HomeMy WebLinkAbout453 Station Ave CVS plan 22PHARMACY 110 9'-0" CONSULTING ROOM 112 OPEN TO RETAI HALLWAY 109 8'-0" WOMEN'S RESTROOM 1 88 8'-0„ MEN'S RESTROOM 107 8'-0„ EMPLOYEE LOUNGE 105 8'-0" RECEIVING AREA 106 B.O.J: 13'-3 1 /I B.O.D: 14'-3 3/ 104 1 7'-11 1 /8" PARTIAL LIGHTING PLAN AE3 1 /8" = i'—on LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING VOLT VA LAMPS MANUFACTURER REMARKS/NOTES A 2X4 PARAPOLIC LED LITHONIA #2ESL4 48L EZ1 LP840 RECESSED 120 37 INCLUDING W/ UNIT LITHONIA EM SURFACE MOUNT EMERGENCY #ELM2 LED SURF MTD 120 1 LED LITHONIA CEILING MOUNTED IN RETAIL ONLY X1 ADA EXIT WITH REMOTE HEADS STX-C-CT-6-18-LR-1-W2SR-SWCT SURF MTD 120 1 LED BEGHELLI PROVIDE NO. OF FACES AND ARROW AS INDICATED ON PLANS CHECKOUT 102 11'-10 3/8" VESTIBULE 100 -71 11'-10 7/8" 1 \ L i ! 11 L f 1 I \ L / 9 I I p - - - - - - - - - - - - - - - - - - - - - - - - - - p 11'-10 11/16" �I --_-- ---------J UO GENERAL LIGHTING NOTES 1. REPAIR/REPLACE ALL DAMAGED OR 10, ROUTE THE FOLLOWING CIRCUITS THROUGH INOPERABLE EXISTING EXIT AND EMERGENCY THE ENERGY MANAGEMENT SYSTEM: LIGHT FIXTURES AND RECONNECT. A. ALL RETAIL AREA LIGHTING CIRCUITS. B. SIGNS AND EXTERNAL LIGHTING 2. REPLACE ALL LIGHTING FIXTURES WITHIN CIRCUITS. RETAIL AND PHARMACY. C. ALL LIGHTING CIRCUITS IN PHARMACY. D. PHOTOLAB AND CHECKOUT AREAS. 3. ALL LIGHTING FIXTURES AND LAMPS PROVIDED AND INSTALLED BY THE GC. 11. REFER TO LIGHTING FIXTURE SCHEDULE SHEET AE3 FOR ADDITIONAL INFORMATION. 4. GC SHALL BE RESPONSIBLE TO MAINTAIN ALL AUXILIARY SYSTEMS (ALARM, MUSIC, 12. REFER TO ARCHITECTURAL DRAWING A2 FOR CAMERAS, ETC.) IN AREAS OF CEILING EXACT LIGHTING FIXTURE LOCATIONS, REMOVAL/REWORK. INDEPENDENTLY UNLESS NOTED OTHERWISE. SUPPORT EQUIPMENT UNTIL CEILING WORK IS COMPLETE AND REINSTALL. COORDINATE 13. PROVIDE CONDUIT AND PULL WIRE FOR ALL WITH CVS PM FOR PLACEMENT. LOW VOLTAGE CIRCUITS. 5. AOR TO DO DUE DILIGENCE ON ALL 14. WIRE EXIT/EMERGENCY FIXTURES AHEAD OF EXISTING SPACES FOR ANNUNCIATORS AND SWITCHES ON RESPECTIVE CIRCUITS FOR STROBE LOCATIONS. GC TO VERIFY STOCK ROOM, PHARMACY AREA, LOCATIONS WITH FIRE MARSHAL OR RESTROOMS, HALL, MANAGER'S OFFICE, REVIEWER. HALL AND BREAK ROOM. SALES FLOOR TO HAVE DEDICATED LOCKED -ON 120V 6. GC TO CONFIRM ALL EXISTING CIRCUITS TO CIRCUITS. BE RE -USED IN FIELD. 15. FIXTURE WITH "NL" SHALL BE WIRED TO 7. EXIT SIGNS AND EMERGENCY LIGHTING OPERATE AS NIGHT LIGHT FIXTURE. HEADS IN RETAIL AREA SHALL BE CEILING MOUNTED. ALL EXIT SIGNS WIRED AC/DC 16. PROVIDE CONDUIT FOR WIRING AS SPECIFIED AND TOGETHER. IN DRAWINGS AND AS REQUIRED BY LOCAL JURISDICTION. COORDINATE INSTALLATION 8. INSTALL HOLD DOWN CLIPS ON ALL 2'x4' AND ROUTING REQUIRMENTS WITH LAY -IN LIGHT FIXTURES. APPROPRIATE INSTALLER. 9. CUT AND POP RIVET CEILING GRIDS AS REQUIRED. EMERGENCY LIGHTING GENERAL NOTE IF RELOCATED LIGHT FIXTURE IS EQUIPPED WITH EMERGENCY BATTERY, RECONNECT UNSWITCHED HOT WIRE TO EMERGENCY FIXTURE BATTERY CHARGER VIA LOCAL LIGHTING CIRCUIT. CONNECT SWITCHED (EMS) HOT WIRE CIRCUIT TO BOTH FIXTURE BALLASTS. EMERGENCY FIXTURE WILL OPERATE AS A SWITCHABLE UNIT WITH SEPARATE CIRCUIT FOR BATTERY CHARGER SO LAMPS CAN BE TURNED OFF WHILE CHARGER MAINTAINS BATTERY AT PROPER VOLTAGE, EMERGENCY LIGHTING WILL BE TURNED OFF BY THE EMS SYSTEM/ LIGHTING CONTROL PANEL. IN THE EVENT OF A POWER OUTAGE, ALL EMERGENCY FIXTURES WILL BE ACTIVATED. EXTEND EXISTING CIRCUIT AS NEEDED. SYMBOL LEGEND (THIS SHEET ONLY) SYMBOL DESCRIPTION MOUNTING HEIGHT 2X4 LIGHT 1X4 LIGHT STRIP LIGHT (EXISTING) MONOPOINT SPOT LIGHT SURFACE MOUNTED EMERGENCY LIGHT FIXTURE e®e SURFACE MOUNTED EXIT FIXTURE LIGHT O CEILING MOUNTED OCCUPANCY SENSOR $S OCCUPANCY SENSOR (ACUITY BRANDS LIGHTING WSX-PDT-WH) SET TIME DELAY FOR 30 MINUTES 42" AFF UON °O DIMMING SWITCH WITH OCCUPANCY SENSOR 42" AFF UON S.P.S.T. LIGHT SWITCH 42" AFF UON NOT LABELED EXISTING TO REMAIN — N NEW LIGHT FIXTURE RE EXISTING TO BE RELOCATED - D DEMOLISHED KEYED NOTES - LIGHTING NEW WORK 1. RELAMP AND REBALLAST ALL 4. INSTALL NEW LIT EXIT SIGN W/ ISA AS NON -WORKING LIGHT FIXTURES AS SHOWN REQUIRED. G.C. TO PROVIDE ADDITIONAL BOX OF EACH TYPE OF BULB FOR 5. INSTALL (3) NEW MONPOINT LIGHT FUTURE STORE USE. FIXTURES AS SHOWN 2. INSTALL (25) NEW 2X4 LIGHT FIXTURES) 6. INSTALL RELOCATE/NEW POWER POLE AS TO MATCH EXISTING SHOWN 3. INSTALL NEW EMERGENCY LIGHT FIXTURE. CONNECT TO EXISTING RETAIL LIGHTING CIRCUIT AS SHOW, GC TO COORDINATE WITH CVS VENDOR FOR RELOCATION /REINSTALLATION OF ALL CAMERAS, MOTION DETECTORS, SECURITY EQUIPMENT INCLUDING FIRE ALARM EQUIPMENT. CVS HAS DEVELOPED SPECIAL PRICING AND READILY AVAILABLE STOCK WITH THE NAl PREFERRED VENDORS. SUPPLIER: WIEDENBACH-BROWN CO, INC. PHONE: 800-243-6980 EMAIL: CVSSUPPORT @WBLIGHT.COM SUPPLIER: NESCO, INC. PHONE: 888-244-6980 EMAIL: CVSPLANS@NEEDHAMELECTRIC.COM %*Cvs pharmacy" RESET STORE NUMBER: 00944 453 STATION AVENUE SOUTH YARMOUTH, MA 02664 CAP CODE: 00072 CS PROJECT NUMBER: 163445 STARC K ARCHITECTS 126 Cove Street Fall River, MA 02720 1 Richmond Square, Suite 120C Providence, RI 02903 MA 508.679.5733 RI 401.709.7799 STARCKARCHITECTS.COM CONSULTANT ENGINEER CONSULTANT SEAL: RED ARcy x�F .951251 G� `Fq4 77q OF MPSSP REVISIONS: DRAWING/REVIEWED BY: PPY/MJT CVS PROJECT MANAGER: SH DATE: 08/08/2022 JOB NUMBER: 163445 TI TLE: ARCH. LIGHTING PLAN SHEET NUMBER: AE3. COMMENTS: