HomeMy WebLinkAbout185 Seaview Ave plan 41WINDOWS + DOORS REQUIRED TO MEET A DP +/-40 RATING (ZONE 5 - EDGE) WINDOWS -I- DOORS REQUIRED TO MEET A DP +/-31 RATING (ZONE 4 - FIELD) * - EGRESS WINDOW (MEET OR EXCEED CLEAR OPENING AREA OF 5.7 SO. FT. OR O.53 M2, CLEAR OPENING WIDTH OF 20' (508 MM) AND CLEAR OPENING HEIGHT OF 24' (610 MM) PER R310.2.1 OF THE 780CMR - 9TH EDITION) WINDOW TESTING AND LABELING IN COMPLIANCE WITH AAMA/WDMA/CSA 101/I.S.2/A440 PER R609.3 OF 2015 IRC LOCATED ON EACH WINDOW WITH A STICKER/LABEL WINDOW ANCHORING TO BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND MEET THE REQUIRMENTS SET FORTH IN R609.7 OF THE 2015 IRC WINDOW MULLIONS IN ACCORDANCE WITH AAMA 450 PER R609.8 OF 2015 IRC LOCATED ON EACH WINDOW WITH A STICKER/LABEL PFS Corporation Northeast Region APPROVED Michelle Baker 04/08/2022 Approval limited to Factory Built Portion µ OF M4,p a DAVIT) T. m o FEENEY No.54747 $ 9s eo c OFF. QTS7EP GN�� SS/ONAL EN '7;T= 4-4-22 D.Feeney DOOR AND WINDOW SCHEDULE WINDOWS CLEAR OPENING CLEAR OPENING DESCRIPTION ROUGH OPENING AREA LIGHT WIDTH EACH HEIGHT EACH VENT U FACTOR SHGC QTY TOTAL AREA 7D 7700 SERIES DOUBLE HUNG 2446DH-2 59 3/4" X 57 1/2" 23,86 16.8 25.562 24.562 8.80 0.29 0.39 2 47.72 *7D 7700 SERIES DOUBLE HUNG 3046DH 38 1/8" X 57 1/2" 15.22 11.2 33.562 24.562 5.70 0.29 0.39 8 121.76 +M 7D 7700 SERIES DOUBLE HUNG 3046DH-2 75 3/4" X 57 1/2" 30.25 22.4 33.562 24.562 11.40 0.29 0.39 2 60.50 TOTAL AREA: 229.98 EXTERIOR DOORS CLEAR OPENING CLEAR OPENING DESCRIPTION ROUGH OPENING AREA LIGHT WIDTH (EACH} HEIGHT (EACH) VENT U-FACTOR SHGC QTY TOTAL AREA THERMA-TRU (SINGLE DOOR) 2868 (<50% GLASS) 34 3/8" X 82 1/2" 19.69 5.5 29.313 79.250 16.14 0.25 0.17 1 19.69 THERMA-TRU (SINGLE DOOR) 3068 (<50% GLASS) 38 3/8" X 82 1/2" 21.99 5.5 33,313 79.250 18.34 0.25 0.17 1 21.99 _ TOTAL AREA: 41.68 THIS SCHEDULE IS FOR SHIPLOOSE WINDOWS THAT WILL BE PROVIDED BY ICON LEGACY AND WILL NEED TO BE INSTALLED TO MANUFACTURES INSTRUCTION BY OTHERS AND INSPECTED BY LOCAL BUILDING OFFICIAL SHIPLOOSE WINDOWS AND DOORS NOT INSTALLED BY ICON LEGACY DOOR AND WINDOW SCHEDULE WINDOWS DESCRIPTION ROUGH OPENING CLEAR OPENING CLEAR OPENING AREA LIGHT WIDTH (EACH) HEIGHT (EACH) VENT J-FACTOR SHGC QTY TOTAL AREA 7D 7700 SERIES AWNING 3018AW 36 1/2" X 21" 5.32 2.9 0.000 0.000 