No preview available
HomeMy WebLinkAboutBLD-23-005945 RECEIVED APR 26 2023 BUILDING DEPARTMENT(.° ";_ try .� /J /jore cauz.chi,i.oz onAfrediaa../5 ke - o ad . a 1146 Route 28, S gi&02664 APPLICATION FOR FIRE PROTECTION PERMIT Date 1//7_6 7 PERMIT NUMBER tSu)-2 3 ' L/ Projected Start Date: 7L0/7_- Date of issue In accordance with the provisions of 780 CMR and M.G.L. Chapter 148, as provided in Section This application is hereby made 1 % , � j � ��C y /} ,�; (Full name of person,Firm or Cor oration) Address /z cs,- /Coy-�,/C; �v�. ktn'' COY--; /t i,�7 (Contact#) 0599 mail -tilt� �e c�S�c`G -(u13''it5 Owner of property £L7'- aros,_ l Job Location C2/44 ,'%--o c cJ -/ f 6't (X.L'- (Street&City or Town) For permission to (state clearly purpose for which permit is requested) / /;-7/ -8e_. -6rec Gles_rwk f/0-- - Name of competent operator(if applicable) /Q3 r✓e-r/- Cert. or Licens No. / / 7 C- Estimated Cost of Construction: I Z By .ig�atlir of�lppli ntj Buildin Official: Date: J\. 3 FEE: $50.00 r + � £SAS c; 51q A fi • • sf ii.;• ..,�, • • - � I ( /�,� I : DOI a jai)) 41/4. � Inc. 1265 Route 28 • South Yarmouth, MA 02664 • 508-394-0599 • MA LIC. #1317C 24 HOUR PROTECTION April 25, 2023 Yarmouth Building and Fire Departments 1146 Route 28 Yarmouth, MA 02664 Alarm Narrative—Nauset Disposal—Office Building 61 Commonwealth Ave. South Yarmouth, MA Manager: Tim Delude, 508-958-2222 Description - This is an existing wood framed two story structure that has reopened under new ownership for the continued use as office space for a trucking/disposal company. There is no basement and the total square footage on the two stories is 3450sqft. The building is not sprinkled. Code Requirements—MA Building code designates the use group as B and does not require a fire alarm system for the use group. There are no special considerations that would require protection, supervision, or control functions provided by a fire alarm system. Design Objective—The owner would like to install a voluntary system for the primary purpose of property protection. Horn/strobes will be placed throughout for life safety notification. System Components & Installation- The fire system will consist of a conventional Napco Firewolf 8 zone fire alarm control panel (FACP) with 24 hour battery back-up. A fire listed cellular radio will provide sole path or backup communications. The FACP will be located in the electrical room with a keypad annunciator by the front door. Fire detection and notification appliances will be installed per the submitted plan. Field modifications for locations and device types may be required. As-builts will be provided on completion to reflect any changes. The system will meet 2013 NFPA 72 standards except regarding detector spacing per 17.5.3.3 All devices and wiring will be listed and approved and comply with 527 CMR-12.00. Bathrooms and public spaces will have strobe lights per ADA and 521 CMR requirements. Manual pull stations will be located at the 3 first floor exits. Operation - Upon a general fire alarm the horns will pulse a temporal 3 evacuation tone and the strobe lights will flash. Our UL listed Central Station will be notified via the landline or cellular communicator. The alarm will then be retransmitted to the Cotuit fire department specifying the zone in alarm. Silencing and reset are done at the keypad annunciator with a code number. Trouble conditions will tone at the annunciator and be transmitted for caretaker response. Seaside Alarms will perform a 100%operational test and provided the required NFPA record of completion, UL certificates, as-built,battery calculations, etc. at the final inspection. Monitoring and service— Seaside Alarms will provide monitoring by our UL listed central station. Test signals will be sent to central station by the cellular and/or landline communicators to ensure operation and a signal path. Sole path communications will have an hourly test signal dual path phone and cell will test every 6 hours. Seaside Alarms will provide routine service, inspections, and emergency repairs for this system. 9' I Mi I1 to-�V r c� g __ _ O0 In es 0 O - .4 v .., „cp......, b ;,:;' N 2 d to -1—f2. 162* T Isg "a ` rr f ■ ■N • r b p Q `i p •1 :• Z 11¢ � at 0a O O i Z A Y r n:■ 111 4' ri 0 iE g ci, Vk * [l - r I. C.a i oc u w = b I 1 38 ,....4..„vr. cty,_..- i fit imam `C3 -1: I__ ■ ^ it —cr t =ER t-r), cn 1'6' S R,, L.1 3 64- CDa (71.1) 9' 0,. _ N 2'4.,+1-4.4..N .cl j I b " L CD o c. _ -. a 1 �3' • r t ,,. U _ _ \1v CO 7 ^ - a. y ^Z i 0 7Jcn -O y5 4 1.:. t a��'' 1 • • , _ a O y 7�� S CD - 1 �O LN : floi ,d4 ,.„ . ,c .....„. 4.--.--diN 1 [I 2 . It �Q- . CD • i` • ' ' CD ___ - St • d •� It j Sv 1. - C ♦ 'u CAD I • ` J+ X ^ x 0 '-A _ 41 cc- 4l • • 1 15'2" --+-3'4"-1--—11.6" I -6' 2" I 9' �Li 11' 4" �— "T:016: '1'8' 8" . ,_s, 111 1111 I� ., % T iK„, � • — /--4� 4,� � _ ���'" If you want guest �- p t�— seating In front of :- \Undei _ edOffi , Con�ro,ter Office _ N this h I— "± I _ O 1 ' ^ p edema under window 4 4 Hallway - P II I-3' 8'1-Mechanical ,y. 8 s. , IC,r. C , .�71 - 0"' I 12' 2" . 11' 4 8' --li '7 i" \• 7/ Fn . ) / N T --,.„ 14' 2„ �� NIP HTr, alf Bath / • - Ail v-, , iO 11 � • 3' 6" _ sic - - 5ii - - ziali7 - - 11' 10" i �tl 1�_ ,1 1�: .SI District g __--::___ • ���III,,, 1 IF VII . 7 _ [ onfere l;►e Room7 ICII ^ 1 41 oc ,- ;.ales Office I [17n JLL_ 1 13' 1 14' 6" I 12' 2 �. ,t e- 2' can put against wall � G`��" If you want a larger table K`.A7'CET FT Q' Proposed 2nd Floor ACo CERTIFICATE OF LIABILITY INSURANCE DATE IYYYY) 02/23/2023/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER-THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Emily Montgomery NAME: The Hilb Group New England.LLC PHONN Exq: (800)640-1620 dba Dowling&O'Neil E-MAIL emontgomery@hilbgroup.com ADDRESS: 973 lyannough Road INSURERS)AFFORDING COVERAGE NAIL# Hyannis MA 02601 INSURER A: Crum&Forster Specialty Ins 44520 INSURED INSURER B Safety Indemnity Insurance Co 33618 Seaside Alarms,Inc. INSURER C: Hartford Fire Insurance Co 19682 1265 Route 28 INSURER D: INSURER E: South Yarmouth MA 02664 INSURER F: COVERAGES CERTIFICATE NUMBER: CL2322138979 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL I:• POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSO wVD POLICY NUMBER (MM/DD/YYYY) (MMIDO/YTTY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE I C.)CLAIMS-MADEX OCCUR PREMISES c ES(Ea coaarence) $ 50,000 MED EXP(Any one person) S 5,000 A GL0095222 02/25/2023 02/25/2024 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY X PERa LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: PROFESSIONAL LIAB s 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000.000 (Ea accident) ANY AUTO BODILY INJURY(Per person) $ g OWNED X SCHEDULED 622210710 02/25/2023 02/25/2024 BODILY INJURY(Per accident) $ _ AUTOS ONLY _. AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY X AUTOS ONLY (Per accident) UMBRELLA UAB OCCUR EACH OCCURRENCE $ 1,000,000 A X EXCESSuae CLAIMS-MADE SE0122668 02/25/2023 02/25/2024 AGGREGATE $ 1,000,000 DED 1 RETENTION$ WORKERS COMPENSATION vI PER OTH- AND EMPLOYERS'LIABILITY Y/N �I STATUTE ER C ANY PROPRIETOR/PARTNER/EXECUTIVE N N/A 08WECAE7ZU7 02/25/2023 02/25/2024 E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Insurance coverage is limited to the terms,conditions,exclusions,otherlimitations and endorsements Nothing contained in the certificate ofinsurance shall be deemed to have altered,waived.or extended thecoverage provided by the policy provisions. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Yarmouth ACCORDANCE WITH THE POLICY PROVISIONS. 1146 Route 28 AUTHORIZED REPRESENTATIVE South Yarmouth MA 02664 - --•0`'"1,'` :3=Taavain ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts !f, Department of Industrial Accidents 11115."" � 1 Congress Street,Suite 100 7411= Boston,MA 02114-2017 „07, www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): Seaside Alarms Inc Address: 1265 Route 28 City/State/Zip: South Yarmouth, MA 02664 Phone#: 508-394-0599 Are you as employer?Check the appropriate box: Type of project(required): I.�✓ 1 am a employer with 1 9 employees(full and/or part-time).* 7. New construction 2.0 I am a sole proprietor or partnership and have no employees working for me in 8. Remodeling any capacity.[No workers'comp.insurance required.] 3.01 am a homeowner doingall work myself 9. Demolition❑ y [No workers'comp.insurance required.] 10 Q Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 1 1.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. These sub-contractors have employees and have workers'comp.insurance.: 13.�Roof repairs 14. Other Security&Fire Alarm 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 152,*1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees.they must provide their workers'comp.policy number. I an:an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Hartford Fire Insurance Co. Policy#or Self-ins.Lic.#: 08WECAE7ZU7 Expiration Date: 2/25/24 Job Site Address: All site in y� ?rL� City/State/Zip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: r� t'ki 5,4)f A Date: d--4-7 Ja-3 Phone#: 508-394-0599 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Commonwealth of Massachusetts i COMMONWEALTH OF MASSACHUSETTS irDivision of Occupational Licensure DIVISION OF OCCUPATIONAL LICENSURE . BOARD OF '+ i►c• ELECTRICIANS SecuritZ stem cense yLi ISSUES THE FOLLOWING LICENSE SSCO-000046cpires: 01(05/2025 REGISTERED SYSTEM CONTRACTOR ROBERT BOUCH'E? • .`� z ROBERT K BOUCHER ° Empl6yyed by: y a SEASIDE 4ARMS INC �e 1265 ROUTE 28 �� S YARMOUTH,MA 02664-4455 N3 1 �tor.L4d:1- , V A.7., Commissioner da164K. StmiltA, 1317 C 07/31/2025 291777 LICENSE NUMBER EXPIRATION DATE SERIAL NUMBER it COMMONWEALTH OF MASSACHUS S 0 COMMONWEALTH OF MASSACHUSETTS DIVISION OF OCCUPATIONAL LICENSURE DIVISION OF OCCUPATIONAL LICENSURE BOARD OF BOARD OF ELECTRICIANS ELECTRICIANS \1 ISSUES THE FOLLOWING LICENSE w ISSUES THE FOLLOWING LICENSE REG t REGISTERED SYSTEM TECHNICIAN SYSTEMS CONTRACTOR BUSINESS •> ROBERT K BOUCHER < ° SEASIDE ALARMS INC :,4 1265 ROUTE 28 w w 1265 ROUTE 28 S YARMOUTH,MA 02664 • •55 z S YARMOUTH,MA 02664-4455 1 4.j'7 -max 463 D 07/3112025 291784 4177 C1 07/31/2025 391646 LICENSE NUMBER EXPIRATION DATE SERIAL NUMBER LICENSE NUMBER EXPIRATION DATE SERIAL NUMBER f SYSTEM SENSOR 4 4 Photoelectric Smoke Detectors System Sensor i3""series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide angle,dual color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature -Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings m 4> MEA MSFNI LISTED .gyp i i approved approved "$ S911 3011446 7272-1653:152 290-01-E 2093 3180932 1j)Smoke Detector Specifications - • ( .'n ing .- ation Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 25 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum:35V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 NA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.596/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM 02009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product ,6�ti« subject to a, „,n«r notice , a SENSOR Phone:Boo SENSOR2•Fax:630 377 649$ cu"entpradiGinformation, ud1io the latest YAS'"'°this data sheet A05-0318-007.6/09•#2169 Napco CommercialTM Firewolf-Series Components for 32 to 255 Point 24V Commercial Fire Systems: SYSTEM Advantages •Easy Wire Compatibility-Addressable SLC •Main Control board supports up to two(2)Addressable Fire SLCs controller supports shielded,unshielded, (addressable Signaling Line Circuit controllers).(Note:Only 1 SLC is twisted and untwisted wire-ideal for retrofits accomodated within the Medium panel enclosure.*) •Longer SLC loop lengths,support more c••••••• 9 •Fire 4-wire bus for keypads and non-SLC(conventional)devices, eii '••••,• Yp device loads each,too(see below for rmt....,,,,(11 including 12V devices distance at maximum device load in alarm/ •Power Supply includes either 4A or 7A CO 24V standby each): •RS-232 Printer Module for optional onsite parallel printer • 10,000 ft.#14AWG•6,200 ft.#16AWG • •Supports up to 7 fire keypads,GEMC-FK1,mounted anywhere on the 4,000 ft.#18AWG bus.(As few as one keypad required on system for equipment savings.) •Support for Legacy and Existing Notification Appliances-One NAC • Easy-to-use Gemini-style menu-driven operation with backlit custom output configurable for 12V for easy retrofit compatibility alphanumeric display and functionality for •UL Regulated NAC outputs Reset,Acknowledge,Silence(with disable). •Automatic drift compensation for SLC smoke detectors • Full Keyswitch Support •Keypads mount anywhere on the bus and have flash-able firmware- •Synch module built in on each NAC (System Sensor&Wheelock for updates via Quickloader command(#GEMC-FK1,shown above) protocols) •Programmable obscuration level by smoke detector device •Dual Phone Line built in •Smoke Obscuration Report genererated remotely or locally or in any • 2 On board serial ports-one for internet reporting;one for of 3 ways-Quickloader device sensitivity report allows the printout of high-speed local downloading a report for the AHJ listing the current status of all smoke detectors •TCP/IP Internet reporting module in the system including the programmed obscuration level and the •Regulated Auxiliary Power Supply-Commercial fire, actual sensitivity reading for each device.This report can be generated 12V regulated 2A remotely(uploaded)or locally through notebook PC or use optional •Addressable SLC Loop Isolator(optional use-for some fire onsite printer. applications requiring increased circuit integrity,e.g.,meets Class A, •Full line of UL Commercial Devices for more flexibility&labor-savings Style 7 loop requirements. Example,Use Gemini Commercial Wireless 2-input module(GEMC- •Choice of two enclosures -Between the studs enclosures,recess or WL-WD2)to convert any UL listed fire device into a UL wireless device, surface mount - ideal for sprinkler supervisories or for use with pull stations(mounts on • Larger version supports up to 32 AH at 24V. Dimensions:24"x top of wall/conduit or in deep sngle-gang box(plastic). 14.25"x 5.2"(H x W x D)without cover.Removable battery shelves, •Separate 7Amp 4-NAC Extender(GEM-NAC7)4 onboard NACs with accommodate pairs of 7Ah,7.5Ah and 8Ah batteries,etc. up to 2A ea.,expandable for up to 24 per system.Up to 28Ah total •Medium Enclosure-supports 16 AH at 24V.Dimensions: 16"x battery capacity.Regulated 24V Aux.power.Monitors AC,battery 14.25"x 5.2"(H x W x D)without cover.(*Note:Only 1 SLC is trouble,tamper and ground fault on Napco bus-Also Provides accomodated.)16Ah battery backup capacity. Universal FACP support for easy standardization in upgrades INPUTS Up to 255 Zones.Zones can come from any of the following initiating devices: .. I •Addressable SLC Loop-supports up to(2)126 point loops •Commercial RF Receiver- 4 . ... • ' e •Supports Commercial Wireless Fire devices 4 ' •Wireless Smoke Detector Model GEMC-WL-SMK f � 74 •Wireless Heat Detector Model GEMC-WL-HEAT -' •Wireless contact transmitter(for waterflow,tamper,pull stations, . s etc.)Model GEMC-WL-WD2. 0 I •Conventional 1-to 4-zone EZM Expansion modules on the 4-wire fire e bus or SLC loops , . r. w •Conventional 2-wire or 4-wire smoke detector input module ' - •. •SLC Fire Devices Supported: •Analog Smoke Detector •Analog Heat Detector a •Duct Detector •Pull Station •Conventional Zone Module •Short Circuit Isolator .! OUTPUTS Up to 96 outputs (Shown above) •Four on board Class B or 2 Class A NAC circuits,2 amps each,total 6.5 32-Point GEM-C FirewolfrM 24V Commercial Fire System amps at 24V •Built in Wheelock and System Sensor NAC sync/strobe/horn protocol Agencies allows initial silence of audible appliances while maintaining visual NFPA 72,UL Commercial Fire,UL864 9th Ed.,UL985,CSFM and notification,without the use of additional modules. NYC Fire Department Certifications. •Addressable SLC Fire Devices:Supervised relay,unsupervised relay •Fire 4-wire bus devices:8 zone form C relay(GEMC-RM3008),8 open collector output(GEMC-OUTS) NAPCO COMMERCIAL FIREWOLF SERIES SYSTEM ORDERING INFO. Napco Commercial Fire)f; GEMC-FW-255KT 255 Point GEM-C Firewolf.24V Commercial Fire System Kit •24V Panel,255 Points via commercial addressable,wireless or conventional fire devices,4 on board NACs providing up to 6.5A notification power •7 Amp,24V Power Supply •Built in horn/strobe synch.module on each NAC •Built in dual line communicator;dual onboard serial ports •Quickloader up/downloading including remote smoke obscuration reporting •Locking,Large Red Enclosure,16 x 25"reversible door,with 74.25"x 25"base.Houses up to 32Ah battery backup. •Menu-driven LCD Fire Keypad mounts anywhere on bus.(Also,full keyswitch support) GEMC-FW-128KT 128 Point GEM-C Firewolf 24V Commercial Fire System Kit As above,but with •24V Panel,128 Points via commercial addressable,wireless or conventional fire devices,4 on board NACs providing up to 6.5A notification power GEMC-FW-32KT 32 Point GEM-C Firewolf°'24V Commercial Fire System IGt Similar to above,but with •24V Panel,32 Points via commercial addressable,wireless or conventional fire devices,2 on board NACs providing up to 4A notification power • Locking,Medium Red Enclosure,16 x 17"door,with 14.25"x 16"base.Houses up to 16Ah battery backup. GEMC-FW32CONVKT 3 Point GEM-C Conventional Commercial Fire System Kit,ideal for sprinkler/waterflow apps.24V Panel,32 Points via commer- ci.l addressable,wireless or conventional fire devices,4 on board NACs providing up to 6.5A notification power •Locking,Medium Red Enclosure,16 x 17"door,with 14.25"x 16"base.Houses up to 16Ah battery backup. •4 Amp,24V Power Supply •Conventional 8-zone 2-wire fire input module,for conventional 2-wire smokes or any conventional fire detection device(GEMC- FBZCPIM) •Built in horn/strobe synch.module on each NAC •Built in dual line communicator;dual onboard serial ports •Quickloader up/downloading including remote smoke obscuration reporting(for addressable detectors) •Menu-driven LCD Fire Keypad mounts anywhere on bus(GEMC-FK1) Converei..n l Fire System Peripherals GEMC-FK1 LCD Fire Red Keypad(Menu-driven operation,functionality for Reset,Acknowledge,Silence(with disable). GEMC-F8ZCPIM Conventional 8-zone 2-wire fire input module.Plugs into motherboard,for conventional 2-wire smoke detectors or any conventional fire detection device. GEMC-EZM8 8-point Expansion Module GEMC-NL-MOD Internet Reporting Module Wireless Firewolf Peripherals GEMC-WL-SMK Gemini Commercial Wireless Smoke,Photoelectric(complete). GEMC-WL-HEAT Gemini Commercial Wireless Heat,135°F GEMC-WL-WD Gemini Comml Wireless slim profile 1-input wireless module GEMC-WL-WD2 Gemini Comml Wireless 2-input module converts any UL listed device into a UL wireless device(ex.,pull stations or sprinkler supervisories.) GEMC-REVC Gemini Commercial Wireless 255 point RF Receiver(up to 4 per system,max.) Addressable Firewolf Peripherals GEMC-FW-SLC Addressable SIC Fire Module,supports up to 128 addressable SLC fire devices,below.Up to 2 connect to Panel. FWC-FSLC-SMK Addressable Analog SIC Smoke,photoelectric,head** FWC-FSLC-HEAT Addressable Analog SLC Heat,135°F,head`" FWC-FSLC-DUCT Addressable SIC Duct smoke detector,photoelectric FWC-FSLC-DUCTRA Remote Indicator Plate with LED indicator&key reset. FWC-FSLC-EZM2 Addressable SIC 2-zone conventional expansion module.Uses one address on SLC loop,but yields 2 indep.contact monitoring circuits,for pull stations,water flow and other dry contact alarm initiating devices. FWC-FSLC-EZM1 Addressable SIC 1-input conventional module,similar to usage above. FWC-FSLC-CZM Addressable SIC single module,for montoring of dry contacts,ie.,pull stations and cony.smokes FWC-FSLC-RM2 Addressable SIC 2-output module(requires 1 SLC address) FWC-FSLC-ISO Addressable SIC Short Circuit Module(Optional:For special applications,meets Class A,Style 7 loop reqts.) FWC-FSLC-SOM1 Addressable SIC Fire supervised output module.Application examples:elevator recall,HVAC shutdown,add'I NAC output w/ power supply FWC-FSLC-PULL Addressable SIC Fire Pull Station,standard hex-key reset. FWC-FSLC-PULLK Version of above,with key reset. FWC-FSLC-PULL2 Dual action pull station,with hex-key reset. FWC-FSLC-PULL2K Dual action,with key reset. FWC-FSLC-PROG2 Tool for address-programming SLC devices FWC-FSLC-SMK6B "Smoke/Heat 6"Base,required for FWC-FSLC-SMK and—HEAT devices Output Options GEMC-NAC7S Remote 4-output NAC Extender,for 6.5A ttl,or 2A,max.on any 1 output.Red 14 x 16"can,connects to 120VAC,supports 24V 28Ah standby batty.Supervised,fire bus connection.System Sensor and Wheelock NAC synch.(5/system,for 20 add'l NAC circuits ttl.) GEMC-12V2APS-CF 12VDC Power Supply for Fre Bus,remote supervised.Direct 120VAC connection,supports 2ea.12V,7Ah to 18Ah standby batts. GEMC-FPRINT Parallel Printer Module GEMC-RM3008 8 Form C Relay Output Module GEMC-RS232 RS232 Adapter for serial output from Panel GEMC-OUT8 PGM Output Module,8 open collector PGM outputs rirA A NAPCO Security Technologies,Inc. www.napcosecurity.com swog 1-800-645-9445•631-842-9400 NAPCO Amityville,NY USA May 2011,Product specifications&availability subject to change without notice.©NAPCO A601 B v NAPCO I COMMERCIAL - FIREWOLF SYSTEM COMPONENTS FIREWOLF-SERIES LARGE ENCLOSURE(SHOWN) • AORT AMP MAIN POWER SUPPLY - M GOEMGPBZ.VTA.R°, FIRE BUS DEVICES • •{ I • MOTHERBOARD I GEMCfBZCPIM GEMCEZMB GEMCSECV 1, • 8 Fire Zone Expander CONVENTIONAL EW rv�n .. ZONE EXPANSION a « ` -•Iluruuuuuuu�ull MODULE E - -- - GEMC-OUTB M.MAX.1 S ZONE OUTPUT REMOTE RELAY b � F EIR C J I J I i MODULE ERMST RSPORTHEE ADDRESSABLE / , \� ))) I GEMC-WL-SMK • _ ......- woe. LOOP • - G -• - • VM al j 'a , FWC-F SLC SMK SAME EiROY SAME GENCFEISO/�: E<.r IIWOO�W�� SMOKE DETECTOR 02 T ►u JII�DIEI^ �IIOMN� II ZONES OF GENC•WLNEAT ++' ' NMS LJ� NOEN J->< CONVENTIONAL 2-WIRE SMOKES LJ` J_ PULL STATIONS AND/OR HEAT DETECTORS �i',•i 5u"^ s'- »%'.'- ♦II- M/_.... _* _ -, - STONE ,• E EI= ADDRESSABLE OBS HORN • • SMOKE •- . DETECTOR M pR MOM I • -• I U. EAT DETECTOR FWG-FSLC-HEAT I■ ..DN-BODED NAG anon(cuss SI SOWN) GEMC-WLWG7 NMN ICON NOM •`Of" GEMC-TMAPSCF _WEI.fro k �� ni, .zON.BOARO NAC WV SUPPOWERII!" &Am • • u., y J 1L�JL1 CIRCUITS(CUSS N SUPPLY MAVM SRMSF SOME ZONE ADDRESSABLE •-..., TRANSMITTER NEAT MRSSE WITH TAMPER DETECTOR EOU EOLR EOLR EOIA �nN- --MA,- t3K E.EK E.EK EN( EOM ECU' EOM3K J2^ �_�l � FWGFSLC-PULL ZAK SATE LEK 2.M( NORM ILL, I I�I� x 1L Jl'.1 1l Jl.'! NMN MRME NMN GE PRI TPRIN AoolrnAeLE •1 ON-BOARD NAC I D. ER M CIRCUITS(CLASS B( I C-FPR PULL STATOR Or (Also Hex and K•yal m My RAMO MO edic�0tl0A' ••2ON-BOARD NAC IpRx NOM I CIRCUITS(CLASS A) FEECFSLCDUCT (NOT SHOWN)II ��I LN 1m�EN LJ� aneeEE INMM NIERM i 1 1 STONE ;TEM E €STROME , DUCT DETECTOR \ / / RMaaANse ya l 1( I GEMC-NAC7 AM P NAC EXTENDER FWCFSLC.EZM12 ''x3i (S.MAX.) FWCFSLCF2M1 - DUAL INPUT FWC-FSLC.SOM1 FWCFSLC-RM2 MONITOR MODULE I INyy� FAST RESPONSE SUPERVOED DUAL RELAY MONITOR MODULE OUTPUT MODULE MODULE FWCFSLC.SMKSB OEMCFNI FWCFSLC-ISO FWCFSLC-CZM UP TO TEB F ��, DEVICES � 2 SLC MODULES,max. Note:The four GEMC-RECV max.ie reduced by 1 for each SLC module. SHORT CIISOLARCUIT OR ZONE O MODULE Ia-BABE ONLY) FRE KEYPAD