Loading...
HomeMy WebLinkAbout453 Station Ave CVS plan 5z Q LC) cal N 0 N 03 DOOR HARDWARE SCHEDULE HARDWARE SET NO. 2; MANAGER'S OFFICE, EMPLOYEE, AND TOILET ROOMS: 3 EA. HINGE, 4-1/2, STD. WT. C8179NRP 4-1/2 X 4-1/2 1 EA. CYLINDRICAL LOCK WITH 93K-7-D-15-D-S3 X L/C THRU BOLTS 1 EA. CYLINDRICAL LOCK WITH B-AU-NTB620NR THRU BOLTS 1.3/4" X LC X 694 X 497 (1-1/4 LIP) X 380AN (EMPLOYEE ONLY) 1 EA. PRIVACY LOCK WITH 93K-0-L-15-D-S3 (TOILET ROOMS ONLY) THRU BOLTS 1 EA. CYLINDER CORE 1CC-OBP (CONST. CORE BLACK PLASTIC) (MNGR & EMPLOYEE ONLY) 1 EA. CLOSER 8616 ARP COV SNB1-REGULAR ARM 1 EA. WALL STOP 409 1 EA. DOOR VIEWER 622 (UL LISTED WIDE ANGLE)(MNGR ONLY) 3 EA. SILENCER 608 (EMPLOYEE & TOILET ROOMS ONLY) 1 EA. LITE (GLAZING) L-FRA100 8 W X 26 H (EMPLOYEE ONLY AND OCCASIONALLY MANAGER) HARDWARE SET NO. 3; PHARMACY: 3 EA. HINGE, 4-1/2, STD. WT. CB179NRP 4-1/2 X 4-1/2 1 EA. CYLINDRICAL LOCK WITH 93K-7-D-15-D-S3 X L/C THRU BOLTS 1 EA. CYLINDER CORE 1CC-OBP (COAST. CORE BLACK PLASTIC) 1 EA. CLOSER 8616 ARP COV SNB1 1 EA. FLOOR STOP 442 1 EA. DOOR VIEWER 622 (UL LISTED WIDE ANGLE) 3 EA. DOOR VIEWER ROCKWOOD GREY SILENCERS HARDWARE SET NO. 5 RETAIL HEALTH CENTER: 26D 626 626 626 STA BES YAL BES 689 DOR US32D ROC DCRM ROC GRAY ROC GPZ NAT 260 STA 626 BES 689 DOR US26D ROC DCRM ROC GRAY ROC 2 EA. HINGE, 4-1/2, STD. WT. CB179NRP 4-1/2 X 4-1/2 26D STA 1 EA. CYLINDRICAL LOCK WITH 93K-7-D-15-D-S3 X L/C626 BES THRU BOLTS 1 EA. CYLINDER CORE 1 CC-OBP (CONST. CORE BLACK PLASTIC) 3 EA. SILENCER 608 GRAY ROC 1 EA. OVERHEAD DOOR HOLDER 704H SP28 G-J 1 EA, DOOR VIEWER 622 (UL LISTED WIDE ANGLE) DCRM ROC HARDWARE SET NO. 7: TRAFFIC DOOR RETAIL TO RECEIVING: ALL HARDWARE BY DOOR MANUFACTURER. DIVISION 08 - GLAZING SECTION 08.80.00 - GLAZING 1. PROVIDE ALL LABOR AND MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH GLAZING PER ASTM 1172 FOR LAMINATED GLASS AND ASTM E 2190 FOR INSULATING GLASS. (CONTINUED) 2. PROVIDE 1" INSULATED GLASS AS INDICATED ON THESE DRAWINGS WITH DUAL SEALS AND MANUFACTURER'S STANDARD SPACER MATERIAL AND CONSTRUCTION. 3. PROVIDE 1/4" LAMINATED GLASS AS INDICATED ON THESE DRAWINGS WITH POLYVINYL BUTYRAL INTERLAYER TO COMPLY WITH INTERLAYER MANUFACTURER'S WRITTEN INSTRUCTIONS DIVISION 09 - FINISHES SECTION 09.29.00 - GYPSUM BOARD 1. PROVIDE AND INSTALL GYPSUM DRYWALL AS INDICATED ON THESE DRAWINGS, AND PER ASTM C11 OR GA-505 BY THE GYPSUM ASSOCIATION. 