HomeMy WebLinkAbout92 Phyllis Dr plans 3ROOF /CEILING CONSTRUCTION:
ASPHALT SHINGLES
20# ROOFING FELT
5/8" PLYWD SHEATHING
2X8 ROOF RAFTERS
R-48 SPRAY FOAM INSULATION
VAPOR BARRIER
STRAPPING + 1/2" GWB
SIMPSON H2.5A
RAFTER TIE,
TYP. EVERY RAFTER
BALLOON FRAME GABLE WALL
WALL CONSTRUCTION:
CEDAR WALL SHINGLES
TYVEK HOUSE WRAP
2X6 WALL FRAMING
R-20 BATT INSULATION
VAPOR BARRIER
112" GWB
-----------------
FLOOR CONSTRUCTION:
FINISH FLOOR
3/4" PLYWD. SHEATHING
2X8 P.T. FLOOR JOISTS
R-48 SPRAY FOAM INSULATION
RAFTER TIES: 2X6 SET DIRECTLY
BELOW RIDGE BOARD,
@ EVERY RAFTER, TYP.
G.C. TO VERIFY PITCH
& MATCH EXISTING 12
71 '00
SIMP50N AC6 CAP
TYP. ALL P05T5
5IMP50N ASU66
W/ 5/8" DIA X 7"
EMBEDMENT ANCHOR
TYP. ALL POSTS
2Xlo
SET WINDOW HEAD HEIGHTS
50 HEAD TRIMS ALIGN WITH
SLIDING DOOR
COLLAR TIE: (3) 2x10
16"MAX. ABOVE WALL HEIGHT& SANDWICHED
BETWEEN 2 RAFTERS.
FASTEN W/(2) 5/8" DIA. THRU BOLTS & WASHERS
W/ 2" WOOD EDGE DISTANCE
COLLAR TIE MUST BE LOCATED
ABOVE SOLID WALL BETWEEN OPENINGS
TOP OF PLATE
VERIFY WITH DOOR
MANUFACTURER
TOP OF SUBFLOOR
@ SUNROOM
SET NEW 5UNROOM SUBFLOOR
7" BELOW EXISTING SUBFLOOR
�z
w0
w o
_cr-
w
0OLU0
U�w
LL�==
>oo
Ll
+z
vap0<
coU)0�
�-z'oz
oz�
in <t
U)0
0
~w
U)
EXISTING
LEACHING FIELD
VERIFY LOCATION
10'-3"
EXISTING FACE OF
D-BOX FRAME
VERIFY LOCATION
0
N CANTILEVER GIRT5 TO
AVOID CONFLICT WITH C.L.
SEPTIC COMPONENTS
3
S-2.1
EXISTING
LEACHING FIELD
VERIFY LOCATION
1
A-3.1
-10"
V
NOTE:
ALL SEPTIC COMPONENTS SHOWN
ARE BASED ON THE DRAWING:
CERTIFIED PLOT PLAN
#92 PHYLLIS DRIVE
BY EAS SURVEY, INC.
DATED 10-28-2022
TRIPLE MEMBER @ END
BELOW GABLE WALL.
CONNECT TO GRTS W/
SIMPSON HUC OR LUC28-3
U
v
I F
o
h a j
co
N�
EXISTING
SEPTIC TANK
VERIFY LOCATION
TYPICAL FOOTING:
10" SONOTUSE ON
24" DIA. SPREAD FOOTING
TYPICAL POST:
6X6 P.T. ON
------SIMPSON ABU66
W/ 5/8" DIA X 7"
EMBEDMENT ANCHOR11 3
S-2.1
I
I
I
JI
I
IL
q I
LF#
I
LEDGER:
2X10 P.T. ATTCH TO CONC WALL
o
I
W/
LU
tj
I
(2) LEDGERLOK5 PER 16"
i
FACE OF FNDN.
I
CONNECTION TO LEDGER:
5IMP50N LU5210-3 TYP.
Footings &
Floor Framing
Plan
1
SCALE:114"
GABLE WALL
TO BE SALOON FRAMED
16" MINIMUM
�y2 Qao
THIS HEADER ONLY:
16" MINIMUM
SHEATHED CORNERS
�J =
(3) 2X6 CONTINUOUS
SHEATHED CORNERS
@ EXTERIOR, BOTH DIRECTIONS.
�' oc�� y0�
@ EXTERIOR, BOTH DIRECTIONS.
l>>S
RIDGE BOARD:
65
2X10
RAFTER TIES:
2X6 SET DIRECTLY BELOW RIDGE
o
BOARD, @ EVERY RAFTER
Z
H
Z v�
COLLAR TIE: (3) 2x10
0 0
16"MAX. ABOVE WALL HEIGHT& SANDWICHED
m
v
BETWEEN 2 RAFTERS.
N a
FASTEN W/(2) 5/8" DIA. THRU BOLTS & WASHERS
z
COLLAR TIE MUST BE LOCATED
o�
�X
ABOVE SOLID WALL BETWEEN OPENINGS
j Z
N
(2
6?)
Sq�KS
Lo w
JAGS
x��
ow
�z�
�oo
of U
0
oLU
w
= n
P0�
ll
�ZNGS
EXTERIOR SHEATHING
P0�'<3��SNGS
MUST REMAIN IN PLACE
�1l
THIS SIDE OF WALL.
_
HEADER: (2) 2X10
HEADER SUPPORTS:
(1) JACK, (3) KINGS
@ EA. END
MICHELE '
u- CUDILO ,
O
° No.34774
STFtUCTLIV'AL f +
ac _�
>
O
/
Z
9 ::4 t.,
A co
T 1 cq
06 0 N
v 9 w
�ob
Q1 rn �o
�a
A
V'
N
N
OP4
O
P
PC
N
®
tcS
:j �
�
N
cd 00
W
A
ob
0
O
co
V�
R3
r
o
cn
O
W
5
a)
'::4
C
p
�
.�
^�
A
�
A>_4
a
N
z
N
�0
�
N
ro
a
v
Building Section
SCALE: 1 /2" = l'-0"
D^rNf Cr,-%r ;r,n Cil--%r%
SCALE:1/4" = l'-0"
C\l