Loading...
HomeMy WebLinkAboutENERGY CODE INSPECTION CHECKLIST Energy Code Inspection Checklist Property Organization Inspection Status 33 Timber.Shaw Rd Home Energy Raters 2023-04-06 YarannewidIVIESIS Paul Graney Rater ID (RTIN): 2649950 RESNET Registered Thatcher Shore Rd 33 -B260KNVd Builder (Confirmed) Thacher Shore Road 33 final Jim Basler r— Name: >garage(18 s.f.) I_ U: 0.140 Glazing ri Name: Front dh (128 s.f.), U: 0.300, SHGC:0.28, Orientation: EAST I Name: Front shaded dh (33 s.f.), U: 0.300, SHGC: 0.28, Orientation: EAST Li Name: Front awning(5.4 s.f.), U: 0.290, SHGC: 0.29, Orientation: EAST E Name: Front fixed (5.7 s.f.), U: 0.300, SHGC: 0.32, Orientation: EAST —'' Name: Front gable awning (5.4 s.f.), U:0.290, SHGC:0.29, Orientation: EAST Name: Front gables fixed(9.7 s.f.), U: 0.300, SHGC: 0.32, Orientation: EAST El Name: Right dh (96.4 s.f.), U: 0.300, SHGC: 0.28, Orientation: NORTH Name: Right shaded dh (13.8 s.f.), U: 0.300, SHGC: 0.28, Orientation: NORTH Li Name: Right awning (5.4 s.f.), U: 0.290, SHGC: 0.29, Orientation: NORTH Name: Right fixed (5.7 s.f.), U: 0.300, SHGC: 0.32, Orientation: NORTH ' Name: Right gable awning (5.4 s.f.), U:0.290, SHGC:0.29, Orientation: NORTH Name: Right gable fixed (5.7 s.f.), U:0.300, SHGC: 0.32, Orientation: NORTH ri Name: Rear dh (120.2 s.f.), U: 0.300, SHGC: 0.28, Orientation:WEST • E Name: Rear fixed (10.5 s.f.), U: 0.300, SHGC: 0.32, Orientation:WEST t�t Name: Rear awning (15.7 s.f.), U:0.290, SHGC: 0.29, Orientation:WEST �—1 3 D Name: Rear gable awning(5.4 s.f.), U:0.290, SHGC: 0.29, Orientation:WEST RESNET COVID-19 REMOTE INSPECTION HOME ENERGY RATING Standard Disclosure For home(s) located at: 33 Thacher Shore Rd, Yarmouth, MA Check the applicable disclosure(s): fae1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: IA. Mechanical system design E. B. Moisture control or indoor air quality consulting WIC. Performance testing and/or commissioning other than required for the rating itself I I D. Training for sales or construction personnel E. Other(specify) lie3. The Rater or the Rater's employer is: F._ A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home 'i C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home Se4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products Installed in this home by OR is in the business of HVAC systems riRater :IW !Employer I_iRater Employer Thermal insulation systems Rater I—Employer I ,Rater EEmployer Air sealing of envelope or duct systems Rater nEmployer DRater 100tEmployer Energy efficient appliances nRater nEmployer iRater nEmployer Construction(builder,developer, construction contractor, etc) I IRater j Employer flRater LIEmployer Other(specify): �N.E.A.B. Rater r Employer nRater DEmployer ie5. This home has been verified under the provisions of Chapter 6, Section 603"Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). Rater Certification#: 2649950 6. This home has been verified using RESNET's COVID-19 interim remote verification protocols. https://www.resnet.us/about/us/resnet-covid-1 9-updates/ To report any complaints regarding this Rater's service, please visit: http://www.energyratersma.com/Feedback_New.html Name: Paul Graney Signature: Pad Glanel Organization: Home Energy Raters Digitally signed: 4/20/23 at 10:19 AM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 102.1.4.6 of the standard and are posted at https://standards.resnet.us The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Energy Code Inspection Checklist Property Organization Inspection Status 33 Thacher Shore Rd Home Energy Raters 2023-04-06 Yarmouth, MA 02675 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered Thatcher Shore Rd 33-B260KNVd Builder (Confirmed) Thacher Shore Road 33 final Jim Basler I Name: Rear gable fixed (9.7 s.f.), U:0.300, SHGC: 0.32, Orientation:WEST Name: Left dh (18 s.f.), U: 0.300, SHGC: 0.28, Orientation: SOUTH r- Name: Left awning/case (24.5 s.f.), U: 0.290, SHGC:0.29, Orientation: SOUTH I .J Name: Left awnings 2nd fl(5.4 s.f.), U: 0.290, SHGC: 0.29, Orientation: SOUTH r*tt Name: Left fixed (5.7 s.f.), U: 0.300, SHGC: 0.32, Orientation: SOUTH a___1 T. 1 Name:Left gable fixed (3.1 s.f.), U: 0.300, SHGC: 0.32, Orientation: SOUTH Skylight None Present Mechanical Ventilation 1..1. Mechanical ventilation system rated for,and capable of, providing continuous ventilation. _...+ System shall include automatic timing controls. System type: ERV, 24 hrs/day, 102 Watts Mechanical Equipment Boiler• Natural Gas • 100% Heating Load @ 95 AFUE Water Heater• Natural Gas• 100%Hot Water Load @ 0.83 Energy Factor Air Leakage Control Test Status: Blower-door tested House is air-sealed as to achieve 1,160 CFM50(1.01 ACH50)or less at final blower-door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 4 2018 IECC Infiltration limit for the design home is 3 ACH50. 2021 IECC Infiltration limit for the design home is 5 ACH50. Energy Code Inspection Checklist Property Organization Inspection Status 33 Thacher Shore Rd Home Energy Raters 2023-04-06 Yarmouth, MA 02675 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered Thatcher Shore Rd 33 -B260KNVd Builder (Confirmed) Thacher Shore Road 33 final Jim Basler General Building Information Conditioned Area (sq ft) 5,309 Conditioned Volume (cubic ft) 69,193 Insulated Shell Area (sq ft) 14,713 The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab None Present Framed Floor t Name: >basement(2,768 s.f.) 4-44 R-0 continuous insulation, R-30 cavity insulation Insulation Grade: II 4- r Name: >garage(781 s.f.) _,.� R-0 continuous insulation, R-29.97 cavity insulation Insulation Grade: II '__ Name:>basement stairs(57 s.f.) 4 R-0 continuous insulation, R-30 cavity insulation Insulation Grade: II Foundation Wall None Present Above Grade Wall r Name: >ambient(3,695 s.f.) 4_._4 R-0 continuous insulation, R-21.95 cavity insulation Insulation Grade: I r.1 Name:2nd fl kneewalls (501 s.f.) R-0 continuous insulation, R-22.75 cavity insulation Insulation Grade: I 1 Energy Code Inspection Checklist Property Organization Inspection Status 33 Thacher Shore Rd Home Energy Raters 2023-04-06 Yarmouth, MA 02675 Paul Graney Rater ID (RTIN): 2649950 RESNET Registered Thatcher Shore Rd 33-B260KNVd Builder (Confirmed) Thacher Shore Road 33 final Jim Basler '- Name:gable (1,012 s.f.) 4-_ R-0 continuous insulation, R-19.5 cavity insulation Insulation Grade: I tName: >basement stairs(136 s.f.) R-0 continuous insulation, R-15.05 cavity insulation Insulation Grade: I EName: >garage(180 s.f.) R-0 continuous insulation, R-21.95 cavity insulation Insulation Grade: I Rim Joist e = Name: >ambient(165 s.f.) R: 20.00 Ceiling ! Roof _1 Name: Finished Slopes (902 s.f.) - R-0 continuous insulation. R-34.3 cavity insulation Insulation Grade: I [-? Name: Unfinished Slopes (4,516 s.f.) • R-3.7 continuous insulation, R-36.15 cavity insulation Insulation Grade: I Opaque Door Name: Front(40 s.f.) U: 0.201 fLL_1 Name: Rear(36 s.f.) :-__.., U:0.223 Name: Left(18 s.f.) U:0.168 Name: >basement(17 s.f.) 2 - !! U: 0.526 Energy Code Inspection Checklist Property Organization Inspection Status 33 Thacher Shore Rd Home Energy Raters 2023-04-06 Yarmouth, MA 02675 Paul Graney Rater ID(RTIN): 2649950 RESNET Registered Thatcher Shore Rd 33 -B260KNVd Builder (Confirmed) Thacher Shore Road 33 final Jim Basler Duct Leakage Duct System 1 NOT entirely within conditioned space,testing required Leakage to Outside specified as: 56 CFM @ 25Pa(2.03 /100 ft2) Total Leakage specified as: 56 CFM @ 25Pa (Rough-In, with Air Handler) Duct System 2 NOT entirely within conditioned space,testing required Leakage to Outside specified as: 10 CFM @ 25Pa(0.39/100 ft2) Total Leakage specified as: 56 CFM @ 25Pa (Rough-In,with Air Handler) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors<= 8 CFM25/ 100 sq ft CFA. Rough in Test with AHU:Total Duct Leakage <= 6 CFM25/100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <=4 CFM25/100 sq ft CFA. 2012 IECC Mandatory, 2015, 2018, &2021 IECC Prescriptive Paths: Postconstruction Leakage Test:Total Duct Leakage<=4 CFM25/ 100 sq ft CFA. Rough in Test with AHU:Total Duct Leakage<=4 CFM25/100 sq ft CFA. Rough in Test without AHU:Total Duct Leakage <=3 CFM25/100 sq ft CFA. Note: IECC 2021 requires Total Duct Leakage<= 8 CFM25/100 sq ft CFA when all ducts and air handlers are within the building thermal envelope. 2015 and 2018 IECC Performance Paths(Cost Compliance): Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes Errors and Warnings have been Rater Reviewed 5 Air Leakage Report Property Organization Inspection Status 33 Thacher Shore Rd Home Energy Raters 2023-04-06 Yarmouth, MA 02675 Paul Graney Rater ID(RTIN): 2649950 RESNET Registered Thatcher Shore Rd 33-B260KNVd Builder (Confirmed) Thacher Shore Road 33 final Jim Basler General Information Conditioned Floor Area [ft2) 5,309 Infiltration Volume[ft') 69,193 Number of Bedrooms 4 Air Leakage Measured Infiltration 1160 CFM50(1.01 ACH50) ACH50 (Calculated) 1.01 ELA[sq. in.](Calculated) 63.64 ELA per 100 s.f. Shell Area(Calculated) 0.433 CFM50 (Calculated) 1,160 CFM50/s.f. Shell Area (Calculated) 0.079 Duct Leakage System 1 System 2 Leakage to Outdoors 56 CFM @ 25Pa 10 CFM @ 25Pa (2.03/ 100 ft2) (0.39/ 100 ft2) Total Leakage Test Type Rough-In,with Air Rough-In,with Air Handler Handler Total Leakage [CFM @ 25 Pa] 56.0 58.0 Total Leakage[CFM25/ 100 s.f.] 2.0 2.3 Total Leakage [CFM25/CFA] 0.020 0.023 Mechanical Ventilation Rate[CFM] 140 CFM Hours per day 24.0 Fan Power 102 Watts Recovery Efficiency% 70.0 Runs at least once every 3 hrs? true Average Rate [CFM] 140.0 CFM 2010 ASHRAE 62.2 Req. Cont.Ventilation 90.6 2013 ASHRAE 62.2 Req. Cont.Ventilation 139.1 Ekotrope RATER-Version 4.0.2.3141 All results are based on data entered by Ekotrope users.Ekotrope disclaims all liability for the rteformation shown on this report. Energy Specifications Label 33 Thacher Shore Rd Ekotrope RATER-Version: 4.0.2.3141 HERS®Index Score: 55 Building Envelope Specs Ceiling: R-40 Above Grade Walls: R-22 Foundation Walls: N/A Exposed Floor: R-30 Slab: N/A Infiltration: 1160 CFM50 (1.01 ACH50) Duct Insulation: Supply: R6, Return: R6 Duct Lkg to Outdoors: 56 CFM @ 25Pa(2.03/ 100 ft2) Window& Door Specs U-Value: 0.3, SHGC: 0.28 Door: R-5 Mechanical Equipment Specs Heating: Boiler • Natural Gas•95 AFUE Cooling: N_A Hot Water: Residential Water Heater• Natural Gas •0.83 Energy Factor Average Mechanical Ventilation: 140 CFM Builder or Design Professional Signature: Home Energy Rating Certificate Rating Date: 2023-04-06 Final Report Registry ID: 109500840 Ekotrope ID: B260KNVd HERS" Index Score: Annual Savings Home: 55 Your home's HERS score is a relative 33 Thacker Shore Rd performance score.The lower the 1E199 Yarmouth,MA 02675 number, the more energy efficient the Builder: home.To learn more,visit "Relative to an average US.home Jim Basler Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 97.6 $2,335 2018 International Energy Conservation Code Cooling 0.0 $0 2015 International Energy Conservation Code Hot Water 11.0 $261 2012 International Energy Conservation Code Lights/Appliances 34.9 $2,971 2009 International Energy Conservation Code Service Charges $0 2006 International Energy Conservation Code Generation(e.g.Solar) 0.0 $0 Total: 143.5 $5,567 HERS Index Home Feature Summary: Rating Completed by: More 2none Home Type: Single family detached Model: N/A Energy Rater. Paul Graney Existing 140 Community: N/A RESNET ID: 2649950 Homes 230 Conditioned Floor Area: 5,309 ft2 Rating Company: Home Energy Raters tm Number of Bedrooms: 4 180 State Rd,Suite 2U Sagamore Beach MA 02562 Reference 2 Primary Heating System: Boiler•Natural Gas•95 AFUE 508-833-3100 Home 100Primary Cooling System: N_A 90 Residential Water Heater•Natural Gas•0.83 Energy Rating Provider: Energy Raters of Massachusetts go Primary Water Heating: Factor 2 Woodlawn Street Amesbury,MA 01913 TO House Tightness: 1160CFM50(1.01 ACH50) 978 270 3911 �, • °_.,,� so_ 55 Ventilation: 140 CFM•102 Watts•ERV ao This Home Duct Leakage to Outside: 56 CFM @ 25Pa(2.03/100 ft2) , ,,.,„.>„ 30 Above Grade Walls R-22 20 Ceiling: Vaulted Roof,R-40 l Pau " ey Zero Energy u Window Type: U-Value:0.3,SHGC:0.28ome Paul Foundation Walls: N/A Paul Grapey,Certified Energy Rater `essEm� Framed Floor. R-30 Digitally signed:4/20/23 at 10:19 AM ii, ekotrope Ekotrope RATER-Version:4.0.23141 • The Energy Rating Disclosure for this home is available from the Approved Rating Provider. Energy savings calculated without modifications to the energy model.(As Modeled) This report does not constitute any warranty or guarantee.