HomeMy WebLinkAbout185 Seaview Ave plan 3GENERAL NOTES:
1 MODULE "A" IS 13'-9" IN WIDTH AND 43'-6" IN LENGTH, (SEE INDIVIDUAL FLOOR PLAN)
MODULE "B" IS 13'-9" IN WIDTH AND 34'-0" IN LENGTH, (SEE INDIVIDUAL FLOOR PLAN)
MODULE "C" IS 13'-9" IN WIDTH AND 19'-10" IN LENGTH, (SEE INDIVIDUAL FLOOR PLAN)
MODULE "D" IS 13'-9" IN WIDTH AND 19'-10" IN LENGTH, (SEE INDIVIDUAL FLOOR PLAN)
2, FOUR MODULES IN A DWELLING UNIT
3 HABITABLE ROOM SIZES SHALL BE A MINIMUM FLOOR AREA OF 70 SQ. FT. WITH A MINIMUM HORIZONTAL
DIMENSION OF 7 FEET PER R304 OF THE MA ONE- & TWO - FAMILY DWELLING CODE, 9TH EDITION
4. SPACES MEETING MIN. HABITABLE SPACE REQUIREMENTS SHALL COMPLY WITH HABITABLE SPACE REQUIREMENTS NOT LESS
THAN 8% OF FLOOR AREA OF SUCH ROOMS, MINIMUM OPENABLE AREA TO OUTDOORS SHALL BE 4% OF FLOOR AREA VENTED
PER R303 OF THE MA ONE- & TWO - FAMILY DWELLING CODE, 9TH EDITION
5. A PRIMARY AND SECONDARY EGRESS DOOR SHALL BE PROVIDED FOR EACH DWELLING AND SHALL BE AS REMOTE AS
POSSIBLE FROM EACH OTHER, THE PRIMARY EGRESS SHALL BE SIDE HINGED, AND PROVIDED A MIN. CLEAR WIDTH OF
32" MEASURED FROM THE FACE OF THE DOOR ® 90° TO THE STOP. THE SECONDARY EGRESS DOOR SHALL BE SIDE HINGED
OR SLIDING AND PROVIDED A MIN, CLEAR OPENING WIDTH OF 32". THE CLEAR OPENING HEIGHT OF EGRESS DOORS SHALL
PROVIDED A MIN. CLEAR OPENING OF 78" MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP PER
SECTION R311.2 OF THE MA ONE- & TWO - FAMILY DWELLING CODE, _9TH EDITION.
6, EXTERIOR DOORS SHALL NOT SWING OVER STAIRS WHEN A LANDING IS NOT AVAILABLE PER R311.3.1 OF THE MA ONE - &
TWO - FAMILY DWELLING CODE, 9TH EDITION. EXCEPTION: STORM -SCREEN DOORS ARE PERMITTED TO SWING OVER THE STEPS
PER R311.3,3 OF THE MA ONE- & TWO - FAMILY DWELLING CODE, 9TH EDITION.
7. ALL NOTES PERTAINING TO "IN FIELD OR ON SITE' ARE BUILDER/CONTRACTOR RESPONSIBILITIES.
8. KITCHEN AND/OR BATH CABINETS AND FIXTURES MAY BE SHIPPED LOOSE AND INSTALLED ON SITE AFTER PAINTING AND/OR
FASTENING IS COMPLETED. KITCHEN AND/OR BATH CABINETS ARE TO BE INSTALLED PER APPROVED PRINTS, INCLUDING
ELECTRICAL & PLUMBING.
9. KITCHEN AND/OR BATH CABINETS AND FIXTURES MAY BE FURNISHED AND INSTALLED ON SITE BY BUILDER
10, A PHOTOELECTRIC SMOKE DETECTOR REQUIRED EVERY 1,000 SO. FEET AND SHALL BE INSTALLED GREATER THAN 3 FEET FROM
ANY BATHROOM DOOR THAT CONTAINS A BATHTUB OR SHOWER AND LOACTED IN EACH SLEEPING ROOM, OUTSIDE IN THE
IMMEDIATE VICINITY OF THE BEDROOMS, ON EACH ADDITIONAL STORY OF THE DWELLING INCLUDING BASEMENTS AND HABITABLE
ATTICS, AND NEAR ALL STAIRS PER R314.3 OF THE MA ONE- & TWO - FAMILY DWELLING CODE, 9TH EDITION, A CARBON
MONOXIDE DETECTOR IS REQUIRED OUTSIDE OF EACH SLEEPING AREA WITHIN 10 FEET OF THE BEDROOM, WHERE FUEL BURNING
APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BATHROOM (DETECTOR TO BE INSTALLED IN BEDROOM), AND
ONE ON EACH STORY OF A DWELLING UNIT, INCLUDING BASEMENTS AND CELLARS BUT NOT IN CRAWL SPACE OR UNHABITABLE
ATTICS PER R315.3 OF THE MA ONE & TWO - FAMILY DWELLING CODE, 9TH EDITION.
11. WASHING MACHINE AND CLOTHES DRYER SUPPLIED AND INSTALLED ON SITE BY BUILDER IN ACCORDANCE WITH MANUFACTURER
INSTRUCTIONS, AND ALL STATE AND LOCAL CODES (SEE FRI FOR SPECIAL INSTRUCTION, IF REQUIRED).
2. WATER HEATERS EQUIPMENT IN ENCLOSED SPACES SHALL BE INSTALLED IN COMPLIANCE WITH THE LISTED MANUFACTURER
INSTRUCTIONS, AND ALL STATE AND LOCAL CODES (SEE FP1 FOR SPECIAL INSTRUCTION, IF REQUIRED).
13. HOLES, OPENINGS, AND ACCESS PROVISIONS FOR COMPLETION OR INSTALLATION OF EQUIPMENT MAY BE COMPLETED IN
FIELD, IF DONE IN SUCH A MANNER AS NOT TO AFFECT THE INTEGRITY OF THE STRUCTURE.
14. ALL PIPING (R403.4) AND DUCTWORK (R403.3.1) IN UNHEATED SPACES IS TO BE INSULATED IN COMPLIANCE
WITH 2O18 ENERGY CONSERVATION CONSTRUCTION AND THE NATIONAL ELECTRICAL CODE, 2020 EDITION.
15. COMBUSTION AIR SUPPLIED FROM EXTERIOR PER G2407.6 OF THE MA ONE- & TWO - FAMILY DWELLING CODE, 9TH EDITION,
16. ROOF COVERINGS SHALL BE LISTED AS CLASS 'C' OR BETTER PER SECTION R902.1 OF THE MA ONE- & TWO - FAMILY
DWELLING CODE, 9TH EDITION.
17. ATTIC VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE SPACE VENTILATED, EXCEPTION: THE AREA MAY BE
REDUCED TO 1/300 WHERE AT LEAST 40% AND NO MORE THAN 50% OF THE VENTILATING AREA IS PROVIDED BY VENTILATORS
LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN
3 FEET (914 mm) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE
REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS PER R806.2 OF THE MA ONE- & TWO - FAMILY DWELLING CODE,
9TH EDITION.
18. RESERVED
Michelle
Approval limited to
,actory Built Fbrtiol
`N OF M4SS9
cy
DAVID T. m
o FEENEY
N0.54747 y
�O,a F4/STEP�6��4`�Q
S�ONAL EN
19, HEAT DETECTOR IS REQUIRED IN ANY GARAGE ATTACHED TO OR UNDER THE DWELLING (NOT REQUIRE IN DETACHED GARAGE) PER
R314.8 OF THE MA ON17- & TWO - FAMILY DWELLING CODE, 9TH EDITION AND IS TO BE INSTALLED 0 A FLAT FINISHED CEILING,
NEAR THE CENTER OF THE GARAGE PER R314.8.1 OF THE MA ONE- & TWO -FAMILY DWELLING CODE, 9TH EDITION.
20.
21
22.
ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATION OPENINGS PROTECTED AGAINST THE
ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16" (1.6mm) MINIMUM AND 1/4" (6.4
mm) MAXIMUM. VENTILATION OPENINGS HAVIND A LEAST DIMENSION LARGER THAN 1/4" (6.4mm) SHALL BE PROVIDED WITH CORROSION
RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16"
(1.6mm) MINIMUM AND 1/4" (6.4mm) MAXIMUM PER R806 OF THE MA ONE - & TWO - FAMILY DWELLING CODE, 9TH EDITION
GUTTERS, LEADERS, AND SPLASH BLOCKS FURNISHED AND INSTALLED BY BUILDER ON SITE.
APPROVED WATER RESISTIVE BARRIER REQUIRED UNDER ALL SIDING TYPES PER SECTION R703.2 OF THE MA ONE - & TWO - FAMILY
DWELLING CODE, 9TH EDITION. FIRST LAYER OF APPROVED BARRIER, FREE FROM HOLES, SHALL BE INSTALLED HORIZONTALLY WITH THE
UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THEN 2" (51mm). WHERE JOINTS OCCUR, F LT SHALL BE LAPPED NOT LESS
THAN 6" (152mm). THE APPROVED BARRIER SHALL BE CONTINUOUS TO THE TOP OF WALLS AND TERM NATED AT PENETRATIONS AND
BUILDING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOP A DESCRIBED IN SECTION
R703.1.1 OF THE MA ONE - & TWO - FAMILY DWELLING CODE, 9TH EDITION.
23. SAFETY GLAZING (TEMPERED GLASS) REQUIRED IN THE FOLLOWING LOCATIONS PER R308.4 OF THE MA
DWELLING CODE, 9TH EDITION:
ONE - & TWO - FAMILY
23.A. GLAZING IN FIXED AND OPERABLE PANELS OF SWINGING, SLIDING, AND BIFOLD DOORS.
