HomeMy WebLinkAbout453 Station Ave CVS plan 21I EXISTING PANELBOARD SCHEDULE ABBREVIATION LEGEND CONTRACTOR RESPONSIBILTIES EXISTING PANELBOARD C � " ii r MAINS ® 125 Ms FRI C17 Front bench i SCHEDULE (MODIFIED EXISTING) SURFACE Room o A /AMP AMPERE JB AC ALTERNATING CURRENT JB AFF ABOVE FINISH FLOOR KW AWG AMERICAN WIRE GAUGE LTG C CONDUIT MCB CB CIRCUIT BREAKER MLO CKT CIRCUIT NEC EF EXHAUST FAN RTU GFI GROUND FAULT CIRCUIT INTERRUPTER TELE GIRD GROUND TYP HP HORSEPOWER V IG ISOLATED GROUND VA DISC TRANSFORMER W DISC SW DISCONNECT SWITCH WP FU FUSE JUNCTION BOX KILOVOLT -AMPS KILOWATT LIGHTING MAIN CIRCUIT BREAKER MAIN LUGS ONLY NATIONAL ELECTRICAL CODE ROOFTOP UNIT TELEPHONE TYPICAL VOLT VOLT-AMPERE WATT WEATHERPROOF 1. THE LOW VOLTAGE COMMUNICATIONS LOOP SHOWN IN THE ELECTRICAL PLANS. THE ELECTRICAL CONTRACTOR SHALL INSTALL A #22TSP CABLE BETWEEN THE ROOFTOP UNITS AND THE ECT MAIN PANEL (EINSTEIN PANEL) AND ANY CONDUIT SHOWN ON THE ELECTRICAL DRAWINGS. 2. THE SIGNAL WIRE FOR THE MANAGER'S OVERRIDE BUTTON. THIS IS SHOWN ON THE ELECTRICAL PLANS. 3. THE LIGHTING CONTACTOR PANEL SHOWN IN THE ELECTRICAL PLANS. THIS IS PROVIDED BY ECT UNDER SEPARATE CONTRACT WITH THE JOB ELECTRICAL CERTAIN THAT THESE TEMPORARY THERMOSTATS ARE MOUNTED IN THE PROPER LOCATIONS 5, ANY SMOKE DETECTORS, SMOKE DAMPERS, FIRE DAMPERS, OR ASSOCIATED INTERLOCK WIRING FOR THESE LISTED. THIS WORK IS SPECIFIED TO BE DONE BY THE ELECTRICAL CONTRACTOR. 6. ANY ELECTRIC ZONE DAMPERS OR CONTROLS FOR SAME (IF SHOWN ON THE MECHANICAL CONSTRUCTION DRAWINGS). THIS EQUIPMENT IS FURNISHED AND INSTALLED BY THE HVAC CONTRACTOR. **CVS TM phar��� ����� STORE NUMBER: 00944 453 STATION AVENUE CONTRACTOR. THIS IS A SEPARATE ITEM 7. AOR TO DO DUE DILIGENCE ON ALL SOUTH YARMOUTH, MA 02664 Front Bench THAT IS SPECIFIED AND PROVIDED UNDER THE ELECTRICAL PLANS AND EXISTING SPACES FOR ANNUNCIATORS AND PROBE LOCATIONS. GC TO VERIFY CAP CODE: 00072 ___—MEN SPECIFICATIONS. 4 ROOFTTOPTEMPORARUN TSEAROESTATS FOR PROVIDEED BYTHECS HVAC CONTRACTOR. PLEASE BE LOCATIONS WITH LOCAL FIRE MARSHAL OR REVIEWER. ^ ' PRWECT NUMBER: 163445 miss RISER DIAGRAM NOTES 1. ALL EQUIPMENT SHOWN IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. THIS 2. PRIOR TO START OF WORK CONTRACTOR SHALL PROVIDE LABOR, TOOLS AND STARCK NOTE: `BOLD TEXT INDICATES NEW LOAD UTILISING EXISTING 2t A4P SPARE BREAKER IN PANEL. SINGLE LINE DIAGRAM WAS DEVELOPED THROUGH FIELD SURVEYS OF EXISTING CONDITIONS. IT IS INCLUDED IN THIS SET MATERIAL REQUIRED TO CIRCUIT TRACE THE EXISTING BRANCH CIRCUITRY TO THE EXISTING ELECTRICAL EQUIPMENT IDENTIFY ARCHITECTS 126 Cove Street TO PROVIDE THE CONTRACTOR WITH AN UNDERSTANDING OF THE OVERALL ON PLAN IN ORDER TO CONFIRM THE CIRCUITS BEING REUSED / MODIFIED IN Fall River, MA 02720 1 Richmond Square, Suite 120C EXISTING ELECTRICAL DISTRIBUTION BUT IS THIS CONTRACT. CONTRACTOR SHALL Providence, RI 02903 NOT MEANT TO BE ALL INCLUSIVE OF ALL DISTRIBUTION EQUIPMENT AS NOT ALL FEEDERS WERE LABELED, RE -LABEL ALL NEW / REUSED / MODIFIED CIRCUIT BREAKERS WHEN DONE. MA 508.679,5733 RI401.709.7799 STARCKARCHITECTS.COM CONSULTANT ENGINEER: EMS NOTES DO NOT CONNECT THE FOLLOWING ITEMS INTO CIRCUITS THAT ARE INDICATED TO BE THE EMS PANEL: CONNECTED TO THE EMS WERE BASED ON THE • PHOTO LAB EQUIPMENT • FREEZERS, COOLERS, REFRIGERATORS i ICE MERCHANDISER • FAST LANE MERCHANDISE (FILM) EXISTING PANEL SCHEDULES AND NEW WORK. ADDITIONAL CIRCUITS MAY BE REQUIRED TO BE CONNECTED TO THE EMS PER THE CVS REQUIREMENTS. DO NOT REUSE AN EMERGENCY i ATM LIGHTING/EMS CONTROLLED CIRCUIT. • DIGITAL SCREEN TRENDCAPS, i DIABETES CARE. i POWER DROPS IN RETAIL AREA CONSULTANT• SEAL: ED ARC ��S q�p S JF�y��� try _ 0 . 951251 n 0 J`o G� gC 13i of MPSSP REVISIONS: �Q I ri I I F] EXISTING EXISTING PANEL 'D' PANEL 'C' ❑ ❑ ❑ 120/208Y 120/208Y 125A 125A 42 POS 42 POS ❑ ❑ T 1 SPARES 14 SPARE EXISTING PANEL 'B1' 12D/208Y 225A 30 POS 4 SPARES EXISTING PANEL 'B2' 120/208Y 225A 30 POS 9 SPARES XISTING EMS EXISTING EXISTING PANEL 'A1' PANEL 'A2' EXISTING PANEL 'MDP' 120/208Y 120f208Y 120/208Y 225A 225 A ( 3PH/4W 30 POS 30 POS 800A 4 SPARES 0 SPARES DRAWING/REVIEWED BY: I'PY MJT CVS PROJECT MANAGER: SH DATE. 08/08/2022 EXISTING TELECOM EQUIP JOB NUMBER: 163445 TI TLE, SYMBOLS, RISER DIAGRAM EXISTING PLYWOOD BACKBOARD MEZZANINE EXISTING PLYWOOD ! BACKBOARD � & LOAD SUMMARY SHEET NUMBER: FINISHED FLOOR NOTE: NUMBER OF SPARE BREAKERS ARE EXISTING PER PANEL SCHEDULES PRESENT DURING FIELD SURVEY AE2_ ELECTRICAL RISER DIAGRAM COMMENTS: ��AE2SCALE: NOT TO SCALE s d • ■ J � • TOTAL LOAD # 1 d ads ;• ;. �.i d • ®� !ice M. ® i -���__�•ii® ®����_®� i ® ®III /1 /i i/ i/ !i 1/ • b " !t c� O N 00 00 SYMBOL LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT � DUPLEX RECEPTACLE 18" AFF QUAD RECEPTACLE 18" AFF � DUPLEX RECEPTACLE WITH ISOLATED GROUND 18" AFF +� QUAD RECEPTACLE WITH ISOLATED GROUND 18" AFF GROUND