Loading...
HomeMy WebLinkAbout34 glenwood st plan 1a YAS 2- - �-S4 PROPOSED EXISTING PROP. CUSTOM CUPOLA �,A < COPPER Roof 4"(+1-) BASE ILAIR COPPER CAP STONE VENEER ASPHALT ROOF SHINGLES 12 9.25 001 CEILING HT. CEDAR SHINGLE SIDING PROPOSED NEW ASPHALT SHINGLE ROOF MATCH EXIST. DESIGN 4� COURSING z (SEE DETAIL) :J 5TAINLE55 STEEL CABLE RAIL SYSTEM 4X6 POSTS, BOXED OUT TO 12" WIDE, W.C. c MATCHSHINGLES EXIST. DESIGN *(TYPICAL) COURSING I X4'5 @ (SEE DETAIL) 161, O.C. + �INE Of EX15T. (3) 2X85 WALL/ ROOF L GUTTERS DOWNSPOUTS PROPOSED PORCH EXTENSION I EXIST. PORCH ROOF SECOND FLR TOP PLATE TOP PLATE 01 T H I ALIGN TO EXIST. HDR EHI �l I I I I I L A A --T 0 -7- 4X4 BRACKETS -011 EXIST. DOOR -1 PROP. ALUMINUM SCREEN UU, Ln 11 11 FRAMED INSERTS + EXISTINGHOUSE Lis - EXISTING FIRST f LR ------ EXISTING f I R5T f LK H PROF. PORCH FLOOR r% F-; 91 W. X &H, O.H. DOOR PROP. POR6H�ADDITION (LVL HEADER CORi JER TO CORNER) c? ICRtAWL I I SPACE S2 si — — — — — — — — — — — — — — — — — — L,--- -- J 6 6 -- — — — — — — — — — — — — — — — — — -- L 5 1 EXIST. FULL BASEMENT 1 8 6 j 1 Fi- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- j PROPOSED FRONT ELEVATION CEDAR SHINGLE 511 MATCH EXIST. DE51 (SEE DETAIL) EXPAND EXISTING FRONT PORCH r-mut-. l)k-,mccINcL-) rum�,rl PROPOSED RIGHT SIDE ELEVATION 1/411 = I f-011 A CERTIFIED AS BUILT IS REQUIRED BEFORE FINAL INSPECTION NOTE: CONTRACTOR TO SITE VERIFY ALL EXISTING V5 PROPOSED CONDITION5 PRIOR TO AND DURING CONSTRUCTION AND MAr\f: MODIfICATION5 A5 NECE55ARY TO PROVIDE COMPLIANCE WITI1 DE51GN PARAMETERS A5 ILLU5TKATED. rEALTH DEPT. CV Ln PROPOSED SHINGLE SIDING DETAIL 1" = 1,-0,, PROPOSED ROOF DECK DETAIL I. = 1,-0" RMI-1,1k.DFOR BUNILDING AND ANCE. ERRORS OR OI J'llllpss�o(-" APPLICk-IT FROM THE RES'PONSIBILIll OF 'AS BUI-7 COMPLIANC�J'-.' DATE: 1 X6 TREX (OR EQUAL) DECKING OVER I X6 SLEEPERS 100 ML RUBBER MEMBRANE ROOFING OVER 3/4" T&G PLYWOOD OVER 2X6 T&G, V-GROOVE DECKING ALUMINUM GUTTER (2) 2X 1 O'S @ 12" 0. C. CUT TO 1/8" SLOPE TO OUTSIDE WALL BLOCKING 4X6 P.T. CONTINUOUS TO SONOTUBE PLYWOOD &SHINGLES 2X4 BLOCKS PROPOSED ROOF DECK POST DETAIL NO SCALE NOTE: THESE PLANS ARE IN COMPLIANCE WITH THE MASSACHUSETTS STATE BUILDING CODE NINTH EDITION / 140 MPH WIND ZONE n o E @) 0 to Q C) IV CD O w 0 IL 0 ry Ln Ln 0 U) z 0 F- z 0 w W > 0 2 06 0 OC F- Z z 0 W w cg w u- uj Z w U) 4c 0 0 0 C9 Z CL 0 0 w w- CL C4 w F- DATE: 10/14/22 SCALE: AS NOTED IRAIIING #: Al a?