Loading...
HomeMy WebLinkAboutEngineer PlanV 20.5 x 0 I 7/8/21 AUGERED HOLE TO EL 18.5 NO WATER ENCOUNTERED LIPti O.0_____ _______________-_H '_�5_________._______________ P ADO �y1JE 25.8 x 0 SC ALE 1" = 20' 77.8 x PER AS BUILT 29.5 x 29.5 +- F lI 14" TEE WITH A ZAB EL FILTER 0 A100-8 USE EXISTING 1,000 GALLON H-10 SEPTIC TANK OcCK .#8 TOF ASSUMED 29.46 x 28.0 30.0 B.M. ASSUMED t8.8 x TOP WGHT CORNER , OF STEP. 2%5 x i b O -- PER AS BU T 0 P 29.4 � 28.7 0 79.5 x Q 7x •t 30.0 X SEPTIC SYSTEM PROFILE COVER TO WITHIN 6" OF FINISHED GRADE - COVER TO -FINISHED GRADE 27.7 I. .Ili 26.3 26.25 H-20 O-BOX 6" OF STONE OR COMPACTED BASE COVERS TO BE WITHIN 6" OF FINISH GRADE F.G. 29.5 + - MINIMUM 2" PEASTONE OR PIPE TO BE LEVEL - EOTEXTILE FABRIC FOR 2' OUT OF D-BOX TOP ®26.78 .M 9 1 25.95 (2) 500 GAL DRYWELL H-10 OTTOM ® 23.95 WITH 3/4" -1 1/2" OF DOUBLE WASHED STONE TO TOP OF PIPE I 10' X 20' X 2.4' 4.3' 5.45' BOTTOM OF 19.655 EL_ T.H. WATER 1 18.5 EL BOTTOM OF ENCOUNTERED NO WATER AUGER ENCOUNTERED HOLE WALK OUT CELLAR DEC K I SUNROOM c = DINING I KITCHEN i LIVING FIRST FLOOR ENTRY EXISTING FLOOR PLAN NOT TO SC ALE TEST HOLE LOG DATE: 7/7/21 TEST BY. MIKE O'LOUGHLIN WITNESS: PHILIP RENAUD PERC RATE: < 2 MIN TEST HOLE # 1 n" 29.65 EL FILL 8" 28.99 EL Ap LOAMY SAND 18" 10YR 4 2 28.15 EL BW LOAMY SAND 10YR 5/8 �" 26.33 EL C1 MEDIUM SAND 2.5Y 6/8 NO WATER 120"1 ENCOUNTERED 119.65 EL BOTTOM OF PERK 54" PRESOAK 13:0 MINS. < 2" GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00:1ITLE V. 3. THIS PLAN IS NOT TO BE USED FOR PROPERTY LINE DETERMINATION.' 4. DESIGNER TO INSPECT & CERTIFY OVER -DIG, IF OVER -DIG REQUIRED, AND COMPLETE FINAL INSPECTION BEFORE B AC KFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGI4ED FOR THE USE OF A GARBAGE DISPOSAL 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG, CONTACT SEPTIC SYSTEM DESIGNER AND THE HEALTH DEPARTMENT. 9. IF AN OVERDIG IS REQUIRED, REPLACE SOILS WITH CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) 5' AROUND S.A.S. 10. ALL 4" PIPE CONNECTIONS AT SEPTIC TANK AND D-BOX SHALL BE MORTARED IN PLACE. IF USING 18' PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE. DESIGN DATA MAXIMUM (2) BEDROOM DWELLING RESTRIC KTION D_AILY- FL_OVM: (2)'BEDROOM DESIGN X 110' GPD = 220 GPD -l1_1iv II-11 i1i. �. ., invr,u id v n 440 r�i0 JL USE: EXISTING 1,000 GALLON H-10 SEPTIC TANK DISTRIBUTION BOX: USE: DB-3 H-20 SOIL ABSORPTION SYSTEM: USE: (2) 500 GAL DRYWELLS H-10 WITH DOUBLE WASHED STONE SIDEWALL AREA: 60' X 2' = 120 SQFT BOTTOM AREA: 10' X 20' = 200 SQFT TOTAL AREA: 320 SQFT 320 SQFT X .74 = 236.8 GPD NOTES 1. PUMP OUT SEPTIC TANK, INSPECT INLET TEE TO CONFIRM IT IS PRESENT AND WORKING, AND INSTALL AN A100-8 ZABEL EFFLUENT FILTER ON OUTLET TEE WITH 18" COVER TO GRADE FOR MAINTENANCE AND CLEANING. 2. PUMP OUT AND REMO\4E EXISTING LEACHING PIT AND CONTAMINATED SOILS, TO BE INSPECTED BY DESIGN ENGINEER BEFORE ANY B AC KFILLING. Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to Irate and Local septic variances. Board of Hcaltb acview and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Dcparttncnt APPROVED Name ttX HEALTH ANENT APPROVAL DATE