HomeMy WebLinkAbout24 Easy St sprinkler plan 2ENT 1 T T'IUML r 1Rr— MLIARIV1 ADDRESSABLE LOOP WIRING. FIRE ALARM R E LAY DRAWING SYMBOL: FR] NOTES 1. THE DIAGRAM REPRESENTS A TYPICAL FIRE ALARM RELAY MODULE WIRING DIAGRAM. 2. PROVIDE FIRE ALARM RELAY MODULES FOR CONTROL OF THE FOLLOWING. NOTE THAT THIS LIST IS A REPRESENTATION OF THE TYPICAL DEVICES CONTROLLED. ALL OF THE ITEMS IN THE LIST MAY NOT BE APPLICABLE TO THE PROJECT, HOWEVER IT IS ALL INCLUSIVE. A. FIRE DOOR/SHUTTER (PROVIDE 1 PER DOOR/SHUTTER) B. DOOR HOLDER (PROVIDE 1 PER DOOR) C. BEACON (PROVIDE 1 PER BEACON) D. ELEVATOR RECALL (PROVIDE 4 PER ELEVATOR) E. SMOKE HATCH RELEASE (PROVIDE 1 PER HATCH) F. LTG TO FULL ON (PROVIDE 1 PER LTG OR DIMMER PNL) G. SECURITY SYSTEM INTERFACE (PROVIDE 2 PER SYSTEM) H. DOOR UNLOCK (PROVIDE 2 PER SECURITY PANEL) 3. COORDINATE VOLTAGE REQUIREMENTS OF CONTROLLED EQUIPMENT WITH THE RATINGS OF THE FIRE ALARM RELAY MODULE. TYPICAL FIRE ALARM RELAY MODULE REQUIREMENTS sCAEE: KT.& VIS? 1AL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 1. MINIMUM DISTANCE IN SLEEPING ROOMS IS 24" FROM CEILJNG TO TOP OF LENS FOR 11Ocd STROBES WITHIN 16' OF THE PILLOW. 2. 177cd STROBES, USED IN SLEEPING ROOMS CAN BE WITHIN THE 24' MNNMUM DISTANCE FROM THE CEILING. THE HIGHER INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. FOR CEILING HEIGHTS LESS THAN 86'. THE VISUAL LENS MOUNTING HEIGHT SHALL BE WITHIN 6" OF THE CEILING. 0 REF.80' MIN. (IBC) REF. 96' MAX. (IBC) ABOVE FINISHED FLOOR AUDIBLE/VISUAL & VISUAL ONLY APPLIANCES SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW FINISHED FLOOR SMOKE DETECTOR SHOULD NOT BE LOCATED A/C SUPPLY IN A DIRECT AIRFLOW NOT CLOSER THAN 3 OR RETURN FEET FROM AN AIR SUPPLY DIFFUSER DIFFUSER 3' (MIN) — ►� MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE SMOKE DETECTOR. FOR ACCESS MOUNT SMOKE DEFECTOR CLOSE TO BEAMS/WALLS SO THEY CAN BE REACHED FROM EXTENSION LADDER. CEILING CEILING MOUNTEDSMOKE/H( I NFPA 72 AUDIBLE APPLIANCE DEFECTORR 4' 6' MIN BELOW FINISHED DETECT cEluNc 12' AUDIBLE ONLY BEAM MIN. 5' AWAY (MAX.) 90' MIN. ABOVE FINISHED FLOOR (OTHER MOUNTING HEIGHTS SHALL BE PERMITTED FIR[ BY THE AHJ PROVIDING IT MEETS THE NEVER MOUNT DETECTOR SOUND LEVEL OUTPUT REQUIRED.) IN THIS AREA 96' MAX (NFPA, ADA) ABOVE FINISHED FLOOR TO TOP OF LENS 80" MIN. (ADA) 80' MIN. (NFPA) TO BOTTOM OF LENS MANUAL PULL STATION FIRE PHONE JACK 108.1 FIRE ALARM DFVICF MOUNTING HEIGHT REFERENCE (PER NFPA-72 SCAM* ICTa TO EXIT DOOR 5' (MAX.) Now DOOR WIDTH LESS 3' 0 5' MAGNETIC DOOR HOLDER 48' MAX. (ADA) 48' MAX. (NFPA, ADA) 42' MIN. (NFPA) MEASUREMENTS SHOWN ARE TO TOP OF PULL HANDLE 1 "ga A FdWm WALL MOUNTED SMOKE/HEAT DETECTOR FINISHED WALL FIRE ALARM NOTES: 1. FIRE ALARM RISER IS DIAGRAMMATIC AND DEPICT INTENT ONLY. REFER TO FLOOR PLANS FOR QUANTITY AND LOCATION OF DEVICES. 2. FIRE ALARM SYSTEM SHALL BE WIRED IN CLASS "A" FASHION. 3. SYSTEM WIRING SHALL BE INSTALLED IN ACCORDANCE WITH EQUIPMENT SUPPLIER'S APPROVED SHOP DRAWINGS AND WIRING DIAGRAMS. MINIMUM SIZE CONDUIT SHALL BE 3/4", U.N.O. 5. PROVIDE BATTERY LOAD CALCULATIONS FOR SUBMITTAL TO FIRE DEPARTMENT APPROVAL. 6. ALL STROBES WITHIN SAME ROOM OR FIELD OF VIEW MUST BY SYNCHRONIZED. 7. PROVIDE NOTIFICATION APPLIANCE POWER SUPPLIES/BOOSTERS TO ACCOMMODATE QUANTITY OF NOTIFICATION APPLIANCES SHOWN ON FLOOR PLANS WITH 25% ADDITIONAL SPARE CAPACITY - QUANTITY AS REQUIRED. QUIETO CONSULTING ENGINEERS DESIGN ENGINEERING SERVICES 14 WOOD ROAD SUITE 102 BRAINTREE, MA 02184 (508) 906-6370 • (781) 901-1775 Project D&D ELECTRIC 24 EASY STREET YARMOUTH, MA Stamp No. I Date I Revisions 1 09-19-221 ISSUE FOR PERMIT Drawing FIRE ALARM DETAILS Project Number Date SEPTEMBER 19, 2022 scale 3/16" = 1'-01' Sheet FA002