Loading...
HomeMy WebLinkAbout1 Windswept Path plan 5H2.5A (4) 11 Z" x 1 J" LVL TO SPAN 16'--\ 2 x 8 NAILER W/ (2) LEDGERLOK @ STUDS W/LSSU28 2 x 8 ROOF RAFTERS @ 16" O.C. 11-011 H2.5A (3) 2 x 10 BEAM 2x8@16"O.C.— 5'-0" 3'-1 " 101-0 �4_ 4" T&6 PLYWOOD SUB -FLOOR CLG TO REMAIN 9.5" TJ1230 @ 16" D.C. 8y4„ 3'-„ 5'-011 VERIFY BLOCK JST. OVER EXT. WALL 00, 13'-3%" APPROX. SECTION C-C SCALE:1/4"=1' -6'-1 Y4" H2.5A I I I`—ABU BASE W/8" 2 x 8 NAILER W/ (2) (2) 2x12 W/ 2x8 FULL LENGTH OF 4,-0„ I I ANCHOR BOLT LEDGERLOK 16" O.C. PORCH (TYP. BOTH PORCHES) W/LU28 L —8" BF24 BIGFOOT FOOTING 5'-10" OPT. FRONT PORCH SECTION SCALE:114"=1' 10'-0" EXISTIN x HANDRAILINGS TO BE INSTALLED PER CODE 36" MIN. HEIGHT CONT. RIDGE VENT TYPICAL (2) 2x12 RIDGE BEAM 12 a8 -10'-8y2" 2x10@16"D.C. (2)11.875" LVL BEAM x ±16' SPANNING OPEN AREA FLUSH ON BOTTOM. 2 x 8 NAILER W/ (2) (3) 2 x 8 HEADER LEDGERLOK @ STUDS TYPICAL U.N. WASSU28 6'-10y2„ 6'-1 /4" 8,_1y8„ TYP. HEADER 2 x 6 EXT. NEW HEIGHT WALLS _ 4" T&G PLYWOOD SUB -FLOOR 9.5"x 3.5" LVL BEAM 9.5" T11230 @ 16" O.C. CUSTOM BUILT STAIRCASE: MANUFACTURER TO PROVIDE ATTACHMENT HARDWARE 2 2 x 10 BLOCKING (3) 2 x 10 BLOCKING T AT BASE OF STAIRS AT EACH COLUMN 14'-1y2 n 1'-211 —151-3y211 (7) 3 }'STEEL TALLY COLUMN (7) 20" x 20" x 10" CONCRETE FOOTING 26'-0" EXISTING I I I I I i t I I i t I I I I I 7'-611 7'-6" SECTION D-D SCALE:1/4"=1' SECTION A -A SCALE:1/4"=1' 2x6 EXT. W OPTIONAL REAR PORCH m 11-0 11 (3) 2 x 7'--A'//Z 71-0�411 VERIFY (2) 2x10 W/ 2x8 FULL LENGTH OF PORCH (TYP. BOTH PORCHES) II 2 x 8 NAILER W/ (2) i i I LEDGERLOK 16" O.C. l W/LU28 i�--5'-10" BALLOON FRAME GABLE WALL 2x10 ROOF RAFTERS @ 16" O.C. 16'-011 BA HANGERS TYP. (2) LEDGERLOK @ 16" O.C.— 2) 2x8 P.T.BEAM �' SUB -FLOORING 2x10 NAILER—� P.T.2x10 @ 16" O.C. SIMPSON LU210 / 411" i 4" P.T. PLYWOOD I HANGER TYP.—/ MIN. ABU66 "(4, (6) 10" BF24 x 48"H L — — ANCHOR BOLTS L — BIGFOOT FOOTING 7'-9" 7'-911 SECTION E-E SCALE: 1/4"=1' CONT. RIDGE VENT TYPICAL (3)14'x3.8LVL RIDGE BEAM 12 8 1a 2x10@16"O.C. 1'-011 H2.5A BALLON FRAME GABLE WALL 8'-1y8" 8'-4" (2) #4 REBAR CONTINUOUS 2" CLEAR MIN. TYPICAL 1 4'-0" 1011 8 EXIST. 2x4 EXT. WALL EXIST. 4" SUB -FLOORING EXIST. 2x10 FLOOR JOISTS 10" EXIST. FOUND. 5u 9'-611 8'-1�8" 8'-11/8"� 4'-7y8„ O 9.5" TJ1230 @ 16" D.C. 5'-0„ 2 x 6 EXT. NEW f" T&G PLYWOOD WALLS SUB -FLOOR 9.5" x 1.25" LVL RIM BOARD (3) 14" x 11 j LVL BEAM (3) 1 j" x Ili LVL HEADER SEE APA PORTAL, SK.2 W/ CODE CHK. LIST WIND BLOCKING: 2 BAYS @ 4' O.C. EACH LEVEL TYP. J" O ANCHOR BOLTS @ 24" CTRS w/ 3x34' PLATE WASHER TYP. NEW FOUNDATION L — J (3)#4 REBAR CONTINUOUS 3" OFF BOTTOM OPTIONAL $" FIRE -CODE DRYWALL INSTALLED ON CEILING & 3.5" STL. LALLY COLUMN COMMON FRAMED WALLS IN ON 24" x 24" x 10" FTG. GARAGE, PER INT. CODE R302.6 4" CONCRETE SLAB ON A 10 MIL VAPOR BARRIER OVER 6" COMPACTED GRAVEL BASE SLOPED" PER 12" TOWARDS DOORS -8'-0" 24'-0' SECTION B-B SCALE: 1/4"=1' N. (2) #4 REBAR CONTINUOUS 2" CLEAR MIN. TYPICAL OF h4A r MICHELE CUDILO O No, 34774 STRUCTU w jv 9/23/22 FOR STRUCT. ONLY NOTES: 1. SEE CODE CHECKLIST FOR SPECS, ETC,