1.50 0.27 0.33 1 5.32 TOTAL AREA: 5.32 NNA. WINDOW FLASHING: WATER RESISTIVE BARRIER: t. INSTALL SELF -STICKING RUBBERIZED FLASHING OVER THE SUB -FRAME AT THE SILL OF WINDOW 1. INSTALL WATER RESISTIVE BARRIER HORIZONTALLY IN A SHINGLE LIKE OVERLAPPING SUCCEEDING COURSE BY A MIN. OF f. p INSTALL WINDOW PER MANUFACTURERS INSTALLATION INSTRUCTIONSFASHION, 2. CUT WATER RESISDVE BARRIER AT WINDOW / DOOR R.O. AND WRAP 3• RUN A STRIP OF SELF -STICKING RUBBERIZED FLASHING ON TOP OF THE NAILING FLANGE DOWN R.O. WITH WATER RESISTIVE BARRIER. THE SIDES OF THE WINDOW AND OVERLAPPING THE SILL FLASHING. 3. CUT AT A 45' ANGLE TEMP. TACK THIS FLAP UP OUT OF THE WAY 4. INSTALL TOP STRIP OF SELF -STICKING RUBBERIZED FLASHING ON TOP OF THE NAILING FIANCE ACROSS THE TOP OF THE WINDOW OVERLAPPING THE SIDE FLASHING. 5. LAP THE TOP STRIP OF WATER RESISTIVE BARRIER DOWN OVER THE TOP STRIP OF RUBBERIZED FLASHING AND THE VERTICAL LEG OF THE METAL CAP FLASHING. TAPE THE 45' SEAMS, m � � - En � ED J J J z Q C) w z z in _I Q o w z_ Of w w N N Q Ln N N 00 O \ N - - O C0 N O NOTE SIDE & TOP SELF -STICK RUBBERIZED FLASHING STARTS IN DOOR NAILING FLANGE, THEN GOES Lil OUT OVER SUB -FRAME, THEN WRAPS BNX TO Q = WALL SHEATHING PLANE AND EXTENDS DDT OLl J (Jj UNDER SIDING (THE SILL FLASHING STAR - UNOER THE NAILING FLANGE, THEN IS IN TALLED W Q 3Ln w z THE SINE THE SIDE &TOP FLASHING) N Z-5 3 3 C� �] J O Z w, CONTOUR LT FLASHING LW } w � < G7 W w CG _J d DOOR FLASHING• , < Q LL) 1. INSTALL SELF-STCKING RUBBERIZED FLASHING OVER THE SUB -FRAME AT THE BOTTOM SILL OF o � � V) � Cr DOOR z C w LC7 D HQ_ QO 2. INSTALL DOOR PER MANUFACTURERS INSTALLATION INSTRUCTIONS Ia-I - o } d , Q a Q z 0- E5 V) 0 M T- c 3. RUN A STRIP OF SELr-STICKING RUBBERIZED FLASHING ON TOP OF THE NAILING FLAN E DOWN THE SOB OF THE DOOR AND OVERLAPPING THE BOTTOM SILL FLASHING. 4, INSTALL TOP STRIP OF SELF -STICKING RUBBERIZED FLASHING ON TOP OF THE NAILING FLANGE DOOR & WINDOW SCHEDULE ACROSS THE TOP OF THE WINDOWOVERLAPPING THE SIDE FLASHING. 5. INSTALL METAL CAP FLASHING OVER THE TOP FINISH TRIM BOARD SCALE:1/4' - T-0° S. LAP THE TOP STRIP OF WATER RESISTIVE BARRIER DOWN OVER THE TOP STRIP OF RU BERIZEO RERIAE p/ on" g IA g: FLASHING AND THE VERTICAL LEG OF THE METAL CAP FLASHING. TAPE TFIE 45' SEAM . 1 9 7, THRESHOLD FLASHING I °�"��