Loading...
HomeMy WebLinkAbout379 Weir Rd plan 4L N O sr 0 STANDING SEAM 0)o METAL ROOF NOTE: +O ._ >0N� 5/a" CDX PLYWOOD PROVIDE RAFTER VENTS O T cl) AT VAULTED CEILINGS N .� X W 0 15# FELT PAPER RIDGE STRAPS c -00 E m TYPICA VERTICAL SIDING SIMPSON N2.5A EACH OPTIONAL w/COLLAR N N RAFTER TIES Iw- Q N N TO PLATE CONNECTION RIDGE VENT Q N dam' TYVEK HOUSE WRAP o o ALUMINUM o 0 0 DRIP EDGE °00 RIDGE BEAM Y2' CDX PLYWOOD (SEE PLAN FOR SIZES) - -- 2"x6" FRAMING 16" O.G. STANDING SEAM • METAL ROOF R-20 FIBERGLASS • 5/a" CDX PLYWOOD C INSULATION 15# FELT PAPER cp 6 mil. POLY VAPOR BARRIER CEILING JOIST ALUMINUM GUTTER CL Y2" GYPSUM WALL BOARD R-4cl INSULATION 2"x10" RAFTERS 16" O.C. (UNLESS NOTED OTHERWISE) V 0 Ix FASCIA -ice-•+ N 0 RAFTER STRIP VENT Y2" GYPSUM BOARD w C) Ix SOFFIT 0 Ix STRAPPING 16" O.C. J 5 m DOUBLE TOP PLATE Ix10 FRIEZE TYPICAL WALL ^, U Ln •^' �ID E TYPICAL WALL TYPICAL EAVE TYPICAL RIDGE Q 1 � v � � � � � _� 1 n— r n 1 rr r n r n � �+-+ N SCALE1/2 -1-0 — SCALE1/2 -1-0 n— SCALE 1Y2 -1-0 p o �. NAILING SCHEDULE U w JOINT DESCRIPTION NUMBER OF NUMBER OF NAIL SPACING I!z 0 COMMON NAILS BOX NAILS CEILING JOIST CEILING JOIST ROOF FRAMING R-30 INSULATION R-30 INSULATION BLOCKING TO RAFTER (TOE NAILED) 2-8d 2-10d EACH END RIM BOARD TO RAFTER (END NAILED 2-16d 3-16d EACH END Q WALL FRAMING r^ Q � TOP PLATES AT INTERSECTIONS (FACE NAILED) 4-16d 5-16d AT JOINTS < 1-- STUD TO STUD (FACE NAILED) 2-16d 2-16d 24" O.C. w V ° HEADER TO HEADER (FACE NAILED) 16d 16d 24" O.C. ALONG EDGES w a ° o ° o ry w FLOOR FRAMING ° a < 0 JOIST TO SILL, TOP PLATE OR GIRDER (TOE NAILED) 4-8d 4-10d PER JOIST ti ° - - BLOCKING TO JOIST (TOE NAILED) 2-8d 2-10d EACH END U L3/4" BLOCKING TO SILL OR TOP PLATE (TOE NAILED) 3-16d 4-16d EACH BLOCK T$G PLYWOOD SUB -FLOOR GLUED STEEL BEAM 3/4" TtG PLYWOOD SUB -FLOOR GLUED w AND NAILED TYPICAL WRAPPED w/5/S" AND NAILED, TYPICAL LEDGER STRIP TO BEAM OR GIRDER (FACE NAILED) 3-16d 4-16d EACH JOIST O STEEL BEAM TYPE "X" FIRE JOIST ON LEDGER TO BEAM (TOE NAILED) 3-8d 3-10d PER JOIST WRAPPED w/5/S" „ 2x12 FLOOR JOISTS 16 O.0 CODE GWB „ 2x12 FLOOR JOISTS 16 O.0 BAND JOIST TO JOIST (END NAILED) 3-16d 4-16d PER JOIST TYPE "X" FIRE BAND JOIST TO SILL OR TOP PLATE (TOE NAILED) 2-16D 3-16d PER FOOT CODE GWB ROOF SHEATHING 5/g" TYPE "X" FIRE CODE GWB ENTIRE 5/8" TYPE "X" FIRE CODE GWB ENTIRE GARAGE $ CEILING GARAGE $ CEILING WOOD STRUCTURAL PANELS Y2" GYPSUM IF NO LIVING AREA ABOVE Y2" GYPSUM IF NO LIVING AREA ABOVE J Ix STRAPPING 16" O.G. Ix STRAPPING 16" O.C. RAFTERS OR TRUSSES SPACED UP TO 16" O.C. 8d 10d 6" EDGE/6" FIELD RAFTERS OR TRUSSES SPACED OVER 16" O.C. 8d 10d 4" EDGE/6" FIELD W DROPPED STEEL BEAM FLUSEEL BEAMdi GABLE ENDWALL RAKE OR RAKE TRUSS w/o GABLE OVERHANG 8d 10d 6" EDGE/6" FIELD 0 _ 2"xB" NAILING SLEEPERS BOLTED TO 21'x8" NAILING SLEEPERS BOLTED TO GABLE ENDWALL RAKE OR RAKE TRUSS w/ STRUCTURAL 8d 10d 6" EDGE/6" FIELD �n TOP AND BTI�I. FLANGES TOP AND BTM. FLANGES OUTLOOKERS V GABLE ENDWALL RAKE OR RAKE TRUSS w/ LOOKOUT BLOCKS 8d 10d 4" EDGE/4" FIELD Z BLOCKING BLOCKING "— CEILING SHEATHING OPTIONAL: CCn n /`yIV1 n CCG L BEAM FLUSH STEEL GYPSUM WALLBOARD 5d COOLERS - 7" EDGE/10" FIELD I-- W m WALL SHEATHING _ STEEL BEAM TO FLOOR CONNECTION WOOD STRUCTURAL PANEL lo STUDS SPACED UP TO 24" O.C. 8d 10d 3" EDGE/12" FIELD 1 rr - r rr SCALE 1 /2 — 1 -0 SCALE: 1 /8" = 1 `-0" Y2' AND 2V32' FIBERBOARD PANELS 8d - 3" EDGE/6" FIELD Y2' GYPSUM WALLBOARD 5d COOLERS 7" EDGE/10" FIELD 0 1 2 4 8 FLOOR SHEATHING SHEET WOOD STRUCTURAL PANELS 1" OR LESS 8d 10d 6" EDGE/12" FIELD A OF 5 GREATER THAN 1" 10d 16d 6" EDGE/6" FIELD .4 PROJECT: DATE: 21-900 9-14-2021