FAULT CURRENT INTERRUPTER TYPE RECEPTACLE AS NOTED GROUND FAULT INTERRUPTER QUAD RECEPTACLE OUTLET AS NOTED ® SPECIAL RECEPTACLE AS NOTED AS NOTED � CEILING DUPLEX RECEPTACLE JUNCTION BOX W/COVERPLATE -WALL MOUNTED AS NOTED ® MUD RING AS NOTED PD POWER DROP. REF DETAIL SHEET ® PUSHBUTTON AS NOTED � PANELBOARD � DISCONNECT SWITCH ® HDMI PORT AS NOTED Q1 SINGLE DATA INFORMATION OUTLET (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) (1) CATEGORY SE MODULAR JACKS (BLACK) TO STORE RACK (5) BLANK INSERTS (WHITE) 18" AFF UON Q 2+1 2 DATA & 1 VOICE INFORMATION OUTLET (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) (2) CATEGORY SE MODULAR JACKS (BLACK) TO STORE RACK (1) CATEGORY SE MODULAR. JACKS (GRAY) TO WHITE CABINET (3) BLANK INSERTS (WHITE) 18" AFF UON a3 THREE PORT INFORMATION OUTLET (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) (3) CATEGORY 6 MODULAR JACKS (BLACK) TO STORE RACK (3) BLANK INSERTS (WHITE) 18" AFF UON Q4+2 4 DATA & 2 VOICE INFORMATION OUTLET (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) (4) CATEGORY SE MODULAR. JACKS (BLACK) TO STORE RACK (2) CATEGORY SE MODULAR JACKS (GRAY) TO WHITE CABINET 18" AFF UON Q5+1 5 DATA & 1 VOICE INFORMATION OUTLET (1) SINGLE GANG 6-POSITION FACEPLATE (WHITE) (5} CATEGORY SE MODULAR JACKS (BLACK) TO STORE RACK (1) CATEGORY SE MODULAR JACKS .(GRAY} TO WHITE CABINET 18" AFF UON Q CAM SECURITY CAMERA INFORMATION OUTLET (1) TRACJACK SURFACE HOUSING BOX (1} CATEGORY 6 MODULAR JACKS (BLACK) TO STORE RACK (1} BLANK INSERTS (WHITE) AS NOTED O OCCUPANCY SENSOR CEILING MOUNTED AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE XX REFER TO ELECTRICAL NOTES S.P.S.T. LIGHT SWITCH 40" AFF UON �no DIMMING SWITCH WITH OCCUPANCY SENSOR 40" AFF UON �P S.P.S.T. LIGHT SWITCH WITH PILOT LIGHT 40" AFF UON �sT 60 MINUTE TIMER SWITCH (MARKTtME #90008) 40" AFF UON �2 D.P.S.T. SWITCH 40" AFF UON �S OCCUPANCY SENSOR (ACUITY .BRANDS LIGHTING #WSX PDT WH) SET TIME DELAY FOR 30 MINUTES 40" AFF UON �M MOTOR -RATED DISCONNECT SWITCH AS NOTED #XW WIRING SIZE o DOUBLE GANG PLASTER RING, RACO #769 FOR 5/8" DRYWALL NOTE: UNLESS OTHERWISE NOTED ALL OUTLETS &JUNCTION BOXES TO BE LOCATED 18" A.F.F. RECEPTACLES TO BE "LEVITON" #5362A-W (ALL DEVICES TO BE WHITE). REVIEW ELECTRICAL NOTES TO VERIFY CONDITIONS PER ELECTRICAL LEGEND. MOUNTING HEIGHT IS FROM FINISHED FLOOR TO CENTERLINE OF DEVICE OR OUTLET. HEIGHT MAY VARY TO COINCIDE WITH BUILDING CONSTRUCTION.