HomeMy WebLinkAbout453 Station Ave CVS plan 23Q
0
Ln
rr;
o�
N
N
0
N
00
00
TO EXISTING
CIRCUIT
TO EXISTING
CIRCUIT
TO EXISTING
CIRCUIT ,
JUNCTION BOX MOUNTED _ JUNCTION BOX MOUNTED J
FLUSH WITH CEILING FLUSH WITH CEILING s� wdEjw
NoJ
GRID, SECURE TO CEILING GRID, SECURE TO CEILING
STRUCTURE ABOVE STRUCTURE ABOVE
TO EXISTING TO xs ❑
CIRCUIT EXISTING
(WHITE) JUNCTION BOX NOTE: (WHITE) JUNCTION BOX 5 CIRCUIT
PROVIDE POWER TO CLOSURE PLATE, DRILL o
CLOSURE PLATE, DRILL GONDOLA VIA SO CORD HOLE FOR STRAIN KPK
HOLE FOR STRAIN rr, '
RELIEF AND CORD WITH ALL COMPONENTS RELIEF AND SO CORD NOTE: WHITE POWER
INCLUDING BUT NOT POLE WITH JUNCTION TO EXISTING
LIMITED TO STRAIN BOX TO BE TERMINATED CIRCUIT
RELIEF FOR A COMPLETE (WHITE) SO CORD
(WHITE) SO CORD DOWN AND STATIONARY DOWN TO 6" ABOVE FINISHED I
TO GONDOLA BELOW CEILING.
INSTALLATION. JUNCTION GONDOLA BELOW
BOX TO BE FLUSH
TO
JUNCTION BOX AT TOP --AMOUNTED WITH CEILING s EXISCRCUITTING „v —U
RAIL FOR BEACON GRID AND SECURED TO JUNCTION BOX AT LOW VOLTAGE
0
(F
OR
GONDOLA ONLY) STRUCTURE ABOVE. FLOOR LEVEL (FOR OUTLET
POWER DROP TO BE REGULAR GONDOLA) 4
USED AS LEGRAND DUPLEX OUTLET m M
WIREMOLD POWER POWERED BY o ,�
FLOOR DROP PD123180WH MALE PLUG o TO EXISTING
FLOOR CIRCUIT
❑'
DETAIL FOR BEACON FIXTURE ONLY DETAIL FOR REGULAR FIXTURE
2 POWER DROP SUPPLY DETAIL 3 POWER POLE DETAIL 4 ELECTRICAL - PHOTOLAB
AE4 SCALE: N.T.S. AE4 SCALE: NTS AE4 SCALE: 1/4" = 1'-0"
(CLOSED) HH (CLOSED) HH
Rx WAITING EXAM ROOM #1 EXAM ROOM #2
111F 1-15-1116
8'-11 11 /16" P14 7'-11 11 /16" 7'-11 5/16"
5-8 7/16" ---
PHARMACY
11O
9'-0"
CONSULTING
ROOM
112 °
OPEN TO RETAIL
j
HALLWAY 1
109 1! �I
8'-0"
WOMEN'S
RESTROOM ®° F
108
8,-0"
MEN'S
RESTROOM
107
8'-0"
EMPLOYEE
LOUNGE
105
8'-0"
GO
RECEIVING
AREA
106
B.O.J: 13-3 1 /8
B.O.D: 14'-3 3/4
— I C-10
EXTEND EXIST BLOOD
RESSURE MACHIN
CIRCUIT TO NEW
° LOCATION AS R
,o
MANAGER'S
OFFICE
Fl-0-41
7'-11 1 /8"
POWER PLAN
AE4 SCALE: 1/8" = 1'-0"
C-6
Li
ME
EXTEND EXISTING WECC
CIRCUIT TO NEW
LOCATION AS REQUIRED
RE
LJ
■
RETAIL AREA
101 °
11'-10 11/16"
GC TO COORDINATE WITH CVS VENDOR FOR RELOCATION /REINSTALLATION OF
ALL CAMERAS, MOTION DETECTORS, SECURITY EQUIPMENT INCLUDING FIRE
ALARM EQUIPMENT,
KEYED NOTES - PHOTOLAB AREA
OPROVIDE (2) J—BOXES. (1) FOR POWER & (1) FOR LOW VOLTAGE WIRING.
MOUNT BELOW COUNTER TOP.
OPROVIDE ONE (1)—NEMA 5-15R QUAD RECEPTACLE FLUSH MOUNTED 24"AFF.
PROVIDE 1 JUNCTION BOX AT 14" AFF, WITH 1" CONDUIT WITH PULLWIRE AT
24" ABOVE CEILING.
4� PROVIDE ONE (2) NEMA 5-15R QUAD RECEPTACLES SURFACE MOUNTED
BELOW COUNTER TOP.
OPROVIDE ONE (1) NEMA 5-15R DUPLEX RECEPTACLE SURFACE MOUNTED AT
14" AFF.
OPROVIDE ONE (1) NEMA 5-15R DUPLEX RECEPTACLES FLUSH MOUNTED 24"
AFF.
OPROVIDE (1) DUPLEX RECEPTACLE & DATA OUTLET MOUNTED BELOW COUNTE
FOR MONEYGRAM KIOSK. INSTALL POWER & DATA IN FLEXIBLE CORRUGATED
TUBING BLACK DIAMETER BETWEEN MONEYGRAM KIOSK & PHOTO LAB
COUNTER.
NOTE:
1. DO NOT CONNECT PHOTO LAB EQUIPMENT TO EMS PANEL.
2. COORDINATE EXACT LOCATION OF ALL ELECTRICAL CONNECTIONS WITH OTHER TRADES.
3. ALL CIRCUITS ABOVE MUST BE ON A DEDICATED CIRCUIT.
DESIGNER NOTES:
— WHEN INSTALLING NEW POWER DROPS, EXISTING CIRCUITS ARE NOT TO BE UTILIZED, NOR
ARE NEW CIRCUITS TO BE CONNECTED TO THE EMS.
— ALL NEW POWER DROPS MUST BE HOME —RUN ON THEIR OWN DESIGNATED CIRCUITS. DAISY
CHAINING CAN OCCUR WITHIN THESE NEW DESIGNATED CIRCUITS, AS LONG AS THEY ARE
ONLY CONFINED TO THOSE DESIGNATED CIRCUITS.
— TRENDCAPS THAT REQUIRE ADDITIONAL POWER MAY HAVE THEIR OWN DESIGNATED
CIRCUITS AS LONG AS THEY ARE CONFINED TO THOSE DESIGNATED CIRCUITS.
— IF MORE THAN ONE CIRCUIT IS REQUIRED FOR TRENDCAPS DESIGNATION, MORE MAY BE
UTILIZED.
— IF AN ADDITIONAL PANEL IS REQUIRED FOR THESE NEW CIRCUIT CONDITIONS, IT MAY BE
ADDED.
EXTEND EXISTING EXTEND EXISTING WECC
SEASONAL CIRCUITS TO AND SEASONAL CIRCUITS
NEW LOCATION AS TO NEW LOCATION AS WALK-IN
REQUIRED REQUIRED COOLER
P1 PP 8 DOORS
�
os ME
P4 PP P4 PP
� I LIP--
� 1°
P19 P19
I
P20
P 19 P 19 29X13X60
4IT M TT I
1
AE4
P19 P19 1 x3a< °
36" KPK 1
1
1 jl
�1
1 220 1 P19
z W 1
' ) I mm l
1
PD P, ( 0
r--� L
C-4
BATT P 2
DI
0
C-2 o I
P9 � z
bI
N D
= r
r
EXTEND EXISTING T'
FLM CIRCUITS TO P6 ®®�
NEW LOCATION AS TRIPLE
REQUIRED CART CORRAL
FULL HEIGHT
EXTEND EXISTING
ATM CIRCUIT TO P5
NEW LOCATION AS
REQUIRED
PHOTO LAB
103
11'-10 3/8"
CHECKOUT
102
11'-10 3/8"
VESTIBULE
Fl-00-1
11'-10 7/8"
IMI Ilnll ICI L°'11
NOTE: EXISTING POWER POLES AND GONDOLAS BEING
RELOCATED BASED ON THE FINAL MERCHANDISE PLAN.
GC SHALL COORDINATE WITH FINAL MERCHANDISE
PLAN TO IDENTIFYING GONDOLAS AND POWER POLES
TO BE RELOCATED AND SHALL RELOCATE AS
REQUIRED. RECONNECT GONDOLA WIRING CHASE
CIRCUITS TO EXISTING CIRCUITS. VERIFY CHASE IS
WORKING AFTER INSTALLATION.
GENERAL NOTES
1. CONTRACTOR SHALL COORDINATE
5.
REUSE EXISTING CIRCUITS FROM
ALL FINAL LOCATIONS FOR POINTS
REMOVED EQUIPMENT WHEN
OF ELECTRICAL SERVICE (JUNCTION
POSSIBLE, ABANDONED CIRCUITS
BOXES, STUB —UPS, RECEPTACLES,
SHALL BE REMOVED BACK TO
TELE/DATA OUTLETS, ETC.) WITH
SOURCE.
EQUIPMENT INSTALLER AND CVS
REPRESENTATIVE PRIOR TO
6.
CONTRACTOR TO VERIFY ALL
INSTALLATION.
EXISTING PANEL LOADING IN FIELD
AS REQUIRED PRIOR ANY NEW
2. ELECTRICAL CONTRACTOR SHALL
WORK.
LABEL SPARE IN PANEL(S) OF ALL
CIRCUITS TO BE ABANDONED FROM
7
PANEL CIRCUIT DIRECTORY TO
REMODEL OF STORE.
COMPLY WITH SEC 408.4. CEC.
3. ALL UNUSED WIRING IN
8.
MOUNT THE FOLLOWING ABOVE
CEILING/FLOOR SPACE SHALL BE
FINISH FLOOR:
PULLED BACK TO SOURCE AND
OUTLETS 18" TO 48"
REMOVED.
SWITCHES 36" TO 48"
THERMOSTAT 36" TO 48"
4. REFER TO ARCHITECTURAL PLANS
AND ELECTRICAL PLAN FOR
DEMOLITION.
KEYED NOTES - NEW WORK
PROVIDE POWER TO GONDOLA VIA POWER DROP WITH ALL COMPONENTS
INCLUDING BUT NOT LIMITED TO STRAIN RELIEF FOR A COMPLETE AND
P1 STATIONARY INSTALLATION. J—BOX TO BE FLUSH MOUNTED WITH CEILING
GRID AND SECURED TO STRUCTURE ABOVE. RE 2/AE4
INSTALL QUAD RECEPTACLE MOUNTED SIDEWAY ON GONDOLA BASE FOR
P2 SHELVES LIGHTING. CONCEAL ALL WIRING FROM RECEPTACLE TO POWER
DROP WITHIN GONDOLA. COMPLETE ALL SHELVES LIGHTING CONNECTION AS
REQUIRED. DO NOT CONNECT TO EMS/TIMER. REF TO 2/AE4.
P3 NOT USED
PROVIDE WIRING CHASE AS MANUFACTURED BY WEIDENBACH—BROWN WITH
OALL COMPONENTS FOR A COMPLETE AND STATIONARY INSTALLATION.
P4 PROVIDE JUNCTION BOX 6" ABOVE CEILING FOR WIRING CHASE CONNECTION,
VERIFY LENGTH OF WIRING CHASE REQUIRED PRIOR TO ORDERING.
RELOCATED ATM WITH ASSOCIATED CONTROLS. EXTEND DEDICATED CIRCUIT
P5 AS NEEDED. DO NOT CONNECT TO EMS. COORDINATE WITH ATM VENDOR
PRIOR TO ANY WORK.
P6 RELOCATED FLM WITH ASSOCIATED CONTROL. EXTEND CIRCUIT AS NEEDED.
P7 NOT USED
P8 NOT USED.
P9 REINSTALL CHECKOUT ELECTRICAL COMPONENTS. EXTEND EXISTING CIRCUITS
AS NEEDED.
P10 NOT USED
OPROVIDE 1" CONDUIT DOWN TO V-6" AFF TO J—BOX WITH PULLSTRING FOR
P11 LOW VOLTAGE WIRING.
P12 NOT USED
P13 NOT USED
P14 PROVIDE RECEPTACLE FLUSH MOUNTED 3" FROM TOP OF RECEPTACLE TO
TOP OF SCREEN FOR TV. COORDINATE WITH ARCH INTERIOR ELEVATIONS.
REFER TO DETAIL 5/AE4.
PROVIDE DATA OUTLET FLUSH MOUNTED 3" FROM TOP OF OUTLET TO TOP
P15 OF SCREEN FOR TV. COORDINATE WITH ARCH INTERIOR ELEVATIONS. REFER
TO DETAIL 5/AE4.
P16 PROVIDE / RELOCATE POWER POLE FOR FUTURE USE IN Rx CONSULT
ROOM. REFER TO POWER POLE DETAIL.
P17 NOT USED
P18 NOT USED
INSTALL NEW/RELOCATED GFI TOP RAIL OUTLET. CONCEAL ALL WIRING FROM
P19 OUTLET TO WIRING CHASE/POWER DROP WITHIN GONDOLA
OWECC/ECC W/ DUPLEX & DATA/PHONE LINE MOUNTED ON FIXTURE.
P20 PROVIDE ALL COMPONENTS FOR A COMPLETE & STATIONARY INSTALLATION.
WIRING FROM OUTLET TO WIRING CHASE WITHIN GONDOLA
P21 INSTALL ALARM DOOR SENOR AT NEW Rx CONSULTING ROOM DOOR
P22 RECONNECT EXISTING ELECTRICAL TO EXISTING PHARMACY CIRCUIT(S) AS
REQUIRED
P23 NOT USED
P24 NOT USED
P25 PROVIDE DUPLEX RECEPTACLE @ 18" AFF, FOR BLOOD PRESSURE MACHINE
AS SHOWN
NOTE: DO NOT CONNECT TELEVISION OR PRN COMMUNICATIONS EQUIPMENT TO EMS PANEL.
• COORDINATE EXACT LOCATION OF ALL ELECTRICAL CONNECTIONS WITH OTHER TRADES.
CONTRACTOR TO VERIFY ALL EXISTING PANEL LOADING IN FIELD AS
REQUIRED PRIOR ANY NEW WORK.
• ELECTRIC JUNCTION BOXES TO BE 3" BELOW TOP OF TV, 6" APART
• GC TO CONFIRM EITHER EXISTING OUTLET/CIRCUIT IS NOT CONNECTED TO EMS, OR NEW
HOME RUN TO ELECTRICAL PANEL
6"
WALL-------------
f
DATA
OUTLET
(2) DUPLEX
RECEPTACLES
_ED TV
I
I
I
AE4 SCALE: 1 /2" = 1"-0"
**CVS
arm acy"'
RESET
STORE NUMBER 00944
453 STATION AVENUE
SOUTH YARMOUTH, MA 02664
CAP CODE: 00072
CS PROJECT NUMBER 163445
STARCK
ARCHITECTS
126 Cove Street
Fall River, MA 02720
1 Richmond Square, Suite 120C
Providence, RI 02903
MA 508.679.5733
RI 401.709.7799
STARCKARCHITECTS.COM
CONSULTANT ENGINEER:
CONSULTANT
SEAL
��4ZECJ A/�c
Z �0
.9512
�y
OFgC?H OF MPSSAG
REVISIONS:
DRAWING/REVIEWED BY: PPY/MJT
CVS PROJECT MANAGER: SH
DATE: 08/08/2022
JOB NUMBER: 163445
TI TLE:
ARCH. POWER PLAN
SHEET NUMBER:
AE4_
COMMENTS: