Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 3 0 Lot_l_na Zone of Contribution: In_ Out 'Acreage � Commercial: Residential: Village: `T�:/tL4 c -�_�-� Street: Floor Plan: 1-/--- a Bedrooms: 3 Owner: Address: Installer: //, L'3 1--Q w w Phone: Phone: D .1 Builder: Engineer: O Address: ,,) Phone: Phone: I. Required#of copies received N/A YES NO 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table % 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: „i --- 5. Water line 10 ft from septic components Var.: I ,i - 6. Benchmark indicated and shown-NGVD if near wetlands I 7. Septic tank minimum 1 from foundation. Var.: '�r// I 8. Leaching minimu 0 , 15 ft craw 10 ft slab Var.+ N MI ArAlk 9. Leaching minimum ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 1 12. System meets all other setback requirements Var.: I 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable / 17. System meets slope requirements-min. 1/8", '/"preferred 18. System meets breakout requirements PVC Iiner: Wall:19. Specified tee sizes are proper, gas baffle on outlet tee / 20. Sewage is under 10,000 gpd for parcel <,/'- 21. No garbage disposal 22. System adeguately sized for its intended use I / 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 1 26. Electrical permit for pump chamber/Separate meter for duplexes 1 27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking ,/--30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall : com mercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater I 34.Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd d 37. Check area lots for groundwater/Label groundwater in Assessor's Map I Plan reviewed by: