SYSTEM DESIGN: NOTES Yarmouth Conservation Conditions: 1. A hard copy of the plan shag be provided to the Conservation 1. DATUM IS A� 88 GARBAGE DISPOSER IS NOT ALLOWED Administrator for review. An electronic copy of the final plan shall be provided to kgrant@i yarmouth.ma.us, 2• MUNICIPAL WATER IS EXISTING EXISTING 3 BEDROOM DWELLING 2. The proposed sewage disposal system shall meet the applicable Title 5 wetlands setbacks as set forth by the Health Department. "work 3. MINIMUM PIPE PITCH TO BE 1 /8' PER FOOT. 3. A limit" line shall be established with Erosion Controls (i.e DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD straw bales, staked filter fabric, bark mulch, `silt sacks," products 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO made with rice straw, and other weed -free products or approved by BE AASHO H-1Q USE A 330 GPD DESIGN FLOW the Corivnission.) Hay bales are not allowed. It is the applicant's responsibility to implement and maintain appropriate and adequate erosion controls measures throughout the construction process: 5• PIPE JOINTS TO BE MADE WATERTIGHT. SEPTIC TANK: 330 GPD 2 = B60 ( 4• No work of any kind shall occur on the Resource Area side of the work limit line. This tine shall be established prior Ltt any 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH USE A 2500 GAL. SEPTIC TANK/PUMP CHAMBER COMBINATION construction or work. 310 CMR 15.000 (TITLE 5.) LEACHING: 5. All imported fill shall clean and not contain any foreign debris such as cement, bituhi in minous concrete, rubber, metal, trash, 7, THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO boulders, etc. BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 330 GPD (.74) = 446 SF REQUIRED 6. Debris, including fitter, shall be picked up immediately. Any excess material that is excavated from the job site shall be disposed of at 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40--4' PVC. 21' X 21.5' = 451.5 SF OK a location approved by the Conservation Administrator or in a 451,5 SF X = 334 GPD OK covered dumpster. No debris shall be allovved in a Wetland or 9. COMPONENTS NOT TO BE BACKFILL.ED OR CONCEALED ,74 Waterway. WITHOUT INSPECTION BY BOARD OF HEALTH AND r r USE A 21 X 21.5 PRESSURE DOSED PIPE AND STONE 7. Washing of equipment/tools shall be done OFF -SITE or handled in PERMISSION OBTAINED FROM BOARD OF HEALTH. LEACHING FIELD a me nner approved by the Conservation Administrator. &. No equipment shall be refueled, nor shalt fuel be stored within 100 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING feet of a resource area. DIGSAFE (1 •-888-344-7233) AND VERIFYING THE LOCATION 9. The cesspool is to be pumped dry, the connection broken, and OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO filled with clean sand. COMMENCEMENT OF WORK MA 10_ Any area that is disturbed during construction shall be revegetated immediately or as soon after as the growing season commences. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE LOCUS ��� MAP APPROVED DATE BOARD OF HEALTH Permanent stabilization shall be carried out in order to nvnirrize erosion. REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. SCALE 1 "=2000't 12. EXISTING PUMP PIT AND LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH ASSESSORS MAP 42 PARCEL 125 ORIFICE SHIELD OS200 CLEAN SAND. ORENCO SYSTEMS INC 13. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL. 11) 2.0"0 SCH-40 PVC LATERAL PH. 1-800-348-9843 FOR ZABEL FILTER. INSTALLER MUST FOLLOW AS SHOWN ON COMMUNITY PANEL #25001CO589J OR EQUAL. MANUFACTURER'S SEPCIFICATIONS FOR PROPER FILTER DATED 7f16/2014 INSTALLATION. 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. 15. LOT UNE AND PROPOSED WALL TO BE STAKED PRIOR 1/4-0 HOLE AT 5' O.C. SNAP -ON {__- TO ANY WORK ON SITE, -�:�__ ALTERNATE BETWEEN TOP SHIELD J 16. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE & BOTTOM OF PIPE_ FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE EXACT DIAMETER HOLES �`-? DRAINAGE SLOTS REQUIRED. TEST HOLE LOGS SHOULD BE SHOP DRILLED WITH 17. WETLAND FLAGGED BY PAUL SHEA OF INDEPENDANT A DRILL PRESS TO ENSURE ENVIRONMENTAL CONSULTANTS. UNIFORMITY. REMOVE BURRS ENGINEER: DANIEL E. GONSALVES, SE #13587 PRIOR TO PLACING PIPE. 18. EXISTING WATER MAIN DRAWN PER AS BUILT ON FILE AT THE TOWN WITNESS: PHIL RENAUD ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 6.88' SEPARATE CIRCUIT FROM PUMP ZABEL FILTER - FLOAT SWITCH ALARM ON (A1Q0) OUTLET TEE W/EX1 SETTINGS: PUMP ON 5" WORKING RANGE 6" 5.. PUMP OFF 12" ,q"a,kkirrnLu r n 2" PRESSURE PIPE BACK TO ST/PC 2" LATERALS 5' Q.C. Y4„ ORIFICE SHIELD 5' O.0 EA Cl- ING DETAIL (I ,7` 1 D UNFINISHED FAMILY ROOM WATERTIGHT ACCESS COVERS TO GRADE 900 GAL.+ THIS SIDE 440+ GAL RESERVE PROVIDE QUICK DISCONNECT FOR PUMP 2" PRESSURE LINE VSION _ 0.25" WEEP HOLES MIN. 1500 GAL_ rot CHECK VALVE THIS SIDE k r MYERS SRM 4 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 7.8') REDUCTION IN SETBACK. ST TO LOT LINE (10' TO 6.5') 0b): REDUCTION IN SETBACK. ST TO FOUNDATION (10' TO 7.3') (th): REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' 15.555 (5): REDUCTION IN LATERAL REMOVAL OF UNSUITABLE MATERIAL (5' TO 1') UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: (3.7): REDUCTION IN SETBACK, SAS TO BVW (100' TO 55.1') REDUCTION IN GROUNDWATER ADJUSTMENT (2.05' TO 1.05') OF BAFFLE SUBMERSIBLE 4/10 HP PUMP SYSTEM (OR EQUAL) BUOYANCY CALL: (ON BLOCK) 2500 H-10 TANK WEIGHT: 22,560 LBS � coo WATERPROOF 6" BAFFLE 11.83 x 6.33 x 2.2 x 62.4 = 10,280 UP OK 2500 GAL. SEPTIC TANK/ ACCESS FOR ROUTINE MAINTENANCE ( ) PUMP CHAMBER COMBINATION MUST BE PROVIDED FOR ZABEL (NOT TO SCALE) FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION ZONING SUMMARY ZONING DISTRICT- RS-40 RESIDENTIAL DISTRICT LIVING ROOM MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' DINING MIN. REAR SETBACK 20' 5`�� MAX. BUILDING COVERAGE 25% 1ST FLOOR PLAN (N.T.S.) 0 W V) BATH STAIR Z N 2ND FL DOR PLAN PROPOSED 2ND FLOOR PL A N (N.T.S.) (N.T.S.) Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approva4 is required for any future add itions%renovations/aIterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED Name Date tNCFMgs , �ZttOt 1!gSS9n DANIEL A DANIEL yes OJALA A. " CIVIL " c� OJALA rA n No.46502 q No. 40980 G r s T E� Paw S\0 Y°'9roniat DATE DANIEL A. OJALA, P.E., P.L.S. DATE: 10/28/21 PERC. RATE = < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 7.5' 24" / 30" 1 OYR 3/ 1�/5 0' f 36" � /10YR 4/6 19.5' UNSUITABLE C G-W ADJ. DATA: SOIL SIEVE M/CS ZONE: A WELL: A 29 2.5Y 7/4 ADJ: 2.05' OCTOBER 2021 114" -2.0' GROUNDWATER ENCOUNTERED AT 66" EL. 2.0 TITLE 5 SITE PLAN OF 22 WILLOW LANE YARMOUTH, MA PREPARED FOR JACK ARENA DATE: JANUARY 13, 2022 REV.: FEBRUARY 18, 2022 (STONES FOR MOWING LIMIT) REV.: MARCH 17, 2022 (RELOCATE SEPTIC, ADD WATER FAIN) off 508-362-4541 fax 508-362-9$80 downcope_com 0 down► cope e�n i ae�WI. i�c. ff civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 21-326 ARENA.DWG