Loading...
HomeMy WebLinkAboutUntitled -b dFi,r)r) I A, atrva/ s7 Y ma, " ? tt . Coo.) Y.es1cJ Fidab I, i ) Pw N) .t 1 -- ' 1/i/ ptio42 , -/ A-pAJAil; ../ / (, kz.frfis -kto . Pi .; ._„„mrial,L e -i- --Lo ieV-Z,r4 -,' ./Z / -e G 7y fiG14--i Iv 1-1/1' i''Pg-6 i * eS Wo.d• .', iht: ,:.. . . . GUILT" BUILD! FICIAL pJK,til plans V �3\ VM °(-)3 q;b illZZ4' 2 i L..J 1\ ,/'f 1 ®BolseCascade D W000D�TS • Double 1-3/4" x 11-7/8" VERSA-LAM® LVL 2.1E 3100 SP I PAi='5ED ENGRB01 (Roof Flush Beam) BC CALC®Member Report Dry I 1 span I No cant. April 19,2023 13:41:28 Build 16959 Job name: Flynn File name: Hudson-Flynn Address: 1A Walnut Street Description: City, State,Zip: South Yarmouth, MA Specifier: Customer: Jim Hudson Designer: Kevin Lonkart Code reports: ESR-1040 Company: Mid Cape Home Centers �0 12 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 /( B1 14-00-00 B2 Total Horizontal Product Length=14-00-00 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1,3-1/2" 1239/0 2310/0 B2,3-1/2" 1239/0 2310/0 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self-Weight Unf. Lin.(lb/ft) L 00-00-00 14-00-00 Top 12 00-00-00 1 Roof Unf.Area(Ib/ft2) L 00-00-00 14-00-00 Back 15 30 11-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 11622 ft-lbs 47.5% 115% 4 07-00-00 End Shear 2900 lbs 31.9% 115% 4 01-03-06 Total Load Deflection L/402(0.405") 44.8% n\a 4 07-00-00 Live Load Deflection L/617(0.263") 38.9% n\a 5 07-00-00 Max Defl. 0.405" 40.5% n\a 4 07-00-00 Span/Depth 13.7 Allow %Allow Bearing Supports Dim.(LxW) Value Support Member Material B1 Column 3-1/2"x 3-1/2" 3549 lbs n\a 38.6% Unspecified B2 Column 3-1/2"x 3-1/2" 3549 lbs n\a 38.6% Unspecified Cautions For roof members with slope(1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope(1/2)/12 or less final design must account for Rain-on-Snow surcharge load. Notes Design meets Code minimum(L/180)Total load deflection criteria. Design meets Code minimum (L/240)Live load deflection criteria. Design meets arbitrary(1")Maximum Total load deflection criteria. Design based on Dry Service Condition. BC CALC®analysis is based on IBC 2009. Calculations assume member is fully braced. Page 1 of 2 ®Boise - Double 1-3/4" x 11-7/8" VERSA-LAM® LVL 2.1E 3100 SP PASSED l ENGINEERED WOOD PRODUCTS RB01 (Roof Flush Beam) BC CALC®Member Report Dry 11 span I No cant. April 19,2023 13:41:28, Build 16959 Job name: Flynn File name: Hudson-Flynn Address: 1A Walnut Street Description: City,State,Zip: South Yarmouth, MA Specifier: Customer: Jim Hudson Designer: Kevin Lonkart Code reports: ESR-1040 Company: Mid Cape Home Centers Connection Diagram: Full Length of Member • • • T c e l� a minimum= 1-3/4" c=8-3/8" b minimum=6" d=24" e minimum= 1" Calculated Side Load =247.5 lb/ft All FastenMaster screws may be installed from one side of multiply Versa-Lam beams. Connectors are: FMFL312 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement(EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call(800)232-0788 before installation. BC CALC®,BC FRAMER®,AJSTM ALLJOIST®,BC RIM BOARDTM,BCI®, BOISE GLULAMTM,BC FloorValue®, VERSA-LAM®,VERSA-RIM PLUS®, Page 2 of 2