Loading...
HomeMy WebLinkAbout8 Setucket Rd septic 1Q. !t KEY: 4 EXISTING CONTOUR: - — - PROPOSED CONTOUR: •--•--•---••• O EXISTING SPOT ELEVATION:25,5 -A PROPOSED SPOT ELEVATION: K,_ TEST HOLE: - UTILITY POL FENCE LINE HYDRANT: -6- RETAINING WALL: LOCUS jZ LT LOCATION 1 31 SF) ASSESSORS MAP: 143 PARCEL: 160 PLAN BOOK: 206, PAGE: 45 BED KITCHEN ROOM BATH DINING AREA IVING LIVING BED BED ROOM ROOM ROOM GARAGE 1st FLOOR Q MUD BATH ROOM 3 i FAMILY ROOM ROOM BASEMENT EXISTING FLOOR PLAN 7UN 14 2022 H LTH DEPT. O s9 O .� a d) Permit valid for REPAIR OF SEPTIC SYS OiNLV, due to State and 1 A of septic variances. Board of Health review and approval is required for any future additions/renirvations/alterations, to sewage facilities and/or structures/dwelling . Yarmouth N•eatth Department APPROVED me Date SEPTIC SYSTEM DESIGN L_4 ESTIMATE: BEDROOMS AT 110 GAL /�DAY440 GAL /DAY SEPTIC TANK: 440 GAL / DAY x 2 DAYS = 880 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5' x 4.8' x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (33.5' x 12 8' x 2' DEEP) SIDE AREA: (33.5' + 12.8') x 2 x 2 = 185 SF (0.74) = 137 GAL/DAY BOTTOM AREA: 33.5' x 12.8' = 429 SF (0.74) = 317 GAL/DAY CAPACITY = 464 GAL/DAY 86'/ ,r O 84 th-1 r ' f 12" oak \ + i� 16" pine /jOW&t i , 12" / 12"oak / \ pine ` 84 oak \ 82.1 86 1 f' 88 ' Q QaJ� l i t f� — --- -/--- - -- 93 5 84 �A BENCHMARK AT — ORANGE PAINT MARK ON WALL ELEVATION = 89.67 Sidewalk 0�G1 of PAVE SETUCKET ROAD SEPTIC SYSTEM SECTION /- COVERS WITHIN 6" / OF FINISHED GRADE OUTLET PIPE UNDER BASEMENT FLOOR EXISTING LEACH PIT (SEE NOTE 13) 90 TION 80.9 (EXISTING) ELEV. EV. 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN 90 D-BOX (6" STONE UNDER) (H-20) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: AMY VON HONE,R.S. DATE: 7-10-14 PERCOLATION RATE: < 2 MIN/IN '2" PEASTONE OR FILTER I WASHED STONE INSPECTION PORT C )' (1 71 4t 4r El "E33.5' x 3 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (33.5' x 1((2.8' x))2' DEEP) (TO BEHVENTED) THA 84.0 O/A HORIZONV LOAMY SAND 16" 10YR 4/2 82.7 B HORIZON LOAMY SAND 42" 10YR 5/8 5 D PERC AT 66" F8/4 775 AND171.0 NO GROUND WATER ENCOUNTERED NOTES: 1. V'ERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4, ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICAT14 5, PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL, T THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOi 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONN CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T, 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING LEACH PIT IS TO BE PUMPED AND REMOVED. 14. D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15.THIS PLAN REQUIRES THE APPROVAL OF A VARIANCE FROM TITLE 5, SECTION 15.221 (7), PROPOSED LEACH AREA TO BE MORE THAN Y BELOW GRADE, (VARIANCE OF 2'). Fj W rum W1 ;1 k THOMAS J. McL AT SITE PLAN LOCATION: 8 SETUCKET RD. YARMOUTHPORT M, PREPARED FOR: AMA PONS DATE: 7-11-14 SCALE: 1" = BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426 OR 508-364-9048