HomeMy WebLinkAbout379 Weir Rd plan 2mill 1111 RISERS r17 ±7%" RIS BEARING WALL 4" CONCRETE SLAB WWF Gx6 GIG TOP Y4 OF SLAB 24"W.x12"D. CONCRETE STRIP FOOTING 2-#5 BARS CONTINUOUS —\ FIRST FLOOR VERIFY FOOTING IS ON COMPACTED GRANULAR FILL OR UNDISTURBED GRANULAR SOILS w/ NO CLAY, PEAT, LOAM, VEGETATIVE MATERIALS. I NT. BEARING WALL AT FOOTING 11 1 SCALE 1 /211_1 1-01Y IO" THICK x ±8'-10" CONCRETE WALL ON CONTINUOUS 20"x10" CONCRETE FOOTING (VERIFY HGT. w/GRADE) B A.5 A A.5 0 r-T-T-T-(T 71-611 71-(o't SECOND FLOOR - --T- �i- - ------------- ------- -------------, II-------- /B% I I 10" THICK x ±8'-10" 1 A.2 j h - - - - - CONCRETE WALL ON i° 0 L-------------I----------- CONTINUOUS 20"x1011 I p L 2xG BEARING WALL ON CONCRETE FOOTING I G INUOUS (VERIFY HGT. w/GRADE) 11 1_ STRIP2FOOTCONTINUOUS 12 _ 8�4 5 8Y4 I w/2-#5 CONTINUOUS BARS. I i I I 41lx 4"x . 25" _ I 'I I TUBE STEEL COL. I f0" THICK x ±8'-10" VERIFY IN FIELD: 3/a' x6"x 12" STEEL BASE PLATE 4 { +1 I CONCRETE WALL ON s t LOCATION OF 3 2—/4 DIA. ANCHOR BOLTS I CHANGE IN WALL HGT. ` CONTINUOUS 20"AO" A.3 ON 3G"X36"X12"D I FOR GRADE CHANGES .I I CONCRETE FOOTING I CONCRETE FOOTIING I I (VERIFY HGT. w/GRADE) °I I I I" DEEP CONTRACTION I j I 14 JOINT CUT WITH EARLY I I - - - -I ENTRY SAW , - ------------------- {---------------------------------------- I I A o om •I A.5 5/8" ANCHOR BOLTS @ 24" O.C. I 1 I I MINI 7EMBEDMENT GARAGE •I I VERIFY IN FIELD: w/3 x31 xl/4IPLATE WASHER LOCATION OF 4" CONC. SLAB ON °I I CHANGE IN WALL HGT. I 6 MIL VAPOR RETARDER 10" THICK x W-8" I FOR GRADE CHANGES CONCRETE WALL ON _ I o I CONTINUOUS 20"xl0" I .I I I CONCRETE FOOTING I I o cv +1 I I I SLOPE SLAB 16" PER FT. N I DROP FOUNDATION I TOWARDS DOORS xx WALL AT DOOR I I _ I 10' THICK x 4'-8' ' +1 I CONCRETE WALL ON I 411x4"x .25" CONTINUOUS 20"x1011 TUBE STEEL COL. I 5/a"x6"x 12" STEEL CONCRETE FOOTING I I. .I BASE PLATE: f I I I 4 Ln FOUNDATION 2-3/4" DIA. ANCHOR DROP I BOLTS DROP FOUNDATION A.3 WALL DOOR I L — — — — — — — — — 1— WALL 12" AT DOOR— .I — — APRON � � — DROP LL +[20UAND>A�T�I—O,� — I' -q" q'-G" 4'-011 G'-G" 41_011 g1_61 Lit -Gill FOUNDATION PLAN 2 A.3 FOUNDATION NOTES 1. MAIN FOUNDATION WALLS TO BE 10" POURED CONCRETE fc'=3000 psi, W/ 2@ #5 BARS TOP 4 BOTTOM. FOUNDATION WALL TO BE ON 20"xl0" STRIP FOOTING, PROVIDE 3@ #5 HORIZ. BARS CONTINUOUS IN STRIP FOOTING W/ KEYWAY. PROVIDE 5/a" ANCHOR BOLTS @ 24" O.C. MAX. MIN. 7" EMBEDMENT W/ 3"x3"xY4" PLATE WASHER. 2. STRUCTURAL STEEL COLUMNS TO BE 4"X4"X.25" TUBE STEEL COL, 5/s11X6"X12" STEEL BASE PLATE t 2-3/4" DIA. ANCHOR BOLTS, WELD ALL CONNECTIONS, 3. DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS. 4. CONCRETE SLAB TO BE 4" POURED CONCRETE ON COMPACTED FILL. PROVIDE CONTRACTION JOINTS I" DEEP AT COLUMN LINES. CUT W/ "EARLY ENTRY" SAW. 5. CONTRACTOR SHALL ENSURE THAT ALL FOUNDATION WALLS MAINTAIN 4'-0" MINIMUM COVER. 6, PROVIDE WEB STIFFENING PLATES AT BEARING POINTS OF STEEL BEAMS (TYP.). 7. SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STRUCTURAL COLUMNS. 8. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. ANY MISSING, INCORRECT OR QUESTIONABLE DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER BECOME THE RESPONSIBILITY OF THE CONTRACTOR. SQUARE FOOTAGE GARAGE 1200 SECOND FLOOR LIVING 515 TOTAL AREA 1715 General Notes Andersen 400 TW series windows shown or provide similar. exterior walls to be 2x6 16" o.c. unless otherwise noted. interior walls to be 2x4 16" o.c. unless otherwise noted. verify all window and door rough openings prior to ordering. THESE PLANS ARE IN COMPLIANCE WITH THE WIND ZONE REQUIREMENT FOR 780 CMR 9th EDITION MA. STATE BUILDING CODE L ' c- C N O L 0 O O c 0)O06 O - O (D (D 5 '0 -0a)w , c: 05 � 06 M w N N N � Q QNN N I-o LO '-- C) 06 VJ _ � /� +-� E aa) o CU o O CL 0 w U 0 J_ m U W T E p O �� m • can Q .o a U)WQ� Q V Q W d <�/ o W O CL 0'CL ���// LLB LL C r<n V � CO !-> W z Q -j < i CL .3 n c r W O z O 00 OJT J LL 0 r) z z O ::) �(.) O w = LL W LL SCALE: 1 /8" = 1'-0'1 0 1 2 4 8 SHEET A.2 011 F 5 1 PROJECT: DATE: 21-900 9-14-2021