HomeMy WebLinkAbout453 Station Ave CVS plan 4UUUR HAKUWARE SCHEDULE HARDWARE SET NO. 2; MANAGER'S OFFICE, EMPLOYEE, AND TOILET ROOMS: 3 EA. HINGE, 4-1/2, STD. WT. CB179NRP 4-1/2 X 4-1/2 1 EA. CYLINDRICAL LOCK WITH 93K-7-D-15-D-S3 X L/C THRU BOLTS 1 EA. CYLINDRICAL LOCK WITH B-AU-NTB620NR THRU BOLTS 1 3/4" X LC X 694 X 497 (1-1/4 UP) X 380AN (EMPLOYEE ONLY) 1 EA. PRIVACY LOCK WITH 93K-0-L-15-D-S3 (TOILET ROOMS ONLY) THRU BOLTS 1 EA. CYLINDER CORE 1 CC-OBP (CONST. CORE BLACK PLASTIC) (MNGR & EMPLOYEE ONLY) 1 EA. CLOSER 8616 ARP COV SNB1-REGULAR ARM 1 EA. WALL STOP 409 1 EA. DOOR VIEWER 622 (UL LISTED WIDE ANGLE)(MNGR ONLY) 3 EA. SILENCER 608 (EMPLOYEE & TOILET ROOMS ONLY) 1 EA. LITE (GLAZING) L-FRA100 8 W X 26 H (EMPLOYEE ONLY AND OCCASIONALLY MANAGER) HARDWARE SET NO. 3; PHARMACY: 3 EA. HINGE, 4-1/2, STD. WT. CB179NRP 4-1/2 X 4-1/2 1 EA. CYLINDRICAL LOCK WITH 93K-7-D-15-D-S3 X L/C THRU BOLTS 1 EA. CYLINDER CORE 1CC-OBP (CONST. CORE BLACK PLASTIC) 1 EA. CLOSER 8616 ARP COV SNB1 1 EA. FLOOR STOP 442 1 EA. DOOR VIEWER 622 (UL LISTED WIDE ANGLE) 3 EA. DOOR VIEWER ROCKWOOD GREY SILENCERS 6. FLOOR TILE: OVER INTERIOR CONCRETE SUBSTRATES, INSTALL IN ACCORDANCE WITH TCA 2 COATS LATEX EGGSHELL HANDBOOK METHOD F113, DRY -SET OR LATEX-PORTLAND CEMENT BOND COAT, WITH STANDARD GROUT, UNLESS OTHERWISE INDICATED. ?6D STA 6. INTERIOR WOOD DOORS. i26 BES 7. WALL TILE: OVER GYPSUM WALLBOARD ON WOOD OR METAL STUDS INSTALL IN ACCORDANCE 1 COAT OPEN GRAIN WOOD FILLER WITH TCA HANDBOOK METHOD W243, THIN -SET WITH DRY -SET OR LATEX-PORTLAND CEMENT 2 COATS WOOD SATIN POLYURETHANE SEALER BOND COAT, UNLESS OTHERWISE INDICATED, 7. INTERIOR HOLLOW METAL FRAMES AND DOORS 8. WALL TILE: OVER L 0 E INTERIOR CONCRETE AND MASONRY M INSTALL IN ACCORDANCE WITH TCA 1 COAT FACTORY PRIME COAT 626 YAL HANDBOOK METHOD W202, THIN -SET WITH DRY -SET OR LATEX-PORTLAND CEMENT BOND 2 COATS SPREAD LUSTER SEMI -GLOSS ENAMEL 626 BES COAT, 8. SEE ROOM FINISH SCHEDULE FOR SPECIFIC COLORS. 9. CLEAN_ TILE AND GROUT SURFACES. . DIVISION 10 - SPECIALTIES SECTION - 09.51.23 - ACOUSTIC TILE CEILINGS 689 DOR SECTION 10.21.13 - TOILET COMPARTMENTS US32D ROC 1. INTERIOR ACOUSTIC CEILING TO BE 5/8" x 24" x 48" STANDARD FISSURE TILE IN 15 16" / DCRM ROC WHITE GALVANIZED SUSPEND GRID. INSTALL PER MANUFACTURERS REQUIREMENTS. 1. MANUFACTURER: GLOBAL PARTITIONS. GRAY ROC SECTION 09.65.19 - RESILIENT TILE FLOORING 2. TYPE: STEEL SHEETS WITH POWDER -COATED FINISH: MILL-PHOSPHATIZED, CORROSION RESISTANT STEEL SHEET; STRETCHER -LEVELED FLATNESS 591M CLASS , ASTM A 591 A / C, OR GPZ NAT ASTM A 653/A 653; WITH MFR STANDARD POWDER -COATED FINISH. COLOR -GREY 2125, 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE SUPPLIERS BELOW FOR FURNISHING AND INSTALLING THE VINYL PRODUCTS AS SPECIFIED ON THE "INTERIOR FINISH SCHEDULES." FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER 3. COMPARTMENT STYLE: OVERHEAD BRACED AND FLOOR ANCHORED. URINAL SCREEN: FLOOR 26D STA INFORMATION, CALL THE APPROPRIATE SUPPLIER FOR THE AREA THE STORE IS LOCATED IN. ANCHORED. 626 BES A. MATS INC. AT (781) 573-0292• 4. DOORS: MIN 24" WIDE FOR STANDARD TOILET COMPARTMENTS AND 32" CLEAR OPENING COMPARTMENTS FOR ACCESSIBLE STALLS. 689 DOR B. INTERFACE SERVICES AT (508) 523-1859. 5. DOOR HARDWARE: CLEAR ANODIC ALUMINUM OR CAST -ZINC ALLOY. PROVIDE UNITS THAT US26D ROC COMPLY WITH ACCESSIBILITY REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. PROVIDE DCRM ROC 2. GC TO PROVIDE AND INSTALL LUXURY VINYL TILE AS SCHEDULED PER DRAWINGS. INSTALL PER U-SHAPED DOOR PULL HARDWARE ON BOTH OUT -SWING AND IN -SWING SIDE OF THE MFR REQUIREMENTS. SEE ROOM FINISH SCHEDULE FOR SPECIFIC SIZE/FINISH MATERIAL SPEC. ACCESSIBLE COMPARTMENT DOOR. MOUNT ALL OPERATING HARDWARE NO HIGHER THAN 40" GRAY ROC AFF. HARDWARE SET NO. 5; RETAIL HEALTH CENTER: 6. SELF -CLOSING HINGES: ADJUSTABLE TO HOLD DOOR OPEN AT ANY ANGLE UP TO 90 2 EA. HINGE, 4-1/2, STD. WT. CB179NRP 4-1/2 X 4-1/2 26D STA 4. GC TO CONDUCT RH MOISTURE TEST ON NEW AND EXISTING LUXURY VINYL TILE. DEGREES. 1 EA. CYLINDRICAL LOCK WITH 93K-7-D-15-D-S3 X L/C 626 BES 7. LATCHES: CONCEALED WITH DESIGNED FOR EMERGENCY ACCESS AND ADA LEVER HANDLE.. THRU BOLTS SECTIONS 09.68.13 - TILE CARPETING 1 EA. CYLINDER CORE 1CC-0BP (COAST. CORE BLACK PLASTIC) 1 8. ACCESSORIES: PROVIDE BRACKETS, PILASTER SHOES, BRACING, AND OTHER COMPONENTS 3 EA. SILENCER 608 GRAY ROC 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE SUPPLIERS REQUIRED FOR A COMPLETE INSTALLATION. 1 EA. OVERHEAD DOOR HOLDER 7 _ 04H SP28 G J BELOW FOR FURNISHING AND INSTALLING THE VINYL PRODUCTS AS SPECIFIED ON THE "INTERIOR FINISH SCHEDULES." FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER INFORMATION, CALL THE APPROPRIATE SUPPLIER FOR THE AREA THE STORE IS LOCATED IN, 9. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR REVIEW/APPROVAL. 1 EA, DOOR VIEWER 622 (UL LISTED ._WIDE ANGLE) DORM ROC A. MATS INC. AT (781) 573-0292. 10. GRAB BAR REINFORCEMENT: PROVIDE CONCEALED INTERNAL REINFORCEMENT FOR GRAB BARS HARDWARE SET NO. 7: TRAFFIC DOOR RETAIL TO RECEIVING: MOUNTED ON UNITS OF SIZE AND MATERIAL ADEQUATE FOR PANEL TO WITHSTAND APPLIED ALL HARDWARE BY DOOR MANUFACTURER. DOWNWARD LOAD ON GRAB BAR OF AT LEAST 250LBF WHEN TESTED ACCORDING TO ASTM F B. INTERFACE SERVICES AT (508) 523-1859, 446, WITHOUT DEFORMATION OF PANEL. DIVISION 08 - GLAZING SECTION 0$.80.00 -GLAZING 2. CARPET TILE SHALL BE INTERFACE GRAPHLAR TILE - NEEDLEPUNCH CONSTRUCTION. INSTALL SECTION 10.28.00 - TOILET ACCESSORIES IN 1/4 TURN PATTERN. 1. PROVIDE ALL LABOR AND MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH GRAINGER3. ALL WORK ASSOCIATED WITH GLAZING PER ASTM 1172 FOR LAMINATED GLASS AND ASTM E FOAM BACKER CARPET TILE SHALL BE INTERFACE CUSHIONBAC PLUS TILE - TUFTED INDUSTRIAL SUPPLY. SUPPLY AND COMPLETE INSTALLATION SHALL BE BY THE CONTRACTOR. 2190 FOR INSULATING GLASS. (CONTINUED) TEXTURED LOOP SEND ORDERS VIA EMAIL TO CVS@GRAINGER.COM. FOR FURTHER INFORMATION, PLEASE CALL MARK CASTONGUAY OF GRAINGER AT (774) 274-2729. 2. PROVIDE 1" INSULATED GLASS AS INDICATED ON THESE DRAWINGS WITH DUAL SEALS AND 4. INSTALL ALL CARPET MATERIALS PER MFR. REQUIREMENTS MANUFACTURER'S STANDARD SPACER MATERIAL .AND CONSTRUCTION. 2. PROVIDE ALL TREATED WOOD BLOCKING AND HARDWARE AS REQUIRED. SECTION 09.71.00 - WATERPROOF WALL PANELS 3. PROVIDE 1/4" LAMINATED GLASS AS INDICATED ON THESE DRAWINGS WITH POLYVINYL 3. REFER TO THE DRAWINGS FOR SCHEDULE OF ITEMS. MOUNT ALL ITEMS TO MEET ADA BUTYRAL INTERLAYER TO COMPLY WITH INTERLAYER MANUFACTURER'S WRITTEN INSTRUCTIONS. 1. GC TO PROVIDE AND INSTALL WATERPROOF WALL PANELS WHERE SHOWN ON THE DRAWINGS REQUIREMENTS. AND AS NEEDED FOR COMPLETE AND PROPER INSTALLATION. SECTION 10.44.00 - PORTABLE FIRE EXTINGUISHERS DIVISION 09 -FINISHES SECTION 09.29.00 - GYPSUM BOARD 2. MANUFACTURER: MARLITE: 202 HARGER STREET, DOVER, OH. 44622, ASD TEL: (330) 343-6621, FAX: (330) 343-7296 1. PROVIDE FIRE EXTINGUISHERS OF TYPE SIZE AND CAPACITY FOR EACH LOCATION INDICATED. 1. PROVIDE AND INSTALL GYPSUM DRYWALL AS INDICATED ON THESE DRAWINGS, AND PER ASTM C11 OR GA-505 BY 7H£ GYPSUM. ASSOCIATION. 3. WALL PANELS: 2. INSTALL 1N LOCATIONS AND AT MOUNTING HEIGHTS ACCEPTABLE TO AUTHORITIES HAVING . ! A. MARLITE FRP (FIBER REINFORCED PANELS) PANELS: JURISDICTION. 1. PROVIDE 5/8" GYPSUM BOARD AS INDICATED ON THESE DRAWINGS; AS MANUFACTURED BY B. SIZE: 4' - 0" X 8' - 0". 3. PROVIDE MANUFACTURER'S STANDARD STEEL BRACKETS FOR EXTINGUISHERS. DOMTAR GYPSUM AMERICA, INC., GOLD BOND BLDG. PRODUCTS, AND US GYPSUM CO. C. SHEET THICKNESS: 3/32 (2.4MM) NOMINAL. 2. GYPSUM BOARD INSTALLATION WILL BE ON METAL STUDS OR FURRING ® 16" ON CENTER D. COLOR: P100 WHITE. E. FINISH TEXTURE: PEBBLE SURFACE, 4. MULTIPURPOSE DRY-CHEMICIAL TYPE: UL-RATED 4-A: 60-B: C, 10-16 NORMAL CAPACITY IN ENAMELED -STEEL CONTAINERS. UNLESS OTHERWISE NOTED. ADJUST GAUGE AS REQUIRED FOR UNSUPPORTED LENGTH PER 5 PSF. FOR LOADING REFER TO THE DRAWINGS FOR MINIMUM GAUGE. 4. TRIM: MATCHING MARLITEOMOLDING TRIM AS SUPPLIED BY PANEL MANUFACTURER FOR SECTION 10.44.00 - FIRE PROTECTION SPECIALTIES 3, INSTALL WATER RESISTANT GYPSUM BOARD, PER. ASTM C30 AT TOILETS, SERVICE SINK, ALL OUTSIDE/INSIDE CORNERS, VERTICAL JOINTS, OPENINGS, OUTSIDE ANGLES, END CAPS, AND CEILING INTERSECTIONS. 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE SINKS AND FLOOR DRAIN AREAS. MANUFACTURERS LISTED BELOW TO FURNISH AND INSTALL THE FIRE ALARM SYSTEM 5. FASTENERS: MANUFACTURER'S STANDARD RIVETS. SPECIFIED 1N THIS SECTION. COMPLETE INSTALLATION SHALL BE BY THE NATIONAL 4. PROVIDE MANUFACTURER'S STANDARD TRIM ACCESSORIES, INCLUDING BUT NOT LIMITED TO ACCOUNT SUPPLIER. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE CORNER BEAD, L TYPE EDGES, TRIM BEDS, U TYPE EDGE TRIM BEAD, SPECIAL L CURVED TYPE MANUFACTURER FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER EDGE TRIM BEAD AND ONE PIECE CONTROL JOINT BEAD. 6. ADHESIVE: NON-FLAMMABLE ADHESIVE AS RECOMMENDED BY THE MANUFACTURER FOR INFORMATION, PLEASE CALL THE APPROPRIATE MANUFACTURER FOR THE AREA THE SUBSTRATE ENCOUNTERED. STORE IS LOCATED IN. 5. PROVIDE CONTROL JOINTS IN WALLS AT NOT MORE THAN 30' SPACING AND IN SOFFITS NOT EXCEEDING 50' SPACING, OR AS INDICATED ON THE DRAWINGS. 7. SEALANT: AS RECOMMENDED BY PANEL MANUFACTURER. A. BASS SECURITY AT (888) 774-3400 AT EXT. 1950 AREAS: IL, IN, MI, OH B. AFA PROTECTIVE SYSTEM AT (781) 848-6200 AREAS: AL, FL, GA, MA, ME, NC, NH, NY, 6. FINISH PANELS TO LEVEL 4 ACCORDING TO ASTM C 840: ALL JOINTS AND INTERIOR ANGLES 8. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE PA, RI, SC, VT SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND THREE SEPARATE COATS OF JOINT AND PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR, SUBJECT TO THE APPROVAL OF THE ARCHITECT. C. TECHONOCALITY AT 646 723-4410 AREAS: CT, DC, DE MD ( ) COMPOUND APPLIED OVER ALL JOINTS, ANGLES, FASTENER HEADS, AND ACCESSORIES. THE SURFACE SHALL BE SMOOTH AND FREE OF TOOL MARKS AND RIDGES, THIS FINISH IS TO BE D. INTEGRATED SECURITY SOLUTIONS AT (800) 505-0868 AREA: NJ APPLIED IN ALL AREAS UNLESS NOTED OTHERWISE. OMIT THIRD COAT AND SANDING ON ( 9. INSTALLATION TON OF PANELS SHALL BE IN STRICT ACCORDANCE WITH. THE. MANUFACTURER'S E. VECTOR SECURITY AT 703 ( ) 468 6100 AT EXT. 51126 AREA: AK, CA, CO, HI, ID, IL, IN, CONCEALED DRYWALL WORK) RECOMMENDATIONS. PROMPTLY, UPON COMPLETION OF INSTALLATION CLEAN ALL EXPOSED KY, 'MI, MT; NM, NV, OH, OR, PR, TN, UT, VA, WA WV WY SURFACES WITH METHODS AND MATERIALS RECOMMENDED BY THE MANUFACTURER OF THE F. ADVANCED PROJECT SOLUTIONS, LLC AT (608) 204-8640 AREA: AR, IA, KS, MO, MS, ND, 7. EXTERIOR GYPSUM SHEATHING - 5/8" DENS -GLASS GOLD PER ASTM, C79. PANELS. NE, OK, SD, WI 8. USE METAL CORNER BEADS ON ALL GYPSUM BOARD EXTERIOR CORNERS SECTION 09.72.00 - WALL COVERINGS 2. GENERAL: NONCODED, ZONED SYSTEM WITH MANUAL AND AUTOMATIC ALARM INITIATION; AND 1. CVS/PHARMACY HAS ENTERED INTO AN AGREEMENT WITH WOLF GORDON FOR FURNISHING THE HARD -WIRED FOR SIGNAL TRANSMISSION, USING SEPARATE INDIVIDUAL CIRCUITS FOR EACH WALL COVERING AS SPECIFIED IN THIS SECTION. COMPLETE INSTALLATION SHALL BE BY THE ZONE OF ALARM INITIATION AND NOTIFICATION APPLIANCES. 9. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS OR CONTRACTOR. FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER INFORMATION CALL STOPPING SHORT OF OTHER MATERIALS TO FORM A REVEAL OR RECESS. WOLF GORDON AT (800) 347-0550. 3. INSTALLER QUALIFICATIONS: AN EXPERIENCED INSTALLER WHO IS AN AUTHORIZED 2. GC TO PROVIDE AND INSTALL ALL WALL COVERINGS AS SHOWN ON DRAWINGS AND AS NEEDED REPRESENTATIVE OF THE FACP MANUFACTURER FOR BOTH INSTALLATION AND MAINTENANCE SECTION - 09.30.00 - TILING FOR COMPLETE AND PROPER INSTALLATION PER MFR, REQUIREMENTS OF UNITS REQUIRED FOR THIS PROJECT. 3. SEE FINISH SCHEDULE FOR MATERIAL/MANUFACTURER INFORMATION 1. FLOOR AND WALL GLAZED CERAMIC TILE SHALL BE 5/16" THICK OF UNIT TYPES, SIZES, AND 4, MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN MANUFACTURING SYSTEMS SIMILAR COLORS INDICATED IN FINISH SCHEDULE, AS MANUFACTURED BY DALTILE, PROVIDE SECTION 09.90.00 - PAINTING TO THOSE INDICATED FOR THIS PROJECT AND WITH A RECORD OF SUCCESSFUL IN-SERVICE MANUFACTURER'S STANDARD TRIM UNITS, INCLUDING BULLNOSE AND COVED BASE, AS PERFORMANCE. SCHEDULED. 1. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERE INDICATED ON ROOM FINISH: SCHEDULE PAINT BEHIND ALL MOVEABLE ITEMS ADJAC ENT TO 5. COMPLIANCE WITH LOCAL REQUIREMENTS: COMPLY WITH APPLICABLE BUILDING CODE, LOCAL 2. MORTAR BOND COAT MATERIALS: WALLS RECEIVING PAINT AND RELOCATE ITEMS, ORDINANCES AND REGULATIONS, AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. A. DRY -SET PORTLAND CEMENT TYPE: ANSI A118.1. 2. PROVIDE ALL LABOR AND MATERIALS AS NECESSARY FOR FINISHES AS INDICATED IN THESE 6. COMPLY WITH NFPA 72. B. LATEX-PORTLAND CEMENT TYPE: ANSI A118.4. SPECIFICATIONS. C. EPDXY: ANSI A118.3, 100 PERCENT SOLIDS. 7. FURNISH EXTRA MATERIALS DESCRIBED BELOW THAT MATCH PRODUCTS INSTALLED AND THAT 3. ACCEPTABLE PAINT MANUFACTURERS INCLUDE: SHERWIN WILLIAMS, PPG, AND BENJAMIN ARE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS 3. STANDARD GROUT: CEMENT GROUT, SANDED OR UNSANDED, AS SPECIFIED IN ANSI A118.6; MOORE DESCRIBING CONTENTS COLOR AS SELECTED, 1/8" GROUT JOINTS, TYPICAL. 4. ALL FINISHES AND MATERIALS TO RECEIVE PAINT SHALL BE CLEANED THOROUGHLY AND A. SMOKE DETECTORS, FIRE DETECTORS, AND FLAME _DETECTORS: QUANTITY EQUAL TO 10 4. LAY TILE TO PATTERN INDICATED. PREPARED PER MANUFACTURES RECOMMENDATIONS. B. PERCENT OF AMOUNT, OF EACH TYPE INSTALLED, BUT NOT LESS THAN ONE UNIT OF r MOTAI I TII C, AAIn /lnlV IT IAI A(IflnnnAKIhr IAl-I A-1 ­11 1 ­,�,��,.�.,,-� ,.� ..,�, ..,... C. EACH TYPE. F. KEYS AND TOOLS: ONE EXTRA SET FOR ACCESS TO LOCKED AND TAMPERPROOFED BE BY THE CONTRACTOR. FOR PRICING QUOTATIONS, PLACING ORDERS; AND FURTHER INFORMATION, PLEASE CALL THE APPROPRIATE MANUFACTURER FOR THE AREA THE STORE IS 8. COMPONENTS. LOCATED IN. ATLAS SIGNS AT (561) 863-6659, CONTACT ANNETTE SOUTHERN 15. EQUIPMENT INSTALLATION: AREAS: AL, IN, KY, MI, MS, OH, TN, WV CHANDLER AT (214) 902-2000 EXT, 6528, CONTACT WALTER FINNINGER ' OR DOUG HALLAM A. CONNECT THE FACP WITH A CIRCUIT BREAKER WITH LOCKABLE HANDLE OR COVER. AREAS: AR, KS, LA, MO, OK, TX B. MANUALACT PULL STATIONS: IONS: MOUNT SEMIFLUSH IN RECESSED BACK BOXES. COAST SIGNS - AT 714 61 5 3141 CONTACT ERNI E RIVA ( ) S C. WATER -FLOW DETECTORS AND VALVE SUPERVISORY SWITCHES: ,CONNECT FOR EACH AREAS: CENTRAL CA SPRINKLER VALVE STATION REQUIRED TO BE SUPERVISED. SUPPLIED AND INSTALLED BY SPRINKLER CO TRACTOR. FLOURESCO LIGHTING & SIGNS AT (909) 647-8588, CONTACT RON HILL AREAS: AZ, SOUTHERN CA, NV D. CEILING- MOUNTED THE NEAR EDGE SMOKE DETECTORS: NOT LESS THAN 4 INCHES FROM A SIDE WALL TO FOR EXPOSED SOLID -JOIST CONSTRUCTION, MOUNT DETECTORS ON THE ICON IDENTITY SOLUTIONS AT (727) 373-2033, CONTACT JON ALLEN BOTTOM OF JOISTS, ON SMOOTH CEILINGS, INSTALL NOT MORE THAN 30 FEET APART IN AREAS: NORTHERN CA, CO, HI, IA, ID, IL, MN, MT, ND, NE, NM, OR, SD, UT, WA, WI, WY ANY DIRECTION. IMAGE ONE AT (215) 826-0880, CONTACT PAUL SILVER E. WALL -MOUNTED SMOKE DETECTORS: AT LEAST 4 INCHES, BUT NOT MORE THAN 12 AREAS: NJ INCHES, BELOW THE CEILING. F. SMOKE DETECTORS NEAR AIR REGISTERS: INSTALL NO CLOSER THAN 60 INCHES. POYANT SIGNS AT (508) 995-1777 EXT. 133, CONTACT NATALIA PELLETIER G. DUCT SMOKE DETECTORS: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AREAS: CT; MA, ME, NH; RI, VT H VERIFY THAT EACH UNIT IS LISTED FOR THE COMPLETE RANGE OF AIR VELOCITY, SERVICE NEON - AT (703) 354 3000, CONTACT RICK PEPPER TEMPERATURE, AND HUMIDITY POSSIBLE WHEN AIR -HANDLING SYSTEM IS OPERATING. AREAS: DC, DE, MD, SC, VA I. INSTALL SAMPLING TUBES SO THEY EXTEND THE FULL WIDTH OF THE DUCT. SIGN ENGINEERING AT (787) 790-1330, CONTACT IXIA RIOS AT EXT. 235 J. AUDIBLE ALARM -INDICATING DEVICES: INSTALL NOT LESS THAN 6 INCHES BELOW THE AREAS: PR CEILING_ INSTALL BELLS AND HORNS ON FLUSH -MOUNTED BACK BOXES WITH THE ULTIMATE SIGNS AT (516)481-0800, CONTACT ARLENE MELT DEVICE OPERATING MECHANISM CONCEALED BEHIND A GRILLE. COMBINE AUDIBLE AND VISIBLE ALARMS AT THE SAME LOCATION INTO A SINGLE UNIT, AREAS: NYC ONLY K. VISIBLE ALARM -INDICATING DEVICES: INSTALL AT 80'AFF OR 6 INCHES BELOW THE WALTON SIGNS AT (210) 906-5986, CONTACT MARISOL JUAREZ CEILING, WHICHEVER IS LOWER. AREAS: AK, NORTHERN FL, GA L. DEVICE LOCATION -INDICATING LIGHTS: LOCATE IN PUBLIC SPACE NEAR THE DEVICE THEY MONITOR. 11. CONTRACTOR SHALL ENTER INTO A CONTRACT WITH THE SIGN COMPANY CHOSEN BY THE M. FACP: SURFACE MOUNT WITH TOPS OF CABINETS NOT MORE THAN 72 INCHES ABOVE THE OWNER FOR INSTALLATION OF PYLON SIGN; DRIVE-THRU SIGNS, AND BUILDING SIGNS. FINISHED FLOOR. N. ANNUNCIATOR: INSTALL WITH THE TOP OF THE PANEL NOT MORE THAN 72 INCHES ABOVE 12. LOCATE SIGN UNITS AND ACCESSORIES WHERE INDICATED OR REQUIRED, USING MOUNTING THE FINISHED FLOOR. METHODS COMPLYING WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 16. WIRING INSTALLATIOI DIVISION 11 EQUIPMENT - - NOT USED A. WIRING METHOD: INSTALL WIRING AS REQUIREDBY NFPA 70, ARTICLE 760. CONCEAL DIVISION 12 - FURNISHINGS RACEWAY EXCEPT IN UNFINISHED SPACES AND AS. INDICATED. B. WIRING WITHIN ENCLOSURES: SEPARATE POWER -LIMITED AND NON -POWER -LIMITED CONDUCTORS AS RECOMMENDED BY THE MANUFACTURER. INSTALL CONDUCTORS PARALLEL - SECTION 12.24,00 ROLLER WINDOW SHADES WITH OR AT RIGHT ANGLES TO SIDES AND BACK OF THE ENCLOSURE, BUNDLE, LACE, AND 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH ROLL -A -SHADE TRAIN CONDUCTORS TO TERMINAL POINTS WITH NO EXCESS, CONNECT CONDUCTORS THAT FOR FURNISHING THE ROLLER WINDOW SHADES SPECIFIED IN THIS SECTION. SYSTEM SHALL ARE TERMINATED, SPLICED, OR INTERRUPTED IN ANY ENCLOSURE ASSOCIATED WITH THE BE SUPPLIED BY THE GENERAL CONTRACTOR AND COMPLETE INSTALLATION SHALL BE BY THE FIRE ALARM SYSTEM TO TERMINAL BLOCKS. MARK EACH TERMINAL ACCORDING TO THE MANUFACTURER UNDER CONTRACT WITH THE GENERAL CONTRACTOR. FOR PRICING SYSTEM'S WIRING DIAGRAMS. MAKE ALL CONNECTIONS WITH APPROVED CRIMP -ON QUOTATIONS, PLACING ORDERS, AND FURTHER INFORMATION, CALL ROLL -A -SHADE AT (951) TERMINAL SPADE LUGS, PRESSURE -TYPE TERMINAL BLOCKS, OR PLUG CONNECTORS, 245-5077 EXT, 111. C. CABLE TAPS: USE NUMBERED TERMINAL STRIPS IN JUNCTION, PULL AND OUTLET BOXES, CABINETS, OR EQUIPMENT ENCLOSURES WHERE CIRCUIT CONNECTIONS ARE MADE. 2. RELATED REQUIREMENTS: SECTION 06.10.00 "ROUGH CARPENTRY" FOR WOOD BLOCKING AND D. COLOR -CODING: COLOR -CODE FIRE ALARM CONDUCTORS DIFFERENTLY FROM THE NORMAL GROUNDS FOR MOUNTING ROLLER SHADES AND ACCESSORIES, SECTION 09.29.00 "GYPSUM BUILDING POWER i WIRING. USE ONE COLOR -CODE FOR ALARM CIRCUIT WIRING AND A DIFFERENT COLOR -CODE FOR SUPERVISORY CIRCUITS, COLOR -CODE AUDIBLE BOARD" FOR COORDINATION WITH GYPSUM BOARD ASSEMBLIES FOR INSTALLATION OF SHADE ALARM -INDICATING CIRCUITS DIFFERENTLY FROM ALARM -INITIATING CIRCUITS. USE POCKETS, CLOSURES AND RELATED ACCESSORIES AND DIVISION 16 "ELECTRICAL" FOR DIFFERENT COLORS FOR VISIBLE ALARM -INDICATING DEVICES. PAINT FIRE ALARM SYSTEM ELECTRIC SERVICE FOR MOTOR CONTROLS. JUNCTION BOXES AND COVERS RED. 3. INSTALLER QUALIFICATIONS: INSTALLER TRAINED AND CERTIFIED BY THE MANUFACTURER WITH 17. IDENTIFICATION: A MINIMUM OF TEN YEARS OF EXPERIENCE IN INSTALLING PRODUCTS COMPARABLE TO THOSE SPECIFIED IN THE SECTION. A. IDENTIFY SYSTEM COMPONENTS, WIRING; CABLING, AND TERMINALS ACCORDING TO DIVISION 16 SECTION "BASIC ELECTRICAL MATERIALS AND METHODS." 4. ENVIRONMENTAL LIMITATIONS: DO NOT INSTALL ROLLER SHADES- UNTIL CONSTRUCTION AND FINISH WORK IN SPACES, INCLUDING PAINTING, IS COMPLETE AND DRY AND AMBIENT B. IDENTIFY SYSTEM COMPONENTS, WIRING, CABLING, AND TERMINALS ACCORDING TO DIVISION TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR 16 SECTION "ELECTRICAL IDENTIFICATION." PROJECT WHEN OCCUPIED FOR ITS INTENDED USE. C. INSTALL INSTRUCTIONS FRAME IN A LOCATION VISIBLE FROM THE FACP. D. PAINT POWER -SUPPLY CIRCUIT BREAKER RED AND LABEL "FIRE ALARM." 5. FIELD MEASUREMENTS: WHERE ROLLER SHADES ARE INDICATED TO FIT TO OTHER CONSTRUCTION, VERIFY DIMENSIONS OF OTHER CONSTRUCTION BY FIELD MEASUREMENTS 18. GROUNDING: BEFORE FABRICATION AND INDICATE MEASUREMENTS ON SHOP DRAWINGS. ALLOW CLEARANCES FOR OPERATING HARDWARE OF OPERABLE GLAZED UNITS THROUGH ENTIRE OPERATING RANGE. NOTIFY ARCHITECT OF INSTALLATION CONDITIONS THAT VARY FROM DRAWINGS. COORDINATE A. GROUND CABLE SHIELDS AND EQUIPMENT ACCORDING TO SYSTEM MANUFACTURER'S FABRICATION SCHEDULE WITH CONSTRUCTION PROGRESS TO AVOID DELAYING THE WORK. WRITTEN INSTRUCTIONS TO ELIMINATE SHOCK HAZARD AND TO MINIMIZE, TO THE GREATEST EXTENT POSSIBLE, GROUND LOOPS, COMMON` MODE RETURNS, NOISE PICKUP, CROSS TALK, 6. BASIS .OF DESIGN: ROLL -A -SHADE, AND OTHER IMPAIRMENTS. A. AS-1: MOTORIZED INTERIOR SUNSCREEN ROLLER SHADES AT RETAIL SECTION. 19. FIELD QUALITY CONTROL: B. RAS-2: MANUAL INTERIOR SUNSCREEN ROLLER SHADES AT VESTIBULE. A. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE 7. ACCESSORIES B. REPRESENTATIVE TO INSPECT FIELD -ASSEMBLED COMPONENTS AND CONNECTIONS AND TO SUPERVISE PRETESTING, TESTING, AND ADJUSTMENT OF THE SYSTEM. REPORT RESULTS IN WRITING. A. SUN SENSOR ONE PER ELEVATION. SUN SENSOR TO BE PLUG-IN PROVIDED WITH NEMA C. PRETESTING: AFTER INSTALLATION, ALIGN, ADJUST, AND BALANCE THE SYSTEM AND PLUG. BATTERY OPERATED NOT PERMITTED. PERFORM COMPLETE PRETESTING. DETERMINE; THROUGH PRETESTING, THE COMPLIANCE OF B. 3 CHANNEL WALL SW L SW ITCH -.SEE PLANS FOR LOCATION, WALL SWITCH TO BE PLUG-IN THE SYSTEM WITH REQUIREMENTS OF DRAWINGS AND SPECIFICATIONS, CORRECT PROVIDED WITH PLUG. BATTERY OPERATED NOT PERMITTED. DEFICIENCIES OBSERVED IN PRETESTING. REPLACE MALFUNCTIONING OR DAMAGED ITEMS C. 5 CHANNEL WIRELESS REMOTE (OPTIONAL). WITH NEW ONES, AND RETEST UNTIL SATISFACTORY PERFORMANCE AND CONDITIONS ARE ACHIEVED. PREPARE FORMS FOR SYSTEMATIC RECORDING OF ACCEPTANCE TEST RESULTS. D. REPORT OF PRETESTING: AFTER PRETESTING IS COMPLETE, PROVIDE A LETTER g DO NOT BEGIN INSTALLATION UNTIL SUBSTRATES HAVE BEEN PROPERTY PREPARED.lF SUBSTRATE PREPARATION IS THE RESPONSIBILITY OF ANOTHER INSTALLER, NOTIFY E. CERTIFYING THE INSTALLATION IS COMPLETE AND FULLY OPERABLE, INCLUDING THE NAMES ARCHITECT CONTRACTOR OF ANY UNSATISFACTORY PREPARATION BE FORE EFORE PROCEEDING. AND TITLES OF WITNESSES TO PRELIMINARY TESTS. F. FINAL TEST NOTICE: PROVIDE A MINIMUM OF 10 DAYS' NOTICE IN WRITING WHEN THE SYSTEM IS READY FOR FINAL ACCEPTANCE TESTING, A. INSTALL ROLLER SHADES LEVEL, PLUMB, AND TRUE. ALLOW PROPER CLEARANCES FOR WINDOW OPERATION HARDWARE. G. MINIMUM SYSTEM TESTS: TEST THE SYSTEM ACCORDING TO PROCEDURES OUTLINED IN B. CONTRACTOR SHALL PROVIDE POWER PANELS AND CIRCUITS OF SUFFICIENT SIZE TO NFPA 72: ACCOMMODATE ROLLER SHADE MANUFACTURER'S REQUIREMENTS. H. RETESTING: CORRECT DEFICIENCIES INDICATED BY TESTS AND COMPLETELY RETEST WORK C. CONTRACTOR SHALL COORDINATE LOCATION OF POWER SUPPLY FOR ROLLER SHADES WITH AFFECTED BY SUCH DEFICIENCIES. VERIFY BY THE SYSTEM TEST THAT THE TOTAL SYSTEM MANUFACTURER. MEETS SPECIFICATIONS AND COMPLIES WITH APPLICABLE STANDARDS. I. REPORT OF TESTS AND INSPECTIONS: PROVIDE A WRITTEN RECORD OF INSPECTIONS, D. CONTRACTOR SHALL SUPPLY ONE (1) SURFACE MOUNTED DUPLEX AT UNDERSIDE OF TESTS, AND DETAILED TEST RESULTS IN THE FORM OF A TEST LOG. SUBMIT LOG ON THE SOFFIT FOR EACH ELEVATION WITHIN 6' OF WINDOW SIDES. SATISFACTORY COMPLETION OF TESTS. E. ADJUST AND BALANCE ROLLER SHADES TO OPERATE SMOOTHLY, EASILY AND FREE FROM BINDING. 20. CLEANING: REMOVE PAINT SPLATTERS AND OTHER SPOTS, DIRT, AND DEBRIS. TOUCH UP F. CLEAN ROLLER SHADE SURFACES AFTER INSTALLATION, ACCORDING TO MANUFACTURER'S SCRATCHES AND MARRED FINISH TO MATCH ORIGINAL FINISH. CLEAN UNIT INTERNALLY USING WRITTEN INSTRUCTIONS. METHODS AND MATERIALS RECOMMENDED BY MANUFACTURER. G. ENGAGE INSTALLER TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE AND MAINTAIN ROLLER SHADE SYSTEMS. 21. DEMONSTRATION: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN H. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT. OWNER'S MAINTENANCE PERSONNEL AS SPECIFIED BELOW: !. TOUCH-UP REPAIR AND/OR REPLACE ANY DAMAGED PRODUCTS BEFORE SUBSTANTIAL COMPLETION. A. TRAIN OWNER'S M INTENAACE PERSONNEL ON PROCEDURES AND SCHEDULES FOR STARTING AND STOPPING, TROUBLESHOOTING, SERVICING, ADJUSTING, AND MAINTAINING EQUIPMENT SECTION 12,30.00 - STEEL GONDOLAS (IF NO STORE SET-UP) AND SCHEDULES. PROVIDE A MINIMUM OF 8 HOURS' TRAINING: B. TRAINING AID: USE THE APPROVED FINAL VERSION OF THE OPERATION AND 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE MAINTENANCE MANUAL AS A TRAINING AID. SCHEDULE TRAINING. WITH OWNER, THROUGH ARCHITECT, WITH AT LEAST SEVEN DAYS' ADVANCE NOTICE. MANUFACTURERS BELOW FOR FURNISHING THE. STEEL GONDOLAS IN THIS SECTION. COMPLETE INSTALLATION SHALL BE BY THE CONTRACTOR. FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER INFORMATION, PLEASE CALL THE APPROPRIATE MANUFACTURER FOR THE AREA 22. ON -SITE ASSISTANCE THE STORE IS LOCATED IN: A. OCCUPANCY ADJUSTMENTS: WHEN REQUESTED WITHIN ONE Q YEAR OF DATE OF A - A. LOZIER STORE FIXTURE INC. AT 574 825 9561. AREAS: AL ( ) AR, IA, IL, IN, KY, LA,MD, MI, SUBSTANTIAL COMPLETION, PROVIDE ON -SITE ASSISTANCE IN ADJUSTING SOUND LEVELS, MN, MO, MS, OH, SD, TN, WI, WV, WY CONTROLS, AND SENSITIVITIES TO SUIT ACTUAL OCCUPIED CONDITIONS. PROVIDE UP TO B. MADIX STORE FIXTURES INC. AT (203) 975-7403. AREAS: AK, AR, AZ, CA, HI, IA, ID, LA, THREE REQUESTED VISITS TO PROJECT SITE FOR THIS PURPOSE.MA MN, MT, ND, NM, NV, SD, TX, WY SECTION 10,70.00 - EXTERIOR SIGNS 2. INSTALLER QUALIFICATIONS: ENGAGE AN EXPERIENCED INSTALLER WHO IS AN AUTHORIZED lf*CV,S pharmacy" RESET STORE NUMBER: 00944 453 STATION AVENUE SOUTH' YARMOUTH, MA 02664 CAP CODE: 00072 CS PROJECT NUMBER: 163445 STARCK ARCHITECTS 126 Cove Street Fall River, MA 02720 1 Richmond Square, Suite 120C Providence, RI 02903 MA 508.679.5733 RI401,709.7799 STRRC KARCH ITECTS.COM CONSULTANT ENGINEER CONSULTANT: SEAL: R RED ARC \ .951251 OF REVISIONS: DRAWING/REVIEWED BY: PPY/MJT CVS PROJECT MANAGER: SH DATE: 08/08/2022 JOB NUMBER: 163445 TI TLE: SPECIFICATIONS SHEET NUMBER: G361 I^ nNA NA F NI Tq, -