HomeMy WebLinkAbout453 Station Ave CVS plan 11Rx WAITING
111
8'-11 11 16"
\\\\\\ 0
(CLOSED) HH (CLOSED) HH
EXAM ROOM #1 EXAM ROOM #2
115 116
7'-11 11 /16" 7'-11 5/16»
�---- ---- — ___________________-
II--------- - �i FF______________�'
I
I o �I iI
� I I
7
11
I
8
9
I
i WALK-IN
/ /
I I
I COOLER
I
8 DOORS
I
°
I
/
O
I
I
iI
Ii
ITUT
7
7
II
II
I1
I
II
HM
H_
II
II
//
147777
I
I�
/
■
■
■
8
11
II
444
I
jI
®
0
0
9 CE
I TER OF
0
10
1
0
0
0
1
0
0
LO
II
8
qCE
0
PHARMACY
I I
I
17 110 I
I.
T-0» I i
I
IF-77M-7-1
.... ......
Z.
Big
12
VVUIVltIYJ
RESTROOM
I
1 88
8'-0"
I
77
12
MEN S
I
.:;:
�TTY
11
IL
RESTROOM
I
10-7
�I
8'-0"
EMPLOYEE
12
LOUNGE
1-05-1
II
0
0 11
8'-0"
I
II
I I
II
II �
II __
II °
II
RECEIVING 1
AREA II
006
B.O.J: 13'-3 1 /8
B.O.D: 14'-3 3/4 11
li •
MANAGER'S
OFFICE
_0471
7'-11 1 /8" 15
REFLECTED
CEILING PLAN
A2 1/8" = 1'-0"
LEGEND
EXISTING PARTITION TO REMAIN
NEW GYPSUM WALLBOARD CEILING
NEW PARTITION
-'�
KEY NOTE DESIGNATION
NEW ACOUSTICAL CEILING TILE
AND CEILING GRID
coy.
REF.
EXISTING ACOUSTICAL CEILING TILE
TO REMAIN
REF:
COLUMN GRID
FIXTURE DESIGNATIONS
EXISTING CEILING JOIST TO
REMAIN
NOT LABELD/ E EXIST. TO REMAIN
D DEMOLISH
®. ®
NEW CEILING JOIST
RE/ER RELOCATE
N NEW
CEILING FIXTURE SCHEDULE
EXISTING/DEMO/NEW SYMBOL
DESCRIPTION
®
®
2x4 LIGHTS
STRIP LIGHTS
LED MONOPOINT WITH ELIPTICAL LENS
AIM DIRECTLY AT PHARMACY SIGNAGE
lBE(
EXIT SIGNS
08
D
a
EMERGENCY LIGHTS
Lr �J
��
MIRRORED CEILING PANEL
®
®
®
POWER POLE
o
L
OO
SPEAKER
SECURITY CAMERA BUBBLE
rrl
/•�
n
SECURITY MOTION SENSOR
0 ceiling
® ceiling
ceiling
FIRE ALARM STROBE LIGHT/SOUNDER STROBE
a ®
1-TV 2-TV
1-' V p
� �
1-TV 2-TV
C. C. T. V.
�(
�(
WIR ROUTER
1�
f�
SPRINKLER HEAD
�y
HVAC SUPPLY
L >J
HVAC RETURN
zry
HVAC EXHAUST/TRANSFER GRILLE
®
®
EXHAUST FAN
SPLIT SYSTEM HVAC - CEILING AHU
UH
M=41GAS
FIRED UNIT HEATER
EGGCRATE TILE
NOTES BY SYMBOL (®)
1.
G.C. TO PURCHASE AND INSTALL UP TO
6.
CLEAN EXISTING DIFFUSERS AS SHOWN.
4 BOXES (32) OF CEILING TILES TO
REPLACE STAINED/DAMAGED CEILING
7.
INSTALL NEW POWER DROPS/POWER
TILES THROUGHOUT RETAIL.
POLES AS SHOWN (WHITE) RE: 1/AE4
2.
GC TO COORDINATE WITH CVS VENDOR
8.
MODIFY EXISTING GRID AND INSTALL NEW
FOR RELOCATION/NEW SECURITY
CEILING TILES AS SHOWN.
EQUIPMENT, INCLUDING CAMERAS &
MOTION DETECTORS.
9.
INSTALL NEW/RELOCATED LIGHT FIXTURES
AS SHOWN/SCHEDULED. RE: ELECTRICAL
3.
REPLACE PHYSICALLY DAMAGED/
BROKEN/MISSING CEILING TILES. REPLACE
10.
INSTALL NEW LIT ISA EXIT SIGN AS
TILES THAT ARE MORE THAN 60%
SHOWN. RE: ELECTRICAL
STAINED; PAINT ALL MINOR STAINED
(LESS THAN 60%) CEILING TILES W/
11.
REPLACE EGGCRATE CEILING TILES AS
PROCOAT "WHITE" CEILING APPLICATION
SHOWN.
4.
RELAMP AND REBALLAST ALL
12.
PATCH AND PAINT EXISTING CEILING
NON -WORKING LIGHT FIXTURES AS
REQUIRED. G.C. TO PROVIDE ADDITIONAL
13.
FIX CEILINGS TILES AS REQUIRED
BOX EACH TYPE OF BULB FOR
FUTURERE STORE USE.
14.
INSTALL NEW MONOPOINT LIGHTS AT THE
MINIMUM DISTANCE OF 48" TO 53" OFF
5.
CLEAN EXISTING MIRRORS AND MIRRORED
THE VERTICAL SOFFIT. CENTER FIXTURES
CEILING TILES & INSTALL RELOCATED
TO SIGNAGE AND SPACE THEM 5 FT
EXISTING MIRRORED CEILING TILES AS
APART. RE: ELECTRICAL
REQUIRED.
15,
REPLACE DAMAGED/STAINED CEILING
TILES AS REQUIRED
PRESET
STORE NUMBER: 00944
453 STATION AVENUE
SOUTH YARMOUTH, MA 02664
CAP CODE: 00072
CS PROJECT NUMBER: 163445
"4
STARCK
ARCHITECTS
126 Cove Street
Fall River, MA 02720
1 Richmond Square, Suite 120C
Providence, RI 02903
MA 508.679.5733
RI 401,709.7799
STARCKARCHITECTS.COM
CONSULTANT ENGINEER
CONSULTANT:
SEAL:
ED ARC
VF1/0<"\C
2 �Q
951251
J`6
✓F94 N FM
REVISIONS:
DRAWING/REVIEWED BY: PPY/MJT
CVS PROJECT MANAGER: SH
DATE: 08/08/2022
JOB NUMBER: 163445
TI TLE:
REFLECTED
CEILING PLAN
SHEET NUMBER:
A2
COMMENTS: