Loading...
HomeMy WebLinkAboutBLD-23-005067 LVL Boise Cascade Quadruple 1-3/4" x 9-1/2" VERSA-LAM® LVL 2.1E 3100 SP PASSED FB01 (Floor Beam) BC CALC®Member Report Dry 11 span I No cant. March 16, 2023 11:10:49 Build 16959 Job name: File name: 4 Runestone ne--'` / Address: 4 Runestone Road Description: ceiling beam 14 `t�� City, State,Zip: S.Yarmouth, MA Specifier: 1 Customer: Designer: Donald Spears Code reports: ESR-1040 Company: Cape Cod Lumber 1 1 . 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1.. 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Jk / 81 18-00-00 B2 Total Horizontal Product Length=18-03-08 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 1-3/4" 1783/0 1365/0 B2, 1-3/4" 1775/0 1360/0 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self-Weight Unf. Lin. (lb/ft) L 00-00-00 18-03-08 Top 19 00-00-00 1 limited access attic Unf.Area(Ib/ft2) L 00-00.00 18-03-00 Top 15 10 13-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 14137 ft-lbs 50.6% 100% 1 09-01-12 End Shear 2826 lbs 22.4% 100% 1 00-11-04 Total Load Deflection U265(0.819") 90.4% n\a 1 09-01-12 Live Load Deflection L/469(0.464") 76.8% n\a 2 09-01-12 Max Defl. 0.819" 81.9% n\a 1 09-01-12 Span/Depth 22.9 Allow %Allow Bearing Supports Dim.(LxW) Value Supporl. Member Material B1 Column 1-3/4"x 7" 3149 lbs 35.5% 34.3% Spruce-Pine-Fir B2 Column 1-3/4"x 7" 3135 lbs 35.3% 34.1% Spruce-Pine-Fir Notes Design meets Code minimum(L/240)Total load deflection criteria. Design meets Code minimum(L/360)Live load deflection criteria. Design meets arbitrary(1")Maximum Total load deflection criteria. Design based on Dry Service Condition. BC CALC®analysis is based on IBC 2009. Calculations assume member is fully braced. Connection Diagram: Full Length of Member fit b r d -- a e 1..._ Page 1 of 2 Boise Cascade` Quadruple 1-3/4" x 9-1/2" VERSA-LAM® LVL 2.1E 3100 SP PASSED er+c.meeeea•mom ranrus-� FB01 (Floor Beam) BC CALC®Member Report Dry 11 span I No cant. March 16,2023 11:10:49 Build 16959 Job name: File name: 4 Runestone Address: 4 Runestone Road Description: ceiling beam City, State, Zip: S.Yarmouth, MA Specifier: Customer: Designer: Donald Spears Code reports: ESR-1040 Company: Cape Cod Lumber Connection Diagram: Full Length of Member a minimum= 1-1/2" c=6-1/2" b minimum=6" d=24" e minimum= 1" Calculated Side Load=0.0 lb/ft Connectors are: SDW22634 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement(EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call(800)232-0788 before installation. BC CALC®,BC FRAMER®,AJST"", ALLJOIST®,BC RIM BOARD TM,BCI®, BOISE GLULAMT"',BC FloorValue®, VERSA-LAM®,VERSA-RIM PLUS®, Page 2 of 2 t ,fE B U , • z , 71 i 1