HomeMy WebLinkAbout379 Weir Rd plan 4L
N
O
sr
0
STANDING SEAM
0)o
METAL ROOF
NOTE:
+O ._
>0N�
5/a" CDX PLYWOOD PROVIDE RAFTER VENTS
O
T cl)
AT VAULTED CEILINGS
N .� X
W
0
15# FELT PAPER
RIDGE
STRAPS
c -00
E m
TYPICA
VERTICAL SIDING
SIMPSON N2.5A EACH
OPTIONAL w/COLLAR
N N
RAFTER
TIES
Iw-
Q N N
TO PLATE CONNECTION
RIDGE VENT
Q
N dam'
TYVEK HOUSE WRAP
o o
ALUMINUM o 0
0
DRIP EDGE °00
RIDGE BEAM
Y2' CDX PLYWOOD
(SEE PLAN FOR SIZES)
- --
2"x6" FRAMING 16" O.G.
STANDING SEAM
•
METAL ROOF
R-20 FIBERGLASS
•
5/a" CDX PLYWOOD
C
INSULATION
15# FELT PAPER
cp
6 mil. POLY VAPOR BARRIER
CEILING JOIST
ALUMINUM GUTTER
CL
Y2" GYPSUM WALL BOARD
R-4cl INSULATION
2"x10" RAFTERS 16" O.C.
(UNLESS NOTED OTHERWISE)
V 0
Ix FASCIA
-ice-•+ N
0
RAFTER
STRIP VENT
Y2" GYPSUM BOARD
w C)
Ix SOFFIT
0
Ix STRAPPING 16" O.C.
J
5
m
DOUBLE TOP PLATE
Ix10 FRIEZE
TYPICAL WALL
^, U Ln
•^' �ID
E
TYPICAL WALL
TYPICAL
EAVE
TYPICAL RIDGE
Q 1 �
v
�
�
�
�
�
_�
1 n— r n
1 rr r n
r n
� �+-+
N
SCALE1/2 -1-0
—
SCALE1/2 -1-0
n—
SCALE 1Y2 -1-0
p
o
�.
NAILING SCHEDULE
U
w
JOINT DESCRIPTION
NUMBER OF
NUMBER OF
NAIL SPACING
I!z
0
COMMON NAILS
BOX NAILS
CEILING
JOIST
CEILING JOIST
ROOF FRAMING
R-30
INSULATION
R-30 INSULATION
BLOCKING TO RAFTER (TOE NAILED)
2-8d
2-10d
EACH END
RIM BOARD TO RAFTER (END NAILED
2-16d
3-16d
EACH END
Q
WALL FRAMING
r^
Q
�
TOP PLATES AT INTERSECTIONS (FACE NAILED)
4-16d
5-16d
AT JOINTS
<
1--
STUD TO STUD (FACE NAILED)
2-16d
2-16d
24" O.C.
w V
°
HEADER TO HEADER (FACE NAILED)
16d
16d
24" O.C. ALONG EDGES
w
a
°
o °
o ry
w
FLOOR FRAMING
°
a <
0
JOIST TO SILL, TOP PLATE OR GIRDER (TOE NAILED)
4-8d
4-10d
PER JOIST
ti
° - -
BLOCKING TO JOIST (TOE NAILED)
2-8d
2-10d
EACH END
U
L3/4"
BLOCKING TO SILL OR TOP PLATE (TOE NAILED)
3-16d
4-16d
EACH BLOCK
T$G PLYWOOD SUB -FLOOR GLUED
STEEL
BEAM
3/4" TtG PLYWOOD SUB -FLOOR GLUED
w
AND NAILED TYPICAL
WRAPPED w/5/S"
AND NAILED, TYPICAL
LEDGER STRIP TO BEAM OR GIRDER (FACE NAILED)
3-16d
4-16d
EACH JOIST
O
STEEL BEAM
TYPE
"X" FIRE
JOIST ON LEDGER TO BEAM (TOE NAILED)
3-8d
3-10d
PER JOIST
WRAPPED w/5/S"
„
2x12 FLOOR JOISTS 16 O.0
CODE
GWB
„
2x12 FLOOR JOISTS 16 O.0
BAND JOIST TO JOIST (END NAILED)
3-16d
4-16d
PER JOIST
TYPE "X" FIRE
BAND JOIST TO SILL OR TOP PLATE (TOE NAILED)
2-16D
3-16d
PER FOOT
CODE GWB
ROOF SHEATHING
5/g" TYPE "X" FIRE CODE GWB ENTIRE 5/8" TYPE "X" FIRE CODE GWB ENTIRE
GARAGE $ CEILING
GARAGE $ CEILING
WOOD STRUCTURAL PANELS
Y2" GYPSUM IF NO LIVING AREA ABOVE Y2" GYPSUM IF NO LIVING AREA ABOVE
J
Ix STRAPPING 16" O.G.
Ix STRAPPING 16" O.C.
RAFTERS OR TRUSSES SPACED UP TO 16" O.C.
8d
10d
6" EDGE/6" FIELD
RAFTERS OR TRUSSES SPACED OVER 16" O.C.
8d
10d
4" EDGE/6" FIELD
W
DROPPED STEEL BEAM
FLUSEEL BEAMdi
GABLE ENDWALL RAKE OR RAKE TRUSS w/o GABLE OVERHANG
8d
10d
6" EDGE/6" FIELD
0
_ 2"xB" NAILING SLEEPERS BOLTED TO
21'x8" NAILING SLEEPERS BOLTED TO
GABLE ENDWALL RAKE OR RAKE TRUSS w/ STRUCTURAL
8d
10d
6" EDGE/6" FIELD
�n
TOP AND BTI�I. FLANGES
TOP AND BTM. FLANGES
OUTLOOKERS
V
GABLE ENDWALL RAKE OR RAKE TRUSS w/ LOOKOUT BLOCKS
8d
10d
4" EDGE/4" FIELD
Z
BLOCKING
BLOCKING
"—
CEILING SHEATHING
OPTIONAL:
CCn n /`yIV1 n
CCG L BEAM
FLUSH STEEL
GYPSUM WALLBOARD
5d COOLERS
-
7" EDGE/10" FIELD
I--
W
m
WALL SHEATHING
_
STEEL BEAM TO
FLOOR CONNECTION
WOOD STRUCTURAL PANEL
lo
STUDS SPACED UP TO 24" O.C.
8d
10d
3" EDGE/12" FIELD
1 rr - r rr
SCALE 1 /2 — 1 -0
SCALE: 1 /8"
= 1 `-0"
Y2' AND 2V32' FIBERBOARD PANELS
8d
-
3" EDGE/6" FIELD
Y2' GYPSUM WALLBOARD
5d COOLERS
7" EDGE/10" FIELD
0
1 2 4
8
FLOOR SHEATHING
SHEET
WOOD STRUCTURAL PANELS
1" OR LESS
8d
10d
6" EDGE/12" FIELD
A OF 5
GREATER THAN 1"
10d
16d
6" EDGE/6" FIELD
.4
PROJECT: DATE:
21-900 9-14-2021