1. PROVIDE 5/8" GYPSUM BOARD AS INDICATED ON THESE DRAWINGS, AS MANUFACTURED BY DOMTAR GYPSUM AMERICA, INC., GOLD BOND BLDG. PRODUCTS, AND US GYPSUM CO. 2. GYPSUM BOARD INSTALLATION WILL BE ON METAL STUDS OR FURRING @ 16" ON CENTER UNLESS OTHERWISE NOTED. ADJUST GAUGE AS REQUIRED FOR UNSUPPORTED LENGTH PER 5 PSF. FOR LOADING REFER TO THE DRAWINGS FOR MINIMUM GAUGE. 3, INSTALL WATER RESISTANT GYPSUM BOARD, PER ASTM C30 AT TOILETS, SERVICE SINK, ALL SINKS AND FLOOR DRAIN AREAS. 4. PROVIDE MANUFACTURER'S STANDARD TRIM ACCESSORIES, INCLUDING BUT NOT LIMITED TO CORNER BEAD, L TYPE EDGES, TRIM BEDS, U TYPE EDGE TRIM BEAD, SPECIAL L CURVED TYPE EDGE TRIM BEAD AND ONE PIECE CONTROL JOINT BEAD. 5. PROVIDE CONTROL JOINTS IN WALLS AT NOT MORE THAN 30' SPACING AND IN SOFFITS NOT EXCEEDING 50' SPACING, OR AS INDICATED ON THE DRAWINGS. 6. FINISH PANELS TO LEVEL 4 ACCORDING TO ASTM C 840: ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND THREE SEPARATE COATS OF JOINT COMPOUND APPLIED OVER ALL JOINTS, ANGLES, FASTENER HEADS, AND ACCESSORIES. THE SURFACE SHALL BE SMOOTH AND FREE OF TOOL MARKS AND RIDGES. THIS FINISH. IS TO BE APPLIED IN ALL AREAS UNLESS NOTED OTHERWISE. (OMIT THIRD COAT AND SANDING ON CONCEALED DRYWALL WORK) 7. EXTERIOR GYPSUM SHEATHING - 5/8" DENS -GLASS GOLD PER ASTM. C79. 8. USE METAL CORNER BEADS ON ALL GYPSUM BOARD EXTERIOR CORNERS. 9, INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS OR STOPPING SHORT OF OTHER MATERIALS TO FORM A REVEAL OR RECESS. SECTION - 09.30.00 - TILING 1. FLOOR AND WALL GLAZED CERAMIC TILE SHALL BE 5/16" THICK OF UNIT TYPES, SIZES, AND COLORS INDICATED IN FINISH SCHEDULE, AS MANUFACTURED BY DALTILE. PROVIDE MANUFACTURER'S STANDARD TRIM UNITS, INCLUDING BULLNOSE AND COVED BASE, AS SCHEDULED. 2. MORTAR BOND COAT MATERIALS: A. DRY -SET PORTLAND CEMENT TYPE: ANSI A118.1. B. LATEX-PORTLAND CEMENT TYPE: ANSI A118.4. C. EPDXY: ANSI A118.3, 100 PERCENT SOLIDS. 3. STANDARD GROUT: CEMENT GROUT, SANDED OR UNSANDED, AS SPECIFIED IN ANSI A118.6; COLOR AS SELECTED. 1 /8" GROUT JOINTS, TYPICAL. 4. LAY TILE TO PATTERN INDICATED. 5. INSTALL TILE AND GROUT IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF ANSI A108.1 THROUGH A108.13, MANUFACTURER'S INSTRUCTIONS, AND TCA HANDBOOK RECOMMENDATIONS. 6. FLOOR TILE: OVER INTERIOR CONCRETE SUBSTRATES, INSTALL IN ACCORDANCE WITH TCA 2 COATS LATEX EGGSHELL HANDBOOK METHOD F113, DRY -SET OR LATEX-PORTLAND CEMENT BOND COAT, WITH STANDARD GROUT, UNLESS OTHERWISE INDICATED. 6. INTERIOR WOOD DOORS. 1 COAT OPEN GRAIN WOOD FILLER 7. WALL TILE: OVER GYPSUM WALLBOARD ON WOOD OR METAL STUDS INSTALL IN ACCORDANCE 2 COATS WOOD SATIN POLYURETHANE SEALER WITH TCA HANDBOOK METHOD W243, THIN -SET WITH DRY -SET OR LATEX-PORTLAND CEMENT BOND COAT, UNLESS OTHERWISE INDICATED. 7. INTERIOR HOLLOW METAL FRAMES AND DOORS 8. WALL TILE: OVER INTERIOR CONCRETE AND MASONRY INSTALL IN ACCORDANCE WITH TCA 1 COAT FACTORY PRIME COAT HANDBOOK METHOD W202, THIN -SET WITH DRY -SET OR LATEX-PORTLAND CEMENT BOND 2 COATS SPREAD LUSTER SEMI -GLOSS ENAMEL COAT. 8. SEE ROOM FINISH SCHEDULE FOR SPECIFIC COLORS. 9. CLEAN TILE AND GROUT SURFACES. DIVISION 10 - SPECIALTIES SECTION - 09.51.23 - ACOUSTIC TILE CEILINGS SECTION 10.21.13 - TOILET COMPARTMENTS 1. INTERIOR ACOUSTIC CEILING TO BE 5/8" x 24" x 48" STANDARD FISSURE TILE IN 15/16" 1. MANUFACTURER: GLOBAL PARTITIONS. WHITE GALVANIZED SUSPEND GRID. INSTALL PER MANUFACTURERS REQUIREMENTS. 2. TYPE: STEEL SHEETS WITH POWDER -COATED FINISH: MILL-PHOSPHATIZED, CORROSION SECTION 09.65.19 - RESILIENT TILE FLOORING RESISTANT STEEL SHEET; STRETCHER -LEVELED FLATNESS, ASTM A 591/A 591M, CLASS C, OR ASTM A 653/A 653; WITH MFR STANDARD POWDER -COATED FINISH. COLOR -GREY 2125. 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE SUPPLIERS BELOW FOR FURNISHING AND INSTALLING THE VINYL PRODUCTS AS SPECIFIED ON THE 3. COMPARTMENT STYLE: OVERHEAD BRACED AND FLOOR ANCHORED. URINAL SCREEN: FLOOR "INTERIOR FINISH SCHEDULES." FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER ANCHORED. INFORMATION, CALL THE APPROPRIATE SUPPLIER FOR THE AREA THE STORE IS LOCATED IN. 4. DOORS: MIN 24" WIDE FOR STANDARD TOILET COMPARTMENTS AND 32" CLEAR OPENING A. MATS INC. AT (781) 573-0292. COMPARTMENTS FOR ACCESSIBLE STALLS. B. INTERFACE SERVICES AT (508) 523-1859. 5. DOOR HARDWARE: CLEAR ANODIC ALUMINUM OR CAST -ZINC ALLOY. PROVIDE UNITS THAT COMPLY WITH ACCESSIBILITY REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. PROVIDE 2.I', GC TO PROVIDE AND INSTALL LUXURY VINYL TILE AS SCHEDULED PER DRAWINGS. INSTALL PER U-SHAPED DOOR PULL HARDWARE ON BOTH OUT -SWING AND IN -SWING SIDE OF THE MFR REQUIREMENTS. SEE ROOM FINISH SCHEDULE FOR SPECIFIC SIZE/FINISH MATERIAL SPEC. ACCESSIBLE COMPARTMENT DOOR. MOUNT ALL OPERATING HARDWARE NO HIGHER THAN 40" AFF. 3. RUBBER WALL BASE AS SCHEDULED, INSTALL PER MFR. REQUIREMENTS, 6. SELF -CLOSING HINGES: ADJUSTABLE TO HOLD DOOR OPEN AT ANY ANGLE UP TO 90 DEGREES. 4. GC TO CONDUCT RH MOISTURE TEST ON NEW AND EXISTING LUXURY VINYL TILE, 7. LATCHES: CONCEALED WITH DESIGNED FOR EMERGENCY ACCESS AND ADA LEVER HANDLE. SECTIONS- 09.68.13 - TILE CARPETING 8. ACCESSORIES: PROVIDE BRACKETS, PILASTER SHOES, BRACING, AND OTHER COMPONENTS 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE SUPPLIERS REQUIRED FOR A COMPLETE INSTALLATION. BELOW FOR FURNISHING AND INSTALLING THE VINYL PRODUCTS AS SPECIFIED ON THE "INTERIOR FINISH SCHEDULES." FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER g CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR REVIEW/APPROVAL. INFORMATION, CALL THE APPROPRIATE SUPPLIER FOR THE AREA THE STORE IS LOCATED IN. A. MATS INC. AT 781 573-0292, ( ) 10. GRAB BAR REINFORCEMENT: PROVIDE CONCEALED INTERNAL REINFORCEMENT FOR GRAB BARS MOUNTED ON UNITS OF SIZE AND MATERIAL ADEQUATE FOR PANEL TO WITHSTAND APPLIED DOWNWARD LOAD ON GRAB BAR OF AT LEAST 250LBF WHEN TESTED ACCORDING TO ASTM F B. INTERFACE SERVICES AT (508) 523-1859. 446, WITHOUT DEFORMATION OF PANEL 2. CARPET TILE SHALL BE INTERFACE GRAPHLAR TILE - NEEDLEPUNCH CONSTRUCTION. INSTALL SECTION 10.28.00 - TOILET ACCESSORIES IN 1/4 TURN PATTERN. II 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH GRAINGER 3. _ FOAM BACKER CARPET TILE SHALL BE INTERFACE CUSHIONBAC PLUS TILE TUFTED INDUSTRIAL SUPPLY. SUPPLY AND COMPLETE INSTALLATION SHALL BE BY THE CONTRACTOR. TEXTURED LOOP SEND ORDERS VIA EMAIL TO CVS@GGRAINGER.COM. FOR FURTHER INFORMATION, PLEASE CALL MARK CASTONGUAY OF GRAINGER AT (774) 274-2729. 4.I', INSTALL ALL CARPET MATERIALS PER MFR. REQUIREMENTS 2. PROVIDE ALL TREATED WOOD BLOCKING AND HARDWARE AS REQUIRED. SECTION 09.71.00 - WATERPROOF WALL PANELS 3. REFER TO THE DRAWINGS FOR SCHEDULE OF ITEMS. MOUNT ALL ITEMS TO MEET ADA REQUIREMENTS. 1.I GC TO PROVIDE AND INSTALL WATERPROOF WALL PANELS WHERE SHOWN ON THE DRAWINGS AND AS NEEDED FOR COMPLETE AND PROPER INSTALLATION. SECTION 10.44.00 - PORTABLE FIRE EXTINGUISHERS 2. MANUFACTURER: MARLITE: 202 HARGER STREET, DOVER, OH. 44622, AID TEL: (330) 343-6621, FAX: (330) 343-7296 1. PROVIDE FIRE EXTINGUISHERS OF TYPE SIZE AND CAPACITY FOR EACH LOCATION INDICATED. 3., WALL PANELS: 2. INSTALL IN LOCATIONS AND AT MOUNTING HEIGHTS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. A. MARLITE FRP (FIBER REINFORCED PANELS) PANELS: B. SIZE: 4' - 0" X 8' - 0". 3. PROVIDE MANUFACTURER'S STANDARD STEEL BRACKETS FOR EXTINGUISHERS. C. SHEET THICKNESS: 3/32 (2.4MM) NOMINAL. D. COLOR: P100 WHITE. 4. MULTIPURPOSE DRY-CHEMICIAL TYPE: UL-RATED 4-A: 60-B: C, 10-16 NORMAL CAPACITY IN E. FINISH TEXTURE: PEBBLE SURFACE. ENAMELED -STEEL CONTAINERS. 4.'I TRIM: MATCHING MARLITE®MOLDING TRIM AS SUPPLIED BY PANEL MANUFACTURER FOR SECTION 10.44.00 - FIRE PROTECTION SPECIALTIES OUTSIDE/INSIDE CORNERS, VERTICAL JOINTS, OPENINGS, OUTSIDE ANGLES, END CAPS, AND 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE CEILING INTERSECTIONS. MANUFACTURERS LISTED BELOW TO FURNISH AND INSTALL THE FIRE ALARM SYSTEM SPECIFIED 1N THIS SECTION. COMPLETE INSTALLATION SHALL BE BY THE NATIONAL 5. FASTENERS: MANUFACTURERS STANDARD RIVETS. ACCOUNT SUPPLIER, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE MANUFACTURER FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER 6.I ADHESIVE: NON-FLAMMABLE ADHESIVE AS RECOMMENDED BY THE MANUFACTURER FOR INFORMATION, PLEASE CALL THE APPROPRIATE MANUFACTURER FOR THE AREA THE SUBSTRATE ENCOUNTERED. STORE IS LOCATED IN. 7. SEALANT: AS RECOMMENDED BY PANEL MANUFACTURER. A. BASS SECURITY AT (888) 774-3400 AT EXT. 1950 AREAS: IL, IN, MI„ OH B. AFA PROTECTIVE SYSTEM AT (781) 848-6200 AREAS: AL, FL, GA, MA, ME, NC, NH, NY, 8. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE PA, RI, SC, VT AND PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR, SUBJECT TO THE APPROVAL C. TECHONOCALITY AT 646 723-4410 AREAS: CT, DC, DE, MD ( ) OF THE ARCHITECT. D. INTEGRATED SECURITY SOLUTIONS AT (800) 505-0868 AREA: NJ 9. INSTALLATION OF PANELS SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S E. VECTOR SECURITY AT (703) 468 6100 AT EXT. 51126 AREA: AK, CA, CO, HI, ID, IL, IN, RECOMMENDATIONS. PROMPTLY, UPON COMPLETION OF INSTALLATION, CLEAN ALL EXPOSED KY, MI, MT, NM, NV, OH, OR, PR, TN, UT, VA, WA, WV, WY SURFACES WITH METHODS AND MATERIALS RECOMMENDED BY THE MANUFACTURER OF THE F. ADVANCED PROJECT SOLUTIONS, LLC AT (608) 204-8640 AREA: AR, IA, KS, MO, MS, ND, PANELS. NE, OK, SD, WI SECTION 09.72.00 - WALL COVERINGS 2. GENERAL: NONCODED, ZONED SYSTEM WITH MANUAL AND AUTOMATIC ALARM INITIATION; AND 1. CVS/PHARMACY HAS ENTERED INTO AN AGREEMENT WITH WOLF GORDON FOR FURNISHING THE HARD -WIRED FOR SIGNAL TRANSMISSION, USING SEPARATE INDIVIDUAL CIRCUITS FOR EACH WALL COVERING AS SPECIFIED IN THIS SECTION. COMPLETE INSTALLATION SHALL BE BY THE ZONE OF ALARM INITIATION AND NOTIFICATION APPLIANCES. CONTRACTOR, FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER INFORMATION, CALL WOLF GORDON AT (800) 347-0550. 3. INSTALLER QUALIFICATIONS: AN EXPERIENCED INSTALLER WHO IS AN AUTHORIZED 2, GC TO PROVIDE AND INSTALL ALL WALL COVERINGS AS SHOWN ON DRAWINGS AND AS NEEDED REPRESENTATIVE OF THE FACP MANUFACTURER FOR BOTH INSTALLATION AND MAINTENANCE FOR COMPLETE AND PROPER INSTALLATION PER MFR. REQUIREMENTS OF UNITS REQUIRED FOR THIS PROJECT. 