HomeMy WebLinkAbout185 Seaview Ave plan 18ELECTRICAL NOTES:
1. RECEPTACLES SHALL BE ARRANGED SO THAT AT NO POINT ALONG THE WALL
SHALL THE DISTANCE TO A RECEPTACLE BE MORE THAN 6'-0' EXCEPT AT
KITCHEN COUNTERTOPS WHERE RECEPTACLES SHALL BE PLACED NO MORE
THAN 4' APART.
2. AT LEAST ONE RECEPTACLE SHALL BE INSTALLED IN HALLWAYS OF 10'-0" OR
MORE IN LENGHT.
3. ANY WALL 2' IN LENGTH OR GREATER REQUIRES A RECEPTACLE (HABITABLE
SPACE ONLY).
4. ALL COUNTERTOP RECEPTACLES AND SWITCHES TO MEASURE 44" TO BOTTOM
OF BOX FROM FINISHED FLOOR (BOX HEIGHTS ARE APPROXIMATE).
5. WALL SWITCHES TO MEASURE 48" AND RECEPTACLES TO MEASURE 14 TO
BOTTOM OF BOX FROM FINISHED FLOOR (BOX HEIGHTS ARE APPROXIMATE).
6. ALL RECEPTACLES TO BE GROUNDED TYPE.
I
7, AN ARC —FAULT BREAKER IS REQUIRED FOR ALL 15 AMP AND 20 AMP
CIRCUITS SUPPLYING OUTLETS LOCATED WITHIN A DWELLING UNIT, INCLUDING
THE SMOKE ALARMS
8. A GFCI BREAKER OR
LISTED
TAMPER
RESISTANT TYPE GFCI
RECEPTACLE IS
REQUIRED, BUT NOT
LIMITED
TO, ALL
CIRCUITS SERVING ALL
COUNTERTOP
OUTLETS (2020 NEC
210.52)
9. A GFCI BREAKER OR
LISTED
TAMPER
RESISTANT TYPE GFCI
RECEPTACLE IS
REQUIRED, BUT NOT
LIMITED
TO, ALL
CIRCUITS SERVING ALL
BATHROOM
RECEPTACLES (2020
NEC 210.52)
10. A LISTED TAMPER RESISTANT TYPE EXTERIOR WEATHER—PROOF GFCI OUTLET
IS REQUIRED TO BE LOCATED AT BOTH THE FRONT AND REAR OF ALL
DWELLING UNITS (2020 NEC 210.52E). OUTLET MUST BE AT GRADE LEVEL.
11. PHOTO ELECTRIC SMOKE DETECTORS ARE REQUIRED AT THE FOLLOWING
LOCATIONS:
11.1. IN EACH BEDROOM
11.2 SMOKE/CARBON MONOXIDE DETECTORS ARE INSTALLED AT THE
FOLLOWING LOCATIONS:
11.2.1 OUTSIDE EACH SEPARATE BEDROOM IN THE IMMEDIATE VICINITY
OF THE BEDROOM ON 1ST/2ND FLOOR
11.2.2 BASE OF THE STAIRS ON THE 1ST STORY
11.2.3 BASEMENT (ON —SITE)
11.2.4 N/A
11.3 HEAT DETECTORS ARE INSTALLED AT THE FOLLOWING EOC TION:
11.3.1 N/A`
'ROYAL STAMP
PFS Corpo atio
Northeast Regh
APPROVED
Michelle Eaker
04/08/20 2
Approval iIm ted to
Factory Bulk rtioL
12. SMOKE DETECTORS TO BE DIRECTLY CONNECTED TO LIGI TING CI
NO INTERVENING WALL SWITCH.
Rd "OF MASS95
0
DAVID T. N t.
fEENEY
a
No. 54747
t"
�09FcISTV o��r
L EN�fia
13. SMOKE DETECTORS MOUNTED ON CEILING OR WALL PER CODES & LISTING,
NFPA 72, AND ARE TO BE INTERCONNECTED SO THAT IF ONE 1S ACTIVATED
ALL WILL BE ACTIVATED,
14. CARBON MONOXIDE DETECTOR MOUNTED ON CEILING OR WALL PER CODES &
LISTING. WHEN MORE THAN ONE CARBON MONOXIDE DETECTOR IS REQUIRED,
THEY MUST BE INTERCONNECTED SO THAT IF ONE IS ACTIVATED ALL OTHERS
WILL BE ACTIVATED,
15. COMBINATION SMOKE DETECTOR AND CARBON MONOXIDE DETECTORS WILL BE
USED.
16, BATH FANS MUST BE VENTED TO EXTERIOR, IF NATURAL' VENTING IS NOT
PROVIDED.
O
O
r N C'4 U
0<c4 u
Lip-' nod
C) �O
Cr 0
Cn g � R
N�aw
mIC�C�U-) Cn �
z Q ¢ J
CD z z
17. ADDITIONAL CIRCUITS MAY BE ADDED OR DELETED AS FLOOR PLAN OR � w z oaQCD
SALES CONTRACT DICTATE, W C
Q
18. CIRCUITS FOR LAUNDRY, INSTALLED IN PANEL BY MANUFACTURER
w
19. RECESSED LIGHTING FIXTURES WHEN INSTALLED IN THE BUILDING ENVELOPE
MUST BE TYPE IC RATED, WITH NO PENETRATIONS BETWEEN INSIDE FIXTURE
AND THE CEILING CAVITY, AND GASKETED OR SEALED TO REVENT LEAKAGE;
OR, TYPE IC OR NON —IC RATED INSTALLED INSIDE A SEAL BOX.
20. WATER HEATER IS IN BASEMENT (NOT PROVIDED BY ICON).
21. STEEL PROTECTORS SHALL BE USED TO PROTECT CABLES LESS THAN 1.25"
FROM THE NEAREST EDGE IN ALL FRAMING MEMBERS,
22. NON—METALLIC SHEATED CABLE SHALE BE TYPE NM—B W/GROUND.
23. CONDUCTORS AND ELECTRICAL EQUIPMENT SHALL BE LABELED OR LISTED BY
A NATIONALLY RECOGNIZED TESTING LABORATORY, THE EQUIPMENT SHALL BE
SUITABLE FOR LOCATION AND USE IN COMPLIANCE WITH ITS LABEL AND
LISTING.
24, A 200 AMP PANEL BOX WILL BE USED.
25. PANEL BOX LOCATION IS IN THE REAR HALLWAY.
26, AN ENERGY EFFICIENCY CERTIFICATE SHALL BE POSTED ?N INSIDE OF PANEL
BOX,
SCALE 3/8' = f-0°
SERIAL $/ ORXR #
0#10394
CV J
00 O \ CV
O
J
J z
w < a
0 _
YO
�_ � � w
z�Q'�(noml':
ELECTRICAL NOTES