23.B. GLAZING IN STORM DOORS
23.C. GLAZING IN WALLS, ENCLOSURES, OR FENCES CONTAINING OR FACING HOT TUBS, SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS,
BATHTUBS, SHOWERS, AND INDOOR OR OUTDOOR POOLS UNLESS THE BOTTOM EDGE OF THE GLAZING IS MORE THAN 60" (1524mm)
MEASURED VERTICALLY ABOVE THE STANDING OR WALKING SURFACE OR THE GLAZING IS MORE THAN 60" (1524mm), MEASURED
HORIZONTALLY AND IN A STRAIGHT LINE FROM THE WATER'S EDGE,
231). GLAZING WITHIN A 24" RADIUS OF A DOOR PANEL EDGE AND LESS THAN 60" (1524mm) ABOVE THE WALKING SURFACE (EXCEPT
WHEN ADJACENT TO A FIXED PANEL OF PATIO DOOR OR DOOR IS TO A CLOSET LESS THAN 3' (914mm) IN DEPTH).
23.E. GLAZING ADJACENT TO STAIRS AND RAMPS WITHIN 36" (914mm) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF
STAIRWAYS, LANDING BETWEEN FLIGHTS OF STAIRS, AND RAMPS EXCEPT WHERE A RAIL IS INSTALLED ON THE ACCESSIBLE SIDE 34"-
38" (864-965mm) & CAN WITHSTAND A FORCE OF 50 LBS/F (730 N/m) OR IS MEASURED 36" (914mm) OR GREATER
HORIZONTALLY FROM THE WALKING SURFACE,
23.F. GLAZING ADJACENT TO TOP & BOTTOM STAIR LANDING WITHIN 36" (914mm) ABOVE THE LANDING AN WITHIN A 60" (1524mm)
HORIZONTAL ARC LESS THAN 180 DEGREES FROM THE BOTTOM TREAD NOSING.
23.G. GLAZING IN SKYLIGHTS
23.H. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL (MUST MEET ALL THE FOLLOWIT:
23.H.1. INDIVIDUAL PANE GREATER THEN 9 SQ.FT (0.836 SO. M).
23.H.2. BOTTOM EDGE OF GLAZING LESS THEN 18" (457mm) ABOVE FLOOR
23.H.3. TOP EDGE GREATER THEN 36" (914mm) ABOVE FLOOR.
23.H.4. ONE OR MORE WALKING SURFACES WITHIN 36" (914mm) HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING.
24. ANY STRUCTURAL GLUED LAMINATED TIMBERS THAT ARE EXPOSED MUST BE PRESSURE TREATED PER R317.1.5 OF THE MA ONE -
& TWO - FAMILY DWELLING CODE, 9TH EDITION.
25. WHERE LEDGERS ARE REQUIRED, A MIN. 2X2 LEDGER MUST BE USED, OR A JOIST HANGER IN PLACE 01 LEDGER.
26. SPACING OF INTERMEDIATE GUARDRAILS AT STAIRWAYS SHALL BE SUCH THAT A 4" (102mm) IN DIAME ER SPHERE PASS THROUGH
PER R312.1.3 OF THE MA ONE - & TWO - FAMILY DWELLING CODE, 9TH EDITION.
27. ANY DECK, PORCH, RAMP, OR STEPS, REACHING A HEIGHT GREATER THAN 30" (762mm) MEASURED VERTICALLY TO THE FLOOR OR
GRADE BELOW AT ANY POINT WITHIN 36" (914mm) HORIZONTALLY TO THE EDGE OF THE OPEN SIDE REQUIRE GUARDS PER R312 OF
THE MA ONE - & TWO - FAMILY DWELLING CODE, 9TH EDITION,
28, CAULKING AND SEALANTS IN THE EXTERIOR ENVELOPE MUST BE IN COMPLIANCE WITH THE 2015 ENERG CONSERVATION CONSTRUCTION
CODE w1MA AMENDMENTS. ALL JOINTS, CONNECTIONS, AND PENETRATIONS BETWEEN CONDITIONED SPACE AND UNCONDITION OR OUTSIDE
SPACE MUST BE SEALED.
29. ONLY CEMENT, FIBER -CEMENT AND GLASS MAT GYPSUM BACKERS SHALL BE USED AS BACKER ON TILED TUB AND SHOWER WALL PER
R702.4.2 OF THE MA ONE - & TWO - FAMILY DWELLING CODE, 9TH EDITION, NO GREEN BOARD GYPSUM BOARD SHALL BE PERMITTED,
30, MIN, FLAME SPREAD CLASSIFICATION OF ALL FINISH MATERIALS SHALL HAVE A RATING OF LESS THAN �00 PER R302.9.1 OF THE MA
ONE - & TWO - FAMILY DWELLING CODE, 9TH EDITION.