3. SEE FINISH SCHEDULE FOR MATERIAL/MANUFACTURER INFORMATION 4. MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN MANUFACTURING SYSTEMS SIMILAR SECTION 09.90.00 -PAINTING TO THOSE INDICATED FOR THIS PROJECT AND WITH A RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE. 1. PAINT ALL; WALL SURFACES, DOOR FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERE 5. COMPLIANCE WITH LOCAL REQUIREMENTS: COMPLY WITH APPLICABLE BUILDING CODE, LOCAL INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO ORDINANCES AND REGULATIONS, AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. WALLS RECEIVING PAINT AND RELOCATE ITEMS. 2. PROVIDE ALL LABOR AND MATERIALS AS NECESSARY FOR FINISHES AS INDICATED IN THESE 6. COMPLY WITH NFPA 72. SPECIFICATIONS. 7, FURNISH EXTRA MATERIALS DESCRIBED BELOW THAT MATCH PRODUCTS INSTALLED AND THAT 3. ACCEPTABLE PAINT MANUFACTURERS INCLUDE: SHERWIN WILLIAMS, PPG, AND BENJAMIN ARE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS MOORS DESCRIBING CONTENTS. 4. ALL FINISHES AND MATERIALS TO RECEIVE PAINT SHALL BE CLEANED THOROUGHLY AND A. SMOKE DETECTORS, FIRE DETECTORS, AND FLAME DETECTORS: QUANTITY EQUAL TO 10 PREPARED PER MANUFACTURES RECOMMENDATIONS. B. PERCENT OF AMOUNT OF EACH TYPE INSTALLED, BUT NOT LESS THAN ONE UNIT OF C. EACH TYPE. 5. INTERIOR DRYWALL D. DETECTOR BASES: QUANTITY EQUAL TO 2 PERCENT OF AMOUNT OF EACH TYPE 1 COAT LATEX PRIMER E: INSTALLED, BUT NOT LESS THAN ONE UNIT OF EACH TYPE. F. KEYS AND TOOLS: ONE EXTRA SET FOR ACCESS TO LOCKED AND TAMPERPROOFED BE BY THE CONTRACTOR. FOR PRICING QUOTATIONS, PLACING ORDERS; AND FURTHER INFORMATION, PLEASE CALL THE APPROPRIATE MANUFACTURER FOR THE AREA THE STORE IS LOCATED IN. 8. COMPONENTS. ATLAS SIGNS AT (561) 863-6659, CONTACT ANNETTE SOUTHERN 15. EQUIPMENT INSTALLATION: AREAS: AL, IN, KY, MI, MS, OH, TN, WV CHANDLER AT (214) 902-2000 EXT. 6528, CONTACT WALTER FINNINGER-OR DOUG HALLAM A. CONNECT THE FACP WITH A CIRCUIT BREAKER WITH LOCKABLE HANDLE OR COVER. AREAS: AR, KS, LA, MO, OK, TX B. MANUAL PULL STATIONS: MOUNT SEMIFLUSH IN RECESSED BACK BOXES. COAST SIGNS AT (714) 615-3141, CONTACT ERNIE RIVAS C. WATER -FLOW DETECTORS AND VALVE SUPERVISORY SWITCHES: CONNECT FOR EACH AREAS: CENTRAL CA SPRINKLER VALVE STATION REQUIRED TO BE SUPERVISED. SUPPLIED AND INSTALLED BY FLOURESCO LIGHTING & SIGNS AT (909) 647-8588, CONTACT RON HILL SPRINKLER CONTRACTOR. AREAS: AZ, SOUTHERN CA, NV D. CEILING -MOUNTED SMOKE DETECTORS: NOT LESS THAN 4 INCHES FROM A SIDE WALL TO ICON IDENTITY SOLUTIONS AT (727) 373-2033, CONTACT JON ALLEN THE NEAR EDGE. FOR EXPOSED SOLID -JOIST CONSTRUCTION, MOUNT DETECTORS ON THE BOTTOM OF JOISTS. ON SMOOTH CEILINGS, INSTALL NOT MORE THAN 30 FEET APART IN AREAS: NORTHERN CA, CO, HI, IA, ID, IL, MN, MT, ND, NE, NM, OR, SD, UT, WA, WI, WY ANY DIRECTION. IMAGE ONE AT (215) 826-0880, CONTACT PAUL SILVER E. WALL -MOUNTED SMOKE DETECTORS: AT LEAST 4 INCHES, BUT NOT MORE THAN 12 AREAS: NJ INCHES, BELOW THE CEILING. POYANT SIGNS AT (508) 995-1777 EXT. 133, CONTACT NATALIA PELLETIER F. SMOKE DETECTORS NEAR AIR REGISTERS: INSTALL NO CLOSER THAN 60 INCHES. AREAS: CT, MA, ME, NH, RI, VT G. DUCT SMOKE DETECTORS: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. SERVICE NEON AT 703 354-3000 CONTACT RICK PEPPER ( ) H. VERIFY THAT EACH UNIT IS LISTED FOR THE COMPLETE RANGE OF AIR VELOCITY, TEMPERATURE, AND HUMIDITY POSSIBLE WHEN AIR -HANDLING SYSTEM IS OPERATING. AREAS: DC, DE, MD, SC, VA I. INSTALL SAMPLING TUBES SO THEY EXTEND THE FULL WIDTH OF THE DUCT. SIGN ENGINEERING AT (787) 790-1330, CONTACT IXIA RIGS AT EXT. 235 J. AUDIBLE ALARM -INDICATING DEVICES: INSTALL NOT LESS THAN 6 INCHES BELOW THE AREAS: PR CEILING. INSTALL BELLS AND HORNS ON FLUSH -MOUNTED BACK BOXES WITH THE ULTIMATE SIGNS AT (516)481-0800, CONTACT ARLENE MELI DEVICE -OPERATING MECHANISM CONCEALED BEHIND A GRILLE. COMBINE AUDIBLE AND AREAS: NYC ONLY VISIBLE ALARMS AT THE SAME LOCATION INTO A SINGLE UNIT. K. VISIBLE ALARM -INDICATING DEVICES: INSTALL AT 80"AFF OR 6 INCHES BELOW THE _ WALTON SIGNS AT (210) 906 5986, CONTACT MARISOL JUAREZ CEILING, WHICHEVER IS LOWER. AREAS: AK, NORTHERN FL, GA L. DEVICE LOCATION -INDICATING LIGHTS: LOCATE IN PUBLIC SPACE NEAR THE DEVICE THEY MONITOR. 11. CONTRACTOR SHALL ENTER INTO A CONTRACT WITH THE SIGN COMPANY CHOSEN BY THE M. FACP: SURFACE MOUNT WITH TOPS OF CABINETS NOT MORE THAN 72 INCHES ABOVE THE OWNER FOR INSTALLATION OF PYLON SIGN; DRIVE-THRU SIGNS, AND BUILDING SIGNS. FINISHED FLOOR. N. ANNUNCIATOR: INSTALL WITH THE TOP OF THE PANEL NOT MORE THAN 72 INCHES ABOVE 12. LOCATE SIGN UNITS AND ACCESSORIES WHERE INDICATED OR REQUIRED, USING MOUNTING THE FINISHED FLOOR. METHODS COMPLYING WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 16. WIRING INSTALLATION DIVISION 11_ EQUIPMENT -NOT USED A. WIRING METHOD: INSTALL WIRING AS REQUIRED BY NFPA 70, ARTICLE 760. CONCEAL DIVISION 12 _ FURNISHINGS RACEWAY EXCEPT