Loading...
HomeMy WebLinkAbout453 Station Ave CVS plan 17TYPICAL HOLLOW METAL DOOR IN GWB CONSTRUCTION INTERIOR HEAD DETAIL A% SCALE: 1 1/2" = V-0" TOP OF METAL DECK OBOTTOM OF MTL DECK VERTITRACK VTD 362-16 BY STEEL NETWORK, INC. INSTALL PER MFR RECOMMENDATIONS. USE (2) #10 TEK SCREWS © 16" O.C. TO EXISTING FLOOR DECK 5/8" GWB METAL STUD PER SCHEDULE PERPENDICULAR TO METAL DECK - 1" DEFLECTION 4 SLIP JOINT A7 SCALE: 1 1/2" = V-0" EYE BOLT AIRCRAFT WIRE SUPPORT 10� 2'-71/2" • SMALL 3-SIDED TRIANGULAR AISLE _ MARKER TO BE USED WHEN CLG HT = 9'-3" TO 15'-0" AFF • REFER TO SIGNAGE MANUAL FOR INSTALLATION INSTRUCTIONS 6 AISLE MARKER ELEVATION 1 /8" = 1'-0" Q0 0 00 N 0 N 03 T) TYPICAL HOLLOW METAL DOOR IN GWB CONSTRUCTION _ANT, EA SIDE R FRAME R, AS SCHED 2 INTERIOR JAMB DETAIL A7 SCALE: 1 1/2" = V-0" END PANEL TO BE CUT TO MATCH HEIGHT OF WALL FIXTURE FIXTURE POST Q STRAPPING NOT TO EXTEND BEYOND TOP OF FIXTURE - COORDINATE WITH x U- FIXTURE HEIGHTS ON 7D Z:) FINAL MERCHANDISE 00 x x PLAN LLJ =(-,1 00 END PANEL BEYOND 1x3 WOOD STRAPPING, FASTENED TO WALL = FOR FIXTURE SUPPORT 00 w/ 1 1 /2" LONG SCREWS w/ WASHERS (INSTALLED BY o �i CONTRACTOR) FIXTURE BASE END PANEL TO EXTEND 2" BEYOND FIXTURE BASE SUPPORT DETAIL %^5 WALL UNIT FIXTURE SCALE: 1/2" = V-0" TCEILING AIRCRAFT WIRE SUPPORTS EYE BOLTS check priceeh re B.O. MARKER 7-w ELEV. PRICE CHECKER (7� SIGNAGE DETAIL A% SCALE: 1/2" = V-0" DOOR, AS SCHED DOOR FRAME BEYOND FINISH AS SCHED FINISH AS SCHED RE: SHEET A4 INTERIOR THRESHOLD DETAIL SCALE: 1 1/2" = 1'-0" END PANEL TO BE CUT TO MATCH HEIGHT OF FIXTURE _ HEADER SIDEWALL FIXTURE HEADER STRAPPING NOT TO j EXTEND BEYOND TOP x OF FIXTURE 1x3 WOOD STRAPPING, J FASTENED TO WALL FOR o FIXTURE SUPPORT w/ 1 1/2" z LONG SCREWS w/ WASHERS '�2' (INSTALLED BY CONTRACTOR) z FIXTURE POST ii o END PANEL BEYOND `z 1x3 WOOD STRAPPING, -_ FASTENED TO WALL FOR FIXTURE SUPPORT w/ 1 1/2" LONG SCREWS w/ WASHERS �i (INSTALLED BY CONTRACTOR) FIXTURE BASE END PANEL TO EXTEND 2" BEYOND FIXTURE BASE NOXELL FIXTURE HEADER STRAPPING NOT TO EXTEND BEYOND TOP OF FIXTURE 1x3 WOOD STRAPPING, ,L, FASTENED TO WALL FOR FIXTURE SUPPORT w/ 1 1/2" x LONG SCREWS w/ WASHERS (INSTALLED BY CONTRACTOR) Q FIXTURE POST END PANEL BEYOND @) 1x3 WOOD STRAPPING, c2 FASTENED TO WALL FOR FIXTURE SUPPORT w/ 1 1/2" LONG SCREWS w/ WASHERS o o (INSTALLED BY CONTRACTOR) _ FIXTURE BASE END PANEL TO EXTEND 2" BEYOND FIXTURE BASE - 1x3 WOOD STRAPPING, FASTENED TO WALL FOR FIXTURE SUPPORT w/ 1 1/2" LONG SCREWS w/ WASHERS (INSTALLED BY CONTRACTOR) - —FIXTURE POST 1 x3 WOOD STRAPPING, FASTENED TO WALL FOR FIXTURE SUPPORT w/ 1 1/2" LONG SCREWS w/ WASHERS 1 ( (INSTALLED BY CONTRACTOR) FIXTURE BASE END PANEL TO EXTEND 2" �. BEYOND FIXTURE BASE DOOR AND FRAME SCHEDULE DOOR FRAME FIRE RATING HARDWARE SIZE LOUVER DETAIL TYPMATL F- GLAZING MATL LABEL SET N0. NOTES HGT THK WD HGT HEAD JAMB SILL 21. M 3'-1" 2'-10" WD CORE — — -- — — — 8,9 26. C 3'-O" 6'-8" 1-4" SOLID WD HM 1/A7 2/A7 3/A7 — HWS-03 1,2,3,4 27. Q 3'-0" 6'-8" 1" ACRYLIC — — — — — — 5 REMARKS: 7. QMI ROLL DOWN SECURITY GRILLE 1. STAIN PUSH/ PULL SIDE DOOR EIM FRAME PAINTED TO 8. DOOR FINISH TO BE PL2 MATCH ADJACENT WALL; GC TO CLEAN SURFACE, APPLY TWO 9. DOOR/GATE AND HARDWARE BY MILLWORK VENDOR TO THREE COATS THEN APPLY FINAL STAIN SEALANT COAT OF LENMAR ACRYLIC URETHANE AQUA -WATERBORNE SEMI -GLOSS 2. PAINT DOOR AND FRAME PT20 3. PROVIDE PRIVACY LOCKSET 4. DOOR TO HAVE 1" UNDERCUT 5. SEE DOOR TYPES FOR PACKAGE DIMENSIONS 6. FACTORY FINISH HARDWARE SCHEDULE HWS-02 HWS-03 HWS-05 HWS-07 HINGES • • • HWS-02; 3 EACH, HWS-03; 3 EACH, HWS-05, 2 EACH LOCKSET • • • 1 EACH CYLINDRICAL LOCK WITH THRU BOLTS, HWS-02; PRIVACY LOCK WITH THRU BOLTS PANIC DEVICE CLOSER • • HWS-02;1 EACH, HWS-03;1 EACH DOOR STOP • HWS-03;1 EACH KICK PLATE • THPESHOLD SILENCERS • • • HWS-02; 3 EACH, HWS-03; 3 EACH, HWS-05; 3 EACH WEATHER STRIPPING DOOR SWEEP ASTRAGAL RAIN GUARD FLUSH BOLTS NOTES • ALL DOOR HARDWARE IS PROVIDED BY DOOR MFR HEAD AND JAMB SMOKE SEALS VIEWER • • • HWS-02; 1 EA, HWS-03; 1 EA; 3 EA, HWS-05; 1 EACH (DRS 9&10 NO VIEWER) GENERAL DOOR HARDWARE NOTES: 1. DOORS, FRAMES, HARDWARE, AND LOCKING SYSTEMS SHALL BE PURCHASED FROM THE CVS NATIONAL ACCOUNT SUPPLIER 2. DOOR THRESHOLDS AND TRANSITIONS SHALL NOT EXCEED 1/2" IN HEIGHT 3. ALL DOOR KNOBS SHALL BE LEVER TYPE AND ADA ACCESSIBLE 4. DOOR CLOSERS SHALL BE ADJUSTABLE AND SET TO COMPLY WITH ACCESSIBLE CRITERIA FOR OPENING TENSION AND CLOSING SPEEDS. THE DOOR PARALLEL ARM BRACKET MUST BE INSTALLED AT THE MINIMUM 80" AFF ADA REQUIREMENT, 5. FOR CYLINDERS AND KEYING, PROVIDE AS STANDARD WITH THE MANUFACTURER FOR THE OWNER FOR THE TELESCOPING DOOR SPECIFIED. 6. FOR CONSTRUCTION KEYING, PROVIDE CONSTRUCTION CORES THAT ARE REPLACEABLE BY PERMANENT CORES. PROVIDE QUANTITY AS DIRECTED BY OWNER AND FURNISH PERMANENT CORES TO OWNER FOR INSTALLATION. 7. FOR KEYING SYSTEM, PROVIDE A FACTORY -REGISTERED KEYING SYSTEM AS DIRECTED BY OWNER. & FOR KEYS, PROVIDE NICKEL -SILVER. STAMPING MUST BE PERMANENTLY INSCRIBED WITH A VISUAL KEY CONTROL NUMBER AND INCLUDE THE NOTATION "DO NOT DUPLICATE". QUANTITY DETERMINED BY OWNER DOOR TYPES SCALE:1/8" = V-0" DESIGNATED HINGE a LOCATION, TYP. a J TWO-WAY DOOR M �_ / VIEWER PER HARDWARE SCHEDULE, 42"-45" AFF. 37" GATE PULL W/ DESIGNATED =a I� HOLES, BOTTOM SITS M d * 37 J„ AFF. LOCK, CENTER o ¢ J N vDOOR -_ C M AT 36" AFF. w Q GENERAL NOTES: 1. FIELD VERIFY ALL DOOR/WINDOW DIMENSIONS PRIOR TO FABRICATION 2. REFER TO STRUCTURAL DRAWINGS FOR ALL REINFORCING 3. AT OPENING TO HALL, PROVIDE FLUSH FRAME ONLY WITHOUT DOOR, PAINT PT20 BOTH SIDES 4. EAS PEDESTALS TO BE PAINTED PT20 5. NOT ALL WALLCOVERINGS ARE USED IN THIS PROTOTYPE BUT ARE DOCUMENTED FOR YOUR USE WHEN NEEDED WITH TIER 1, BRAND INTO RETAIL MERCHANDISE PLANS 6. SPM RESPONSIBLE FOR DETERMINING THE REPLACEMENT OF DOORS DURING SOW WALK AND TO RELAY THIS DIRECTION IN THE PROJECT'S PLAN SET. #*CVS pharmacy" RESET STORE NUMBER: 00944 453 STATION AVENUE SOUTH YARMOUTH, MA 02664 CAP CODE: 00072 CS PROJECT NUMBER. 163445 "4 STARCK ARCHITECTS 126 Cove Street Fall River, MA 02720 1 Richmond Square, Suite 120C Providence, RI 02903 MA 508.679.5733 RI401.709.7799 STARCKARCHITECTS.COM CONSULTANT ENGINEER CONSULTANT SEAL REVISIONS: DRAWING/REVIEWED BY: PPY/MJT CVS PROJECT MANAGER: SH DATE: 08/08/2022 JOB NUMBER: 163445 TI TLE: DOOR SCHEDULE NOTES & DETAILS SHEET NUMBER: A7. COMMENTS: