HomeMy WebLinkAboutReview Checklist 70 -o 1-1 TOWN OF YARMOUTH
,_ - SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. LI D Lot . Zone of Contribution: In Out Acreage • 23
Commercial: Residential:
Street: . 2D �1MIMGVG1k1 2,1``_ .
Village: ,S. yitiV6/44-14Floor Plan: #Bedrooms: N.S/Ac
Owner: ( ,r' Ohl I Installer:
Address: P(U&D( 1210 �f Phone:
Phone: yk 1444 Q fi .02(p 1D 1
Builder: Engineer: V5e
Address: Phone:
Phone:
N/A YES NO
jct,'Required#of copies received v �/
, ate of soils exam and percolation test not older than 2 years '0 ,3 e j'
3. 4-5 ft of naturally occurring pervious material, above water table 1
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: ,/
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: > ,
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t./'
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: •/ !
14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: V/ .,
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable ✓ -
17. System meets slope requirements-min. 1/8", V4"preferred . t..--'
18. System meets breakout requirements PVC liner: Wall: 1/
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal //
22. System adequately sized for its intended use 'I
23.Minimum 6"stone or compacted below tank and dbox t/r
24.Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size
.Z8. Septic tank/pump chamber to be factory waterproofed
U
�2�Vent provided if leaching below 3 feet, under driveway/parking 6i''C
uoyancy calculations for tank/pump chamber ✓
ngineer to inspect and certify soils: wall: commercial: , V �v../ /�
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature �'
33. H-20 loading is subject to vehicular traffic, groundwater l j
_ 34. Title V Application and permit fee, installer sign ture :..--
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd ✓
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: / l kL_ 6/03/03
lcl j00b1 20u