Loading...
HomeMy WebLinkAbout453 Station Ave CVS plan 1Q 00 Ln N N O N 00 03 45� '�TATnNl AVF �nHTH YARMOU 0 CL CVS STORE NO. 00944 LLJ m CD ch DRAWING INDEX Cn ■ G1 COVER SHEET ■ G2 RESPONSIBILITY MATRIX & OVERALL SCOPE OF WORK ■ G3 GENERAL NOTES & SPECIFICATIONS ■ G3.1 SPECIFICATIONS ■ G3.2 SPECIFICATIONS ❑ G4 NOT USED FIXTURE PLAN ■ F1 MERCHANDISE PLAN ARCHITECTURAL ■ AD1 DEMOLITION FLOOR PLAN ■ AD2 DEMOLITION REFLECTED CEILING PLAN ■ Al OVERALL FLOOR PLAN ■ A2 REFLECTED CEILING PLAN ■ A3 DEMO&NEW TOILET ROOM PLANS, ELEVATIONS & DETAILS ■ A4 FINISH PLAN ■ A5 INTERIOR ELEVATIONS ■ A5.1 FINISH SCHEDULE ■ A6 ACCESSIBLE DETAILS ■ A7 DOOR SCHEDULE NOTES & DETAILS ■ RX1 CONSULTING ENLARGE PLAN & ELEVATIONS CIVIL ❑ AC1 NOT USED STRUCTURAL ❑ AS1 NOT USED MECHANICAL/PLUMBING ❑ AM1 NOT USED ❑ AM2 NOT USED ❑ AP1 NOT USED ❑ AP2 NOT USED ELECTRICAL ■ AE1 ARCH. ELECTRICAL SPECIFICATIONS ■ AE1.1 ARCH. ELECTRICAL SPECIFICATIONS ■ AE2 SYMBOLS, RISER DIAGRAM & LOAD SUMMARY ■ AE3 ARCH. LIGHTING PLAN ■ AE4 ARCH. POWER PLAN TH, MA 02 4 REVIEWED r�' ;i-E COMPLI. ANCE. ERROI S 'Rl_LIEVE THE APPLICANT FROM THE k,Sj_vU1 Q`dLi lY O "AS.BUILT" COMPL IANCE. DATE: 664 �LIiLDhlCi OFFICIAL TEAM MEMBERS BUILDING CODE & STANDARDS LOCATION MAP ARCHITECT: WILLIAM STARCK ARCHITECTS JEFF KERN" THE BUILDING SHALL BE IN COMPLIANCE WITH THE FOLLOWING: . ; 126 COVE STREET TEL: (508) 679-5733 2015 INTERNATIONAL BUILDING CODE (IBC) 1.0 $ ,..$ FALL RIVER, MA, 02720 FAX: (508) 672-8556 (WITH MASSACHUSETTS AMENDMENTS — 780 CMR 9TH EDITION) 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) MASSACHUSETTS COMPREHENSIVE FIRE SAFETY CODE (527 CMR) � CVS CVS PHARMACY, INC. SUSAN HUEMMER 2015 INTERNATIONAL MECHANICAL CODE (IMC) ������ ' SENIOR 1 CVS DRIVE TEL (240) 810-2485 (WITH MASSACHUSETTS AMENDMENTS - 780 CMR 12.00) ,dt PROJECT WOONSOCKET, RI 02895 MASSACHUSETTS UNIFORM STATE PLUMBING CODE (248 CMR 10,00) MANAGER: MASSACHUSETTS STATE FUEL GAS CODE (248 CMR 3.00 THRU 8.00) t 1410 2018 INTERNATIONAL ENERGY CONSERVATION CODE IECC } CVS CVS/PHARMACY, INC. MICHAEL DECARVALHO (WITH MASSACHUSETTS AMENDMENTS — 780 CMR 13.00) 3 ; A&E 1 CVS DRIVE TEL: (401) 679-6522 NATIONAL ELECTRIC CODE a as n PROJECT WOONSOCKET, RI 02895 FAX: (401) 770-9100 (WITH MASSACHUSETTS AMENDMENTS — 527 CMR 12.00) MANAGER: NFPA 101 LIFE SAFETY CODE IV 1A ARCHITECTURAL ACCESS BOARD (521 CMR) AND 101„, TENANT: CVS PHARMACY, INC. 2010 FEDERAL ACCESSIBILITY GUIDELINES 1 CVS DRIVE WOONSOCKET, RI 02895 TEL: (401) 765-1500 GENERAL NOTE TO PLAN EXAMINER: MAP DATA C) 2022 GOGGLE SITE LOCATION NO CHANGE TO EXISTING BUILDING USE. ONE TOILET ROOM TO REMAIN LANDLORD: SCP 2009—C32-512, LLC—CMP29455 OPEN AT ALL TIMES DURING CONSTRUCTION AS REQUIRED ON APPLICATION c/o LAWRENCE KADISH REAL ESTATE SITE KEY PLAN N.T.S. 135 JERICHO TURNPIKE TOTAL BUILDING SQ. FT.: 11,838 S.F OLD WESTBURY, NY 11568 TEL: (516)334-9730 CONT: VALARIE BALLEIN EXISTING PROPOSED CURRENT OCCUPANT CVS/PHARMACY CVS/PHARMACY CONTRACTOR: T.B.D. —CONTRACT NOT YET AWARDED TYPE OF BUSINESS RETAIL RETAIL TYPE OF CONSTRUCTION IIIB IIIB` _ BUILDING USE GROUP MERCANTILE MERCANTILE h HEIGHT/NO. OF STORIES 1 STORY 1 STRY - HIGH RISE (Y/N) N N FULLY SPRINKLERED (Y/N) Y Y EGRESS DISTANCE: 186'-2" 186'-2„�$ PROJECT DESCRIPTION: (AREA OF WORK: ±870 SF) MODIFICATIONS OF THE EXISTING PHARMACY, RETAIL, AND CHECKOUT AREAS. NEW FINISHES THROUGHOUT. MINOR MODIFICATIONS TO MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS. SYMBOLS A CENTERLINE OF _ _ xx ENLARGED PLAN COLUMN xxx DETAIL MARK I SECTION MARK xx ELEVATION MARK. xx 'SIM' — SIMILAR xxx xxx 'OH' — OPPOSITE HAND ABBREVIATIONSUSBEDRONATHE RE NOT NECESSARILY DRAWINGS) A C (CONTINUED) E (CONTINUED) H (CONTINUED) M P (CONTINUED) J (CONTINUED) V AB ANCHOR BOLT CONT CONTINUOUS, CONTINUATION EXP EXPANSION HVU HEATING AND VENTILATING UNIT MAX MAXIMUM PDU POWER DISTRIBUTION UNIT SHT SIM SHEET SIMILAR V VA VOLT VOLT-AMPERE A/C AIR CONDITIONING COORD COORDINATE EXIST EXISTING HVY HEAVY MDP MECH MAIN DISTRIBUTION PANEL MECHANICAL PERP PH PERPENDICULAR PHASE SHT MTL SHEET METAL VERT VERTICAL AC ALTERNATING CURRENT CR CJ CONDENSATE RETURN CONTROL JOINT EXT EXTERNAL, EXTERIOR MEZZ MEZZANINE PT PAINT SPEC SPECIFICATION VIF VERIFY IN FIELD ACI AMERICAN CONCRETE INSTITUTE CTR CENTER EW EWC EACH WAY ELECTRIC WATER COOLER ( MFR MANUFACTURER PL PLATE SQ SQUARE VRC VERTICAL RECIPROCATING ACCESS ADA ACCESSORIES AMERICANS WITH DISABILITIES CV CHECK VALVE MH MANHOLE, METAL HALIDE PLBG PLUMBING SS STAINLESS STEEL, SANITARY SEWER VTR CONVEYOR VENT THROUGH ROOF ACT CW COLD WATER ID INSIDE DIAMETER MIN MLO MINIMUM MAIN LUGS ONLY PNL PIV PANEL POST INDICATOR VALVE STC SOUND TRANSMISSION CLASS ADD'L ADJ ADDITIONAL ADJUSTABLE E INT INVERT ELEVATION INTERIOR MO MASONRY OPENING PSF POUNDS PER SQUARE FOOT STLD STEELSTANDARD AFF ABOVE FINISHED FLOOR INTER IN INTERMEDIATE INCH, INCHES MSB MTD MAIN SWITCHBOARD MOUNTED PVC PWD POLYVINYL CHLORIDE, PLYWOOD STIFF STIFFENER �!v AFP ABOVE FINISHED PLATFORM D FA FIRE ALARM STIR STIRRUPS V ALUM AMP ALUMINUM AMPERE, AMPS DBL DOUBLE FRCP FCO FIRE ALARM CONTROL PANEL FLOOR CLEANOUT INSUL ISA INSULATION INTERNATIONAL SYMBOL OF N STRUCT SUSP STRUCTURAL SUSPENDED W/ WITH ARCH ARCHITECT, ARCHITECTURAL DC DIRECT CURRENT FD FIRE DAMPER, FLOOR DRAIN ACCESSIBILITY Q SYMM SYMMETRICAL W/O WITHOUT ASHRAE AMERICAN SOCIETY OF HEATING, DEG DEGREES FIN FINISH (ED) N/A NOT APPLICABLE SJ SAW JOINT WCO WALL CLEANOUT REFRIGERATION AND AIR DEFS DIRECT -APPLIED EXTERIOR FINISH FIXT FIXTURE NEC NATIONAL ELECTRICAL CODE QTY QUANTITY SOA SECURITY OBSERVATION AREA WC WATER CLOSET CONDITIONING ENGINEERS SYSTEM " FDN FOUNDATION NEMA NATIONAL ELECTRICAL WD WOOD ASTM AMERICAN SOCIETY OF TESTING DGG DENS -GLASS GOLD FLG FLANGE MANUFACTURER'S ASSOCIATION WL WIND LOAD AND MATERIALS DIA DIAMETER FTG FS FOOTING FAR SIDE J-BOX JUNCTION BOX NF NEAR FACE T WP WEATHERPROOF AVG AVERAGE DIM DIMENSION JT JOINT NFPA NATIONAL FIRE PROTECTION I WO WALL OPENING DL DEAD LOAD FF FINISHED FLOOR JST JOIST ASSOCIATION T&B TOP AND BOTTOM WWF WELDED WIRE FABRIC DN DS DOWN DOWNSPOUT FLR FLUOR FLOOR FLUORESCENT NIC NOT IN CONTRACT RA RETURN AIR T/FTG TOP OF FOOTING WF WIDEHFLANGE (STRUCTURAL) DTL DETAIL FIR FIRE-RETARDENT-TREATED K NL NIGHT LIGHT RAP RADIUS THICK THICKNESS BC BUILDING CONTRACTOR DWGS DRAWINGS MATERIALS NO NOM NUMBER NOMINAL RCP REFLECTED CEILING PLAN THRESH TO THRESHOLD TOP OF BLDG BM BUILDING BEAM FT FRP FOOT, FEET FIBERGLASS REINFORCED PANEL k KIPS (1000 LBS) NTS NOT TO SCALE RD ROOF DRAIN TOJ TOP OF JOIST BOTT BOTTOM kV KILOVOLT RE: REINF REFERENCE, REFER REINFORCING TOS TOP OF STEEL BTU BRITISH THERMAL UNIT BOTTOM OF FOOTING E kVA kW KILOVOLT -AMPS KILOWATT O READ REQUIRED THRU T THROUGH THERMOSTAT BOF kWH KILOWATT-HOUR RHO RETAIL HEALTH CENTER TYP TYPICAL XFMR TRANSFORMER BRG BEARING EA EC EACH ELECTRICAL CONTRACTOR GA GAUGE RM RO ROOM ROUGH OPENING TS THICKNESS (STRUCTURTEMPERATURE SENSOR AL) EF EXHAUST FAN GALV GALVANIZED OC ON CENTER RPM REVOLUTIONS PER MINUTE T&G TONGUE AND GROOVE EJ EXPANSION JOINT GC GENERAL CONTRACTOR I OCC OF OCCUPANTS OUTSIDE FACE RTU ROOFTOP UNIT TR WOOD PRESERVATIVE -TREATED ELEV EIFS ELEVATION EXTERIOR INSULATION AND GB GWB GRADE BEAM GYPSUM WALL BOARD LB L POUNDS OD OUTSIDE DIAMETER TS MATERIALS TUBULAR STEEL (STRUCTURAL) , Y CF CUBIC FEET FINISH SYSTEM GAB GRADED AGGREGATE BASE LF LINEAR FEET OH OPNG OPPOSITE HAND OPENING S TRS R TRUSS (STRUCTURAL) CERTS CERTIFICATES ELEC ELECTRICAL ILL LIVE LOAD, LANDLORD OSHA OCCUPATIONAL SAFETY AND YD YARD CFM CKT CUBIC FEET PER MINUTE CIRCUIT EMBED EMP EMBEDMENT EMPLOYEE H LLH LO LONG LEG HORIZONTAL LONG LEG VERTICAL HEALTH ADMINISTRATION SC SITE CONTRACTOR CENTERLINE EMS ENERGY MANAGEMENT SYSTEM LONG LONGITUDINAL SCHED SCHR SCHEDULED SECONDARY CHILLED WATER v CLG CLR CEILING CLEAR OR CLEARANCE ENCL ENT ENCLOSURE ENTRY, ENTRANCE HGT HORIZ HEIGHT HORIZONTAL LT LIGHT p RETURN UL UNDERWRITERS LABORATORIES, CMU CONCRETE MASONRY UNIT EQ EQUAL HP HORSEPOWER OR HIGH POINT LP LOW POINT LIGHTING SD SMOKE DAMPER, STORM DRAIN UON INC. UNLESS OTHERWISE NOTED CO COL CLEANOUT COLUMN EQUIP EXGR EQUIPMENT EXTERIOR GRADE HTR HVAC HEATER HEATING, VENTILATING AND AIR LTG LWC LIGHT WEIGHT CONCRETE PAR P/C PARALLEL PRECAST CONCRETE SECT S SECTION SENSOR UPS UNINTERRUPTIBLE POWER CONC CONCRETE, CONCENTRIC EXH EXHAUST CONDITIONING L LENGTH PC PIECE SF SQUARE FEET SUPPLY f- F^ 7' '� 'i 1 `• Gd;;j Y RECEIVED OCT o 4 za22 BUILDING DEPARTMENT 13Y -- --- Ito RESET STORE NUMBER 00944 453 STATION AVENUE SOUTH YARMOUTH, MA 02664 CAP CODE: 00072 CS PROJECT NUMBER 163445 "4 STARCK ARCHITECTS 126 Cove Street Fall River, MA 02720 1 Richmond Square, Suite 120C Providence, RI 02903 MA 508.679.5733 RI 401.709.7799 STARCKARCHITECTS.COM CONSULTANT ENGINEER CONSULTANT SEAL ED aRc s i 951251 o J� ✓F�4 OF MPSSPG REVISIONS: DRAWING/REVIEWED BY: PPY/MJT CVS PROJECT MANAGER: SH DATE: 08/08/2022 JOB NUMBER: 163445 lulls, COVER SHEET SHEET NUMBER: G1_ COMMENTS: