HomeMy WebLinkAbout34 glenwood st plan 1a
YAS 2- -
�-S4 PROPOSED EXISTING
PROP. CUSTOM CUPOLA �,A <
COPPER Roof
4"(+1-) BASE ILAIR COPPER CAP
STONE VENEER
ASPHALT ROOF SHINGLES
12
9.25
001
CEILING HT. CEDAR SHINGLE SIDING PROPOSED NEW ASPHALT SHINGLE ROOF
MATCH EXIST. DESIGN 4� COURSING z
(SEE DETAIL) :J
5TAINLE55 STEEL CABLE RAIL SYSTEM
4X6 POSTS, BOXED OUT TO 12" WIDE,
W.C. c MATCHSHINGLES EXIST. DESIGN *(TYPICAL) COURSING
I X4'5 @ (SEE DETAIL)
161, O.C.
+
�INE Of EX15T.
(3) 2X85 WALL/ ROOF L GUTTERS DOWNSPOUTS
PROPOSED PORCH EXTENSION I EXIST. PORCH ROOF
SECOND FLR
TOP PLATE TOP PLATE
01 T H I ALIGN TO EXIST. HDR
EHI �l I I I I I L A A --T
0 -7-
4X4 BRACKETS -011
EXIST.
DOOR -1 PROP. ALUMINUM SCREEN
UU, Ln
11 11 FRAMED INSERTS
+ EXISTINGHOUSE Lis
-
EXISTING FIRST f LR ------ EXISTING f I R5T f LK
H PROF. PORCH FLOOR
r%
F-;
91 W. X &H, O.H. DOOR PROP. POR6H�ADDITION
(LVL HEADER CORi JER TO CORNER)
c? ICRtAWL
I I SPACE S2 si
— — — — — — — — — — — — — — — — — — L,--- -- J 6 6
-- — — — — — — — — — — — — — — — — — -- L
5 1 EXIST. FULL BASEMENT 1
8 6 j 1
Fi- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- j
PROPOSED
FRONT ELEVATION
CEDAR SHINGLE 511
MATCH EXIST. DE51
(SEE DETAIL)
EXPAND EXISTING
FRONT PORCH
r-mut-. l)k-,mccINcL-) rum�,rl
PROPOSED
RIGHT SIDE ELEVATION
1/411 = I f-011
A CERTIFIED AS BUILT IS REQUIRED
BEFORE FINAL INSPECTION
NOTE:
CONTRACTOR TO SITE VERIFY ALL EXISTING V5
PROPOSED CONDITION5 PRIOR TO AND DURING
CONSTRUCTION AND MAr\f: MODIfICATION5 A5
NECE55ARY TO PROVIDE COMPLIANCE WITI1
DE51GN PARAMETERS A5 ILLU5TKATED.
rEALTH DEPT.
CV
Ln
PROPOSED
SHINGLE SIDING DETAIL
1" = 1,-0,,
PROPOSED
ROOF DECK DETAIL
I. = 1,-0"
RMI-1,1k.DFOR BUNILDING AND
ANCE. ERRORS OR OI J'llllpss�o(-"
APPLICk-IT FROM THE RES'PONSIBILIll OF 'AS BUI-7
COMPLIANC�J'-.'
DATE:
1 X6 TREX (OR EQUAL) DECKING
OVER I X6 SLEEPERS
100 ML RUBBER MEMBRANE ROOFING
OVER 3/4" T&G PLYWOOD
OVER 2X6 T&G, V-GROOVE DECKING
ALUMINUM GUTTER
(2) 2X 1 O'S @ 12" 0. C. CUT TO
1/8" SLOPE TO OUTSIDE WALL
BLOCKING
4X6 P.T. CONTINUOUS TO SONOTUBE
PLYWOOD &SHINGLES
2X4 BLOCKS
PROPOSED
ROOF DECK POST DETAIL
NO SCALE
NOTE: THESE PLANS ARE IN COMPLIANCE WITH THE MASSACHUSETTS STATE BUILDING CODE NINTH EDITION / 140 MPH WIND ZONE
n
o
E
@)
0
to
Q
C)
IV
CD
O
w
0
IL
0
ry
Ln
Ln
0
U)
z
0
F-
z
0
w
W
>
0
2
06
0
OC
F-
Z
z
0
W
w
cg
w
u-
uj
Z
w
U)
4c
0
0
0
C9
Z
CL
0
0
w
w-
CL
C4
w
F-
DATE:
10/14/22
SCALE: AS NOTED
IRAIIING #:
Al a?