HomeMy WebLinkAbout453 Station Ave CVS plan 23Q 0 Ln rr; o� N N 0 N 00 00 TO EXISTING CIRCUIT TO EXISTING CIRCUIT TO EXISTING CIRCUIT , JUNCTION BOX MOUNTED _ JUNCTION BOX MOUNTED J FLUSH WITH CEILING FLUSH WITH CEILING s� wdEjw NoJ GRID, SECURE TO CEILING GRID, SECURE TO CEILING STRUCTURE ABOVE STRUCTURE ABOVE TO EXISTING TO xs ❑ CIRCUIT EXISTING (WHITE) JUNCTION BOX NOTE: (WHITE) JUNCTION BOX 5 CIRCUIT PROVIDE POWER TO CLOSURE PLATE, DRILL o CLOSURE PLATE, DRILL GONDOLA VIA SO CORD HOLE FOR STRAIN KPK HOLE FOR STRAIN rr, ' RELIEF AND CORD WITH ALL COMPONENTS RELIEF AND SO CORD NOTE: WHITE POWER INCLUDING BUT NOT POLE WITH JUNCTION TO EXISTING LIMITED TO STRAIN BOX TO BE TERMINATED CIRCUIT RELIEF FOR A COMPLETE (WHITE) SO CORD (WHITE) SO CORD DOWN AND STATIONARY DOWN TO 6" ABOVE FINISHED I TO GONDOLA BELOW CEILING. INSTALLATION. JUNCTION GONDOLA BELOW BOX TO BE FLUSH TO JUNCTION BOX AT TOP --AMOUNTED WITH CEILING s EXISCRCUITTING „v —U RAIL FOR BEACON GRID AND SECURED TO JUNCTION BOX AT LOW VOLTAGE 0 (F OR GONDOLA ONLY) STRUCTURE ABOVE. FLOOR LEVEL (FOR OUTLET POWER DROP TO BE REGULAR GONDOLA) 4 USED AS LEGRAND DUPLEX OUTLET m M WIREMOLD POWER POWERED BY o ,� FLOOR DROP PD123180WH MALE PLUG o TO EXISTING FLOOR CIRCUIT ❑' DETAIL FOR BEACON FIXTURE ONLY DETAIL FOR REGULAR FIXTURE 2 POWER DROP SUPPLY DETAIL 3 POWER POLE DETAIL 4 ELECTRICAL - PHOTOLAB AE4 SCALE: N.T.S. AE4 SCALE: NTS AE4 SCALE: 1/4" = 1'-0" (CLOSED) HH (CLOSED) HH Rx WAITING EXAM ROOM #1 EXAM ROOM #2 111F 1-15-1116 8'-11 11 /16" P14 7'-11 11 /16" 7'-11 5/16" 5-8 7/16" --- PHARMACY 11O 9'-0" CONSULTING ROOM 112 ° OPEN TO RETAIL j HALLWAY 1 109 1! �I 8'-0" WOMEN'S RESTROOM ®° F 108 8,-0" MEN'S RESTROOM 107 8'-0" EMPLOYEE LOUNGE 105 8'-0" GO RECEIVING AREA 106 B.O.J: 13-3 1 /8 B.O.D: 14'-3 3/4 — I C-10 EXTEND EXIST BLOOD RESSURE MACHIN CIRCUIT TO NEW ° LOCATION AS R ,o MANAGER'S OFFICE Fl-0-41 7'-11 1 /8" POWER PLAN AE4 SCALE: 1/8" = 1'-0" C-6 Li ME EXTEND EXISTING WECC CIRCUIT TO NEW LOCATION AS REQUIRED RE LJ ■ RETAIL AREA 101 ° 11'-10 11/16" GC TO COORDINATE WITH CVS VENDOR FOR RELOCATION /REINSTALLATION OF ALL CAMERAS, MOTION DETECTORS, SECURITY EQUIPMENT INCLUDING FIRE ALARM EQUIPMENT, KEYED NOTES - PHOTOLAB AREA OPROVIDE (2) J—BOXES. (1) FOR POWER & (1) FOR LOW VOLTAGE WIRING. MOUNT BELOW COUNTER TOP. OPROVIDE ONE (1)—NEMA 5-15R QUAD RECEPTACLE FLUSH MOUNTED 24"AFF. PROVIDE 1 JUNCTION BOX AT 14" AFF, WITH 1" CONDUIT WITH PULLWIRE AT 24" ABOVE CEILING. 4� PROVIDE ONE (2) NEMA 5-15R QUAD RECEPTACLES SURFACE MOUNTED BELOW COUNTER TOP. OPROVIDE ONE (1) NEMA 5-15R DUPLEX RECEPTACLE SURFACE MOUNTED AT 14" AFF. OPROVIDE ONE (1) NEMA 5-15R DUPLEX RECEPTACLES FLUSH MOUNTED 24" AFF. OPROVIDE (1) DUPLEX RECEPTACLE & DATA OUTLET MOUNTED BELOW COUNTE FOR MONEYGRAM KIOSK. INSTALL POWER & DATA IN FLEXIBLE CORRUGATED TUBING BLACK DIAMETER BETWEEN MONEYGRAM KIOSK & PHOTO LAB COUNTER. NOTE: 1. DO NOT CONNECT PHOTO LAB EQUIPMENT TO EMS PANEL. 2. COORDINATE EXACT LOCATION OF ALL ELECTRICAL CONNECTIONS WITH OTHER TRADES. 3. ALL CIRCUITS ABOVE MUST BE ON A DEDICATED CIRCUIT. DESIGNER NOTES: — WHEN INSTALLING NEW POWER DROPS, EXISTING CIRCUITS ARE NOT TO BE UTILIZED, NOR ARE NEW CIRCUITS TO BE CONNECTED TO THE EMS. — ALL NEW POWER DROPS MUST BE HOME —RUN ON THEIR OWN DESIGNATED CIRCUITS. DAISY CHAINING CAN OCCUR WITHIN THESE NEW DESIGNATED CIRCUITS, AS LONG AS THEY ARE ONLY CONFINED TO THOSE DESIGNATED CIRCUITS. — TRENDCAPS THAT REQUIRE ADDITIONAL POWER MAY HAVE THEIR OWN DESIGNATED CIRCUITS AS LONG AS THEY ARE CONFINED TO THOSE DESIGNATED CIRCUITS. — IF MORE THAN ONE CIRCUIT IS REQUIRED FOR TRENDCAPS DESIGNATION, MORE MAY BE UTILIZED. — IF AN ADDITIONAL PANEL IS REQUIRED FOR THESE NEW CIRCUIT CONDITIONS, IT MAY BE ADDED. EXTEND EXISTING EXTEND EXISTING WECC SEASONAL CIRCUITS TO AND SEASONAL CIRCUITS NEW LOCATION AS TO NEW LOCATION AS WALK-IN REQUIRED REQUIRED COOLER P1 PP 8 DOORS � os ME P4 PP P4 PP � I LIP-- � 1° P19 P19 I P20 P 19 P 19 29X13X60 4IT M TT I 1 AE4 P19 P19 1 x3a< ° 36" KPK 1 1 1 jl �1 1 220 1 P19 z W 1 ' ) I mm l 1 PD P, ( 0 r--� L C-4 BATT P 2 DI 0 C-2 o I P9 � z bI N D = r r EXTEND EXISTING T' FLM CIRCUITS TO P6 ®®� NEW LOCATION AS TRIPLE REQUIRED CART CORRAL FULL HEIGHT EXTEND EXISTING ATM CIRCUIT TO P5 NEW LOCATION AS REQUIRED PHOTO LAB 103 11'-10 3/8" CHECKOUT 102 11'-10 3/8" VESTIBULE Fl-00-1 11'-10 7/8" IMI Ilnll ICI L°'11 NOTE: EXISTING POWER POLES AND GONDOLAS BEING RELOCATED BASED ON THE FINAL MERCHANDISE PLAN. GC SHALL COORDINATE WITH FINAL MERCHANDISE PLAN TO IDENTIFYING GONDOLAS AND POWER POLES TO BE RELOCATED AND SHALL RELOCATE AS REQUIRED. RECONNECT GONDOLA WIRING CHASE CIRCUITS TO EXISTING CIRCUITS. VERIFY CHASE IS WORKING AFTER INSTALLATION. GENERAL NOTES 1. CONTRACTOR SHALL COORDINATE 5. REUSE EXISTING CIRCUITS FROM ALL FINAL LOCATIONS FOR POINTS REMOVED EQUIPMENT WHEN OF ELECTRICAL SERVICE (JUNCTION POSSIBLE, ABANDONED CIRCUITS BOXES, STUB —UPS, RECEPTACLES, SHALL BE REMOVED BACK TO TELE/DATA OUTLETS, ETC.) WITH SOURCE. EQUIPMENT INSTALLER AND CVS REPRESENTATIVE PRIOR TO 6. CONTRACTOR TO VERIFY ALL INSTALLATION. EXISTING PANEL LOADING IN FIELD AS REQUIRED PRIOR ANY NEW 2. ELECTRICAL CONTRACTOR SHALL WORK. LABEL SPARE IN PANEL(S) OF ALL CIRCUITS TO BE ABANDONED FROM 7 PANEL CIRCUIT DIRECTORY TO REMODEL OF STORE. COMPLY WITH SEC 408.4. CEC. 3. ALL UNUSED WIRING IN 8. MOUNT THE FOLLOWING ABOVE CEILING/FLOOR SPACE SHALL BE FINISH FLOOR: PULLED BACK TO SOURCE AND OUTLETS 18" TO 48" REMOVED. SWITCHES 36" TO 48" THERMOSTAT 36" TO 48" 4. REFER TO ARCHITECTURAL PLANS AND ELECTRICAL PLAN FOR DEMOLITION. KEYED NOTES - NEW WORK PROVIDE POWER TO GONDOLA VIA POWER DROP WITH ALL COMPONENTS INCLUDING BUT NOT LIMITED TO STRAIN RELIEF FOR A COMPLETE AND P1 STATIONARY INSTALLATION. J—BOX TO BE FLUSH MOUNTED WITH CEILING GRID AND SECURED TO STRUCTURE ABOVE. RE 2/AE4 INSTALL QUAD RECEPTACLE MOUNTED SIDEWAY ON GONDOLA BASE FOR P2 SHELVES LIGHTING. CONCEAL ALL WIRING FROM RECEPTACLE TO POWER DROP WITHIN GONDOLA. COMPLETE ALL SHELVES LIGHTING CONNECTION AS REQUIRED. DO NOT CONNECT TO EMS/TIMER. REF TO 2/AE4. P3 NOT USED PROVIDE WIRING CHASE AS MANUFACTURED BY WEIDENBACH—BROWN WITH OALL COMPONENTS FOR A COMPLETE AND STATIONARY INSTALLATION. P4 PROVIDE JUNCTION BOX 6" ABOVE CEILING FOR WIRING CHASE CONNECTION, VERIFY LENGTH OF WIRING CHASE REQUIRED PRIOR TO ORDERING. RELOCATED ATM WITH ASSOCIATED CONTROLS. EXTEND DEDICATED CIRCUIT P5 AS NEEDED. DO NOT CONNECT TO EMS. COORDINATE WITH ATM VENDOR PRIOR TO ANY WORK. P6 RELOCATED FLM WITH ASSOCIATED CONTROL. EXTEND CIRCUIT AS NEEDED. P7 NOT USED P8 NOT USED. P9 REINSTALL CHECKOUT ELECTRICAL COMPONENTS. EXTEND EXISTING CIRCUITS AS NEEDED. P10 NOT USED OPROVIDE 1" CONDUIT DOWN TO V-6" AFF TO J—BOX WITH PULLSTRING FOR P11 LOW VOLTAGE WIRING. P12 NOT USED P13 NOT USED P14 PROVIDE RECEPTACLE FLUSH MOUNTED 3" FROM TOP OF RECEPTACLE TO TOP OF SCREEN FOR TV. COORDINATE WITH ARCH INTERIOR ELEVATIONS. REFER TO DETAIL 5/AE4. PROVIDE DATA OUTLET FLUSH MOUNTED 3" FROM TOP OF OUTLET TO TOP P15 OF SCREEN FOR TV. COORDINATE WITH ARCH INTERIOR ELEVATIONS. REFER TO DETAIL 5/AE4. P16 PROVIDE / RELOCATE POWER POLE FOR FUTURE USE IN Rx CONSULT ROOM. REFER TO POWER POLE DETAIL. P17 NOT USED P18 NOT USED INSTALL NEW/RELOCATED GFI TOP RAIL OUTLET. CONCEAL ALL WIRING FROM P19 OUTLET TO WIRING CHASE/POWER DROP WITHIN GONDOLA OWECC/ECC W/ DUPLEX & DATA/PHONE LINE MOUNTED ON FIXTURE. P20 PROVIDE ALL COMPONENTS FOR A COMPLETE & STATIONARY INSTALLATION. WIRING FROM OUTLET TO WIRING CHASE WITHIN GONDOLA P21 INSTALL ALARM DOOR SENOR AT NEW Rx CONSULTING ROOM DOOR P22 RECONNECT EXISTING ELECTRICAL TO EXISTING PHARMACY CIRCUIT(S) AS REQUIRED P23 NOT USED P24 NOT USED P25 PROVIDE DUPLEX RECEPTACLE @ 18" AFF, FOR BLOOD PRESSURE MACHINE AS SHOWN NOTE: DO NOT CONNECT TELEVISION OR PRN COMMUNICATIONS EQUIPMENT TO EMS PANEL. • COORDINATE EXACT LOCATION OF ALL ELECTRICAL CONNECTIONS WITH OTHER TRADES. CONTRACTOR TO VERIFY ALL EXISTING PANEL LOADING IN FIELD AS REQUIRED PRIOR ANY NEW WORK. • ELECTRIC JUNCTION BOXES TO BE 3" BELOW TOP OF TV, 6" APART • GC TO CONFIRM EITHER EXISTING OUTLET/CIRCUIT IS NOT CONNECTED TO EMS, OR NEW HOME RUN TO ELECTRICAL PANEL 6" WALL------------- f DATA OUTLET (2) DUPLEX RECEPTACLES _ED TV I I I AE4 SCALE: 1 /2" = 1"-0" **CVS arm acy"' RESET STORE NUMBER 00944 453 STATION AVENUE SOUTH YARMOUTH, MA 02664 CAP CODE: 00072 CS PROJECT NUMBER 163445 STARCK ARCHITECTS 126 Cove Street Fall River, MA 02720 1 Richmond Square, Suite 120C Providence, RI 02903 MA 508.679.5733 RI 401.709.7799 STARCKARCHITECTS.COM CONSULTANT ENGINEER: CONSULTANT SEAL ��4ZECJ A/�c Z �0 .9512 �y OFgC?H OF MPSSAG REVISIONS: DRAWING/REVIEWED BY: PPY/MJT CVS PROJECT MANAGER: SH DATE: 08/08/2022 JOB NUMBER: 163445 TI TLE: ARCH. POWER PLAN SHEET NUMBER: AE4_ COMMENTS: