Loading...
HomeMy WebLinkAbout185 Seaview Ave plan 21RIDGE VENT & SHINGL CAPS FIELD INSTALLED PANELIZED ROOF SECTIONS BUILT BY ICON AND INSTALLED ON -SITE BY BUILDER PER SPECIFICATIONS ON TR3 & TR4 ARCH ASPHALT SHINGLES OVER DOUBLE LAYER OF 15# FELT PAPER (MIN) ON 7/16" W.S.P. OR BETTER REFERENCE PAGE TR3 & TR4 OF SET 12 FOR SPACING AND SPECIFICATIONS 7 FIXED SAVE OVERFII ALUM. DRIP EDGE 1/26 SUB, W/ ALUM. FASCIA OR 1x6 CEDAR FASCIA VENTED SOFFIT REFER TO RAFTER CALCULATIONS CO PRESSION R-51 (R-30 INSULATION ST IP (CONT.) w/VAPOR BARRIER + R-21 INSULATION ABOVE) 2X10 MIN SPF #2Y CEILING GIRDER 1/8" STRUCTURAL SHEATHING SIDING NOT o PROVIDED BY ICON LEGACY 00 2X4 SPF #2 @ 16" OC- GRADE TO SILL PER LOCAL REQUIREMENTS 3/4" T & G Q.S.B. 0 (GLUED & NAILED) TOP OF SILL PLATE 2X10 SPF:#2 @ 16" O.C. FLOOR JOIST a - w - R-30 INSULATION W/ VAPOR BARRIER (FIELD SUPPLIED AND INSTALLED) (4) 2X10 SPF#2 FLOOR GIRDER BOLTED WITH 1/2" THROUGH BOLTS @ 4' OC ON -SITE BY OTHERS 0 f 0 FOUNDATION WALL, FOOTINGS, DRAINAGE, ETC DESIGNED BY BUILDER PER LOCAL CODES CONCRETE FLOOR AND LOCAL SOIL CONDITIONS RIDGE BOARD Northeast Region APPROVED Michelle Baker 04/08/2022 Approval limited to Factory Built Portion oft' OF A.,gSs�c . DAVID o FEENEY y No. 54747 90,E QISTBP�G�.a`��Q S/ONAL EN -a :;r--- J SEE PAGES CV, RAFTER CALCS, SW1, SW2, TR3,1 TR4, SE4, AND FND FOR ON -SITE Cl4-5-22 D.Feeney 'NEON -SITE CONNECTION ('REQUIRED ALL ON-51TE CON ECTION5 ARE REQUIRED TO BE ERIFIED BY THE CON61P IO SUPERVI5OR PAGE TR4 IN FOR CONNECTIONS ARCH ASPHALT SHINGLES FASTEN PER R905.2.5 AND INSTALLED PER MANUFACTURERS HIGH WIND INSTALLATION INSTRUCTIONS AND PER SECTION R902 & R905,2.4.1 OF THE MA ONE- & TWO- FAMILY 12 DWELLING CODE, 9TH EDITION 7 *SEE PAGE TR4 IN SET FOR CONNECTIONS ICE SHIELD CONSISTING OF AT LEAST TWO LAYERS OF UNDERLAYMENT CEMENTED TOGETHER OR A WATERPROOF MEMBRANE SHALL EXTEND FROM THE EAVE'S EDGE TO A POINT 24" INSIDE THE EXTERIOR WALL LINE. 7/16" OSB SHEATHING REFER TO RAFTER CALCULATIONS 2X6 SPF STUD GRADE @ 16" O.C. 2xIO SPF #2 CEILING PERIMETER 2x2 LEDGER DBL 2X6 TOP PLATE, STUD GRADE OR JOIST HANGERS 5/8" DRYWALL R-21 HIGH DENSITY INSULATION W/VAPOR BARRIER DRYWALL MECHANICALLY FASTENED 7/16" OSB SHEATHING DBL ZX4 TOP PLATE, STUD GRADE PER SECTION R702.3.5 (ADHESIVE 2X6 SPF STUD GRADE ®16" O.C. �1/2" DRYWALL ONLY IS NOT PERMITTED PER EXTERIOR FINISH OVER AIR INFILTRATION R702.3.5.2) BARRIER OVER 7/16" AGENCY RATED SHTG PAPER ON EXTERIOR OF THE HOUSE "WATER RESISTIVE BARRIER PER THE MA ONE & TWO - FAMILY DWELLING CODE, 9TH ED TION 1/2" DRYWALL DBL. CAULKING BEAD ENTIRE PERIMETER OF EXT. WALLS DOUBLE PERIMETER BAND TOE NAILED TO SILL PLATE 2X4 SPF#2 BOTTOM PLATE WITH 16d NAILS 0 6" O.C. ON -SITE BY BUILDER, 2x6 SPF #2 BOTTOM PATE EXTERIOR SHEATHING FASTENED OVER SILL PLATE & MODULE SEAM WITH (2) ROWS OF 0.131"x2.5" NAILS 9 6" OC, 2X10 SPF #2 @ 16" O.C. FLOOR JOIST STAGGERED TO FLOOR BAND AND (1) ROW TO SILL @ 3" O.C. BY BUILDER. PLATE SEAL AS REO'D BY LOCAL OR STATE CODES, 2X6 MIN SP#2 PRESSURE TREATED SILL 2x2 LEDGER OR JOIST HANGERS T ANCHOR BOLT OR MIN APPROVED FASTENER 3/8"0,x9" MIN STEEL PLATE STEEL SUPPORT COLUMN (SIZED BY BUILDER) SEE FOUNDATION PLAN FOR SPACING REBAR MAY BE REQUIRED LOLLY COLUMN/FOOTING-/ (PENDING SOIL CONDITIONS) ALL VAPOR RETARDERS TO BE INSTALLED PER MANUFACTURES INSTRUCTIONS. ALL SITE INSTALLED PENETRATIONS INTO BUILDING ENVELOP SHALL BE SEALED AS REQUIRED BY CHAPTER 11 (ENERGY EFFICIENCY) OF THE MA ONE — + TWO — FAMILY DWELLING CODE, 9TH EDITION AND SHALL BE INSPECTED ON —SITE BY LOCAL BUILDING OFFICIAL SCALE 3/8' = SERIAL #/ ORDER / O#10394 9 O O r— ONO ,..,MN aamd'd O� v 17'O H.0 r/] kI w 4 : 0 U= a �U oa U► oa U v W� �o mlcn J J J C) J Z_ Z_ Un W Z Li L` Q L� 0- w w E)_ � co� 4 N ` W \ \ \ \ \ \ \ \ \ \ CO O— - N — p J ao�� = ID O,� W W > Q Q N �� iS � cj:� w J 0 d } � Q j W Cn DON w ii S ��Z�< w z � CL C � U') Z )=1 CD o 0 7/12 RANCH CROSS SECTION PAGE