IN UNFINISHED SPACES AND AS INDICATED. B. WIRING WITHIN ENCLOSURES: SEPARATE POWER -LIMITED AND NON -POWER -LIMITED SECTION 12.24.00 - ROLLER WINDOW SHADES CONDUCTORS AS RECOMMENDED BY THE MANUFACTURER. INSTALL CONDUCTORS PARALLEL WITH OR AT RIGHT ANGLES TO SIDES AND BACK OF THE ENCLOSURE. BUNDLE, LACE, AND 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH ROLL -A -SHADE TRAIN CONDUCTORS TO TERMINAL POINTS WITH NO EXCESS. CONNECT CONDUCTORS THAT FOR FURNISHING THE ROLLER WINDOW SHADES SPECIFIED IN THIS SECTION, SYSTEM SHALL ARE TERMINATED, SPLICED, OR INTERRUPTED IN ANY ENCLOSURE ASSOCIATED WITH THE BE SUPPLIED BY THE GENERAL CONTRACTOR AND COMPLETE INSTALLATION SHALL BE BY THE FIRE ALARM SYSTEM TO TERMINAL BLOCKS. MARK EACH TERMINAL ACCORDING TO THE MANUFACTURER UNDER CONTRACT WITH THE GENERAL CONTRACTOR, FOR PRICING SYSTEM'S WIRING DIAGRAMS. MAKE ALL CONNECTIONS WITH APPROVED CRIMP -ON QUOTATIONS, PLACING ORDERS, AND FURTHER INFORMATION, CALL ROLL -A -SHADE AT (951) TERMINAL SPADE LUGS, PRESSURE -TYPE TERMINAL BLOCKS, OR PLUG CONNECTORS. 245-5077 EXT, 111. C. CABLE TAPS: USE NUMBERED TERMINAL STRIPS IN JUNCTION, PULL AND OUTLET BOXES, CABINETS, OR EQUIPMENT ENCLOSURES WHERE CIRCUIT CONNECTIONS ARE MADE. 2. RELATED REQUIREMENTS: SECTION 06.10.00 "ROUGH CARPENTRY" FOR WOOD BLOCKING AND D. COLOR -CODING: COLOR -CODE FIRE ALARM CONDUCTORS DIFFERENTLY FROM THE NORMAL GROUNDS FOR MOUNTING ROLLER SHADES AND ACCESSORIES, SECTION 09.29.00 "GYPSUM BUILDING POWER WIRING. USE ONE COLOR -CODE FOR ALARM CIRCUIT WIRING AND A BOARD" FOR COORDINATION WITH GYPSUM BOARD ASSEMBLIES FOR INSTALLATION OF SHADE DIFFERENT COLOR -CODE FOR SUPERVISORY CIRCUITS. COLOR -CODE AUDIBLE POCKETS, CLOSURES AND RELATED ACCESSORIES AND DIVISION 16 "ELECTRICAL" FOR ALARM -INDICATING CIRCUITS DIFFERENTLY FROM ALARM -INITIATING CIRCUITS. USE ELECTRIC SERVICE FOR MOTOR CONTROLS. DIFFERENT COLORS FOR VISIBLE ALARM -INDICATING DEVICES. PAINT FIRE ALARM SYSTEM JUNCTION BOXES AND COVERS RED. 3. INSTALLER QUALIFICATIONS: INSTALLER TRAINED AND CERTIFIED BY THE MANUFACTURER WITH A MINIMUM OF TEN YEARS OF EXPERIENCE IN INSTALLING PRODUCTS COMPARABLE TO THOSE 17. IDENTIFICATION: SPECIFIED IN THE SECTION. A. IDENTIFY SYSTEM COMPONENTS, WIRING, CABLING, AND TERMINALS ACCORDING TO DIVISION 4• ENVIRONMENTAL LIMITATIONS: DO NOT INSTALL ROLLER SHADES UNTIL CONSTRUCTION AND 16 SECTION "BASIC ELECTRICAL .MATERIALS AND METHODS." FINISH WORK IN SPACES, INCLUDING PAINTING, IS COMPLETE AND DRY AND AMBIENT B. IDENTIFