HomeMy WebLinkAbout185 Seaview Ave plan 18ELECTRICAL NOTES: 1. RECEPTACLES SHALL BE ARRANGED SO THAT AT NO POINT ALONG THE WALL SHALL THE DISTANCE TO A RECEPTACLE BE MORE THAN 6'-0' EXCEPT AT KITCHEN COUNTERTOPS WHERE RECEPTACLES SHALL BE PLACED NO MORE THAN 4' APART. 2. AT LEAST ONE RECEPTACLE SHALL BE INSTALLED IN HALLWAYS OF 10'-0" OR MORE IN LENGHT. 3. ANY WALL 2' IN LENGTH OR GREATER REQUIRES A RECEPTACLE (HABITABLE SPACE ONLY). 4. ALL COUNTERTOP RECEPTACLES AND SWITCHES TO MEASURE 44" TO BOTTOM OF BOX FROM FINISHED FLOOR (BOX HEIGHTS ARE APPROXIMATE). 5. WALL SWITCHES TO MEASURE 48" AND RECEPTACLES TO MEASURE 14 TO BOTTOM OF BOX FROM FINISHED FLOOR (BOX HEIGHTS ARE APPROXIMATE). 6. ALL RECEPTACLES TO BE GROUNDED TYPE. I 7, AN ARC —FAULT BREAKER IS REQUIRED FOR ALL 15 AMP AND 20 AMP CIRCUITS SUPPLYING OUTLETS LOCATED WITHIN A DWELLING UNIT, INCLUDING THE SMOKE ALARMS 8. A GFCI BREAKER OR LISTED TAMPER RESISTANT TYPE GFCI RECEPTACLE IS REQUIRED, BUT NOT LIMITED TO, ALL CIRCUITS SERVING ALL COUNTERTOP OUTLETS (2020 NEC 210.52) 9. A GFCI BREAKER OR LISTED TAMPER RESISTANT TYPE GFCI RECEPTACLE IS REQUIRED, BUT NOT LIMITED TO, ALL CIRCUITS SERVING ALL BATHROOM RECEPTACLES (2020 NEC 210.52) 10. A LISTED TAMPER RESISTANT TYPE EXTERIOR WEATHER—PROOF GFCI OUTLET IS REQUIRED TO BE LOCATED AT BOTH THE FRONT AND REAR OF ALL DWELLING UNITS (2020 NEC 210.52E). OUTLET MUST BE AT GRADE LEVEL. 11. PHOTO ELECTRIC SMOKE DETECTORS ARE REQUIRED AT THE FOLLOWING LOCATIONS: 11.1. IN EACH BEDROOM 11.2 SMOKE/CARBON MONOXIDE DETECTORS ARE INSTALLED AT THE FOLLOWING LOCATIONS: 11.2.1 OUTSIDE EACH SEPARATE BEDROOM IN THE IMMEDIATE VICINITY OF THE BEDROOM ON 1ST/2ND FLOOR 11.2.2 BASE OF THE STAIRS ON THE 1ST STORY 11.2.3 BASEMENT (ON —SITE) 11.2.4 N/A 11.3 HEAT DETECTORS ARE INSTALLED AT THE FOLLOWING EOC TION: 11.3.1 N/A` 'ROYAL STAMP PFS Corpo atio Northeast Regh APPROVED Michelle Eaker 04/08/20 2 Approval iIm ted to Factory Bulk rtioL 12. SMOKE DETECTORS TO BE DIRECTLY CONNECTED TO LIGI TING CI NO INTERVENING WALL SWITCH. Rd "OF MASS95 0 DAVID T. N t. fEENEY a No. 54747 t" �09FcISTV o��r L EN�fia 13. SMOKE DETECTORS MOUNTED ON CEILING OR WALL PER CODES & LISTING, NFPA 72, AND ARE TO BE INTERCONNECTED SO THAT IF ONE 1S ACTIVATED ALL WILL BE ACTIVATED, 14. CARBON MONOXIDE DETECTOR MOUNTED ON CEILING OR WALL PER CODES & LISTING. WHEN MORE THAN ONE CARBON MONOXIDE DETECTOR IS REQUIRED, THEY MUST BE INTERCONNECTED SO THAT IF ONE IS ACTIVATED ALL OTHERS WILL BE ACTIVATED, 15. COMBINATION SMOKE DETECTOR AND CARBON MONOXIDE DETECTORS WILL BE USED. 16, BATH FANS MUST BE VENTED TO EXTERIOR, IF NATURAL' VENTING IS NOT PROVIDED. O O r N C'4 U 0<c4 u Lip-' nod C) �O Cr 0 Cn g � R N�aw mIC�C�U-) Cn � z Q ¢ J CD z z 17. ADDITIONAL CIRCUITS MAY BE ADDED OR DELETED AS FLOOR PLAN OR � w z oaQCD SALES CONTRACT DICTATE, W C Q 18. CIRCUITS FOR LAUNDRY, INSTALLED IN PANEL BY MANUFACTURER w 19. RECESSED LIGHTING FIXTURES WHEN INSTALLED IN THE BUILDING ENVELOPE MUST BE TYPE IC RATED, WITH NO PENETRATIONS BETWEEN INSIDE FIXTURE AND THE CEILING CAVITY, AND GASKETED OR SEALED TO REVENT LEAKAGE; OR, TYPE IC OR NON —IC RATED INSTALLED INSIDE A SEAL BOX. 20. WATER HEATER IS IN BASEMENT (NOT PROVIDED BY ICON). 21. STEEL PROTECTORS SHALL BE USED TO PROTECT CABLES LESS THAN 1.25" FROM THE NEAREST EDGE IN ALL FRAMING MEMBERS, 22. NON—METALLIC SHEATED CABLE SHALE BE TYPE NM—B W/GROUND. 23. CONDUCTORS AND ELECTRICAL EQUIPMENT SHALL BE LABELED OR LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY, THE EQUIPMENT SHALL BE SUITABLE FOR LOCATION AND USE IN COMPLIANCE WITH ITS LABEL AND LISTING. 24, A 200 AMP PANEL BOX WILL BE USED. 25. PANEL BOX LOCATION IS IN THE REAR HALLWAY. 26, AN ENERGY EFFICIENCY CERTIFICATE SHALL BE POSTED ?N INSIDE OF PANEL BOX, SCALE 3/8' = f-0° SERIAL $/ ORXR # 0#10394 CV J 00 O \ CV O J J z w < a 0 _ YO �_ � � w z�Q'�(noml': ELECTRICAL NOTES