HomeMy WebLinkAbout103 River St plan 1GENERAL REQUIREMENTS 1. CONTRACTOR TO REVIEW ALL DRAWINGS AND DIMENSIONS AND BRING ANY DISCEPENCY TO THE ATTENTION OF THE ARCHITECT. 2. NOTIFY ARCHITECT PRIOR TO PLACING CONCRETE & COMPLETION OF STRUCTURAL FRAME. 3. CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION WAYS AND MEANS. 4. COORDINATE WITH STRUCTURAL DRAWINGS AND SPECIFICATIONS. 5. COORDINATE LAYOUTS WITH INTERIOR DESIGNER PRIOR TO ROUGH PLUMBING. FOUNDATION 1. ALLOWABLE SOIL STRESS, 2000 LBS / SF 2. ALL FOOTINGS TO BE PLACED ON UNFROZEN, UNDISTURBED OR COMPACTED SOIL. 3. ALL FOOTINGS TO BE 4' BELOW GRADE MIN. 4. DAMPPROOF ALL EXTERIOR CONCRETE IN CONTACT WITH SOIL 5. PROTECT FOOTINGS AGAINST FROST 103 River Street, South Yarmouth MA UNTIL BACKFILLED 6. PROVIDE PERIMETER PERFORATED DRAIN. 7. PROVIDE VAPOR BARRIER UNDER ALL SLABS & PERIMETER UNDERSLAB PERFORATED DRAIN. 8. EXTERIOR FOOTINGS MINIMUM 4' BELOW GRADE. INTERIOR FOOTINGS JUST UNDER SLAB. CONCRETE 1. COMPRESSIVE STRENGTH OF CONCRETE TO BE 3000 PSI AT 28 DAYS 2. SLABS ON GRADE TO BE PLACED IN 1,200 SF PANELS MAX. ON MIN. 4" COMPACTED CRUSHED STONE AND 10 MIL VAPOR BARRIER & 2" RIGID TYPE IX EPS INSULATION. 3. SLABS TO BE REINFORCED WITH 6X6 WWF. 4. CONTROL JOINTS TO BE CUT OR TROWELD 1/4" DEEP AT 20'X20' MIN. SPACING. 5. MINIMUM CONCRETE COVER FOR REBAR IN AREAS IN CONTACT WITH GROUND TO BE 3" MIN. 6. MINIMUM CONCRETE COVER FOR OTHER sat. view AREAS TO BE 2" MIN. 7. SLOPE GARAGE FLOOR 1/4" /FT TO DOOR. STRUCTURAL STEEL CONSTRUCTION 1. ALL STEEL TO BE A36, PRIMED 2. BASEMENT COLUMNS TO BE 4X4X1/4" TUBE OR PIPE WITH 5/8" X 9"X 4" TOP PLATE AND 6"X9"X5/8" BOTTOM PLATE, LAG BOLTED TO BEAMS WITH 4 5/8" LAG BOLTS OR LALLY COLUMNS W/ HEAVY GRADE STEEL JACKET. 5/8" GWB WRAP MIN. FOR FIRE PROTECTION OF HOLLOW COLUMNS. STRUCTURAL WOOD CONSTRUCTION 1. ALL FRAMING LUMBER KD OR ENGINEERED. 2. NEW FRAMING TO HAVE THE FOLLOWING MINIMUM ALLOWABLE BENDING STRESS (Fb), SHEAR (Fv) AND MODULUS OF ELASTICITY (E) 2" WIDE JOIST FB = 1,200 MIN.) E _ 1,500,000, FV = 150 PSI 3. STUDS - Fb = 1,000 PSI, E = 1,200,000, FV = E=1,200,000 PSI 4. LAMINATED VENEER LUMBER - BENDING Fb = 2,800 PSI, E = 2,000,000 PSI, SHEAR = 290 PSI. 5. SILLS TO BE 2 - 2X6 PT WITH 5/8" X 1' ANCHORS BOLTS @ 4' O.C. 6. BEARING PARTITIONS SHALL BE BRIDGED @ MID HEIGHT. 7. FLOOR SPANS > 10' SHALL BE BRIDGED. 8. BUILT UP WOOD BEAMS SHALL BE BOLTED WITH TIMBER LOCK 3/16" BOLTS AT 16" O.C. STAGGARD. 9. LEDGERS SHALL BE LAGED TO STUDS OR JOIST BAND @ 32" O.C. MIN. WITH LEGER LOCK 3/8" LAGS. SPANS GREATER THAN 8' TO BE 2 - 3/8" LAGS @ 32" O.C. 10. NO JOIST SHALL BE NOTCHED AT TOP OR BOTTOM. 11. PROVIDE DOUBLE JOIST UNDER ALL NON LOAD BEARING PARTITIONS PARALLEL TO FLOOR FRAMING. 12 PROVIDE SOLID BLOCKING WHERE JOIST ENDS ARE UNRESTRAINED FROM ROTATION. 13. MINIMUM BEARING FOR ALL JOIST OR RAFTERS TO BE 3" 75 PSI Existing condition pre approvals 14. MINIMUM BEARING FOR ALL BEAMS TO BE 3.511 15. LINTELS TO BEAR ON MINIMUM OF 2 JACK STUDS. 16. PLYWOOD OR OSB FOR SUBFLOOR TO BE 3/4" T&G GLUED AND GUN NAILED 8" X16". 17. COLUMNS TO BEAR ON SOLID WOOD BLOCKING. METAL CONNECT OR LAG TOPS & BOTTOMS WITH FOUR - 3/8" LAGS 2" TARGET EMBEDMENT FOR CONTINUOUS RESISTANCE TO UPLIFT. 18. ALL RAFTERS TO BEAM & RAFTER TO PLATE CONNECTIONS TO BE METAL CONNECTED W/ SIMPSON H2.5 HURRICANE CLIPS. 19. RESOLVE LOADS ON CLOUMNS TO FOUNDATION OR BEAM BELOW. SOLID BLOCK ALL CAVITIES FOR CONTINUOUS BEARING. 20. ALL JOIST HANGERS TO BE SIZED TO REACTIONS OF BEAMS OR JOIST. 21. PRESSURE TREATED WOOD TO BE USED AT ALL WOOD TO CONCRETE CONTACT. 22. PROVIDE SHOP DRAWINGS FROM MANUFACTURER OF WOOD FRAME IF USED Image 1 Project: DATE: 103 River South Yarmouth MA Feb.-21-23 Owner: The Hearn's Architect: Sangiolo Associates Architects www.sangioloassociates.com ItNkEDAP �� ,�SA- 617 272 5402 No, 74" � YAW t€A, Structural: Drawing: A0 COVER & SPECIFICATIONS PERMIT DRAWINGS AO - COVER & SPECIFICATIONS Al - AXON & ROOF PLAN A2- FOUNDATION PLAN A3 - FOUNDATION WALLS A4 - FIRST FLOOR PLAN A5 - SECOND FLOOR PLAN A6 - ELEVATIONS A7 - ELEVATIONS A8 - SECTIONS A9 SECTIONS S1 - FIRST FLOOR FRAMING S2 - SECOND FLOOR FRAMING S3 - ROOF FRAMING t _ - .7. J REV AW HE AN1 COMr�,.:... DATE: A CERTI;'I-') AS BUILT IS REQUIRED L Oill i iNAL INSPECTION 0 R 03 H F 1 LT,y 0ep r ,, -> -2® t -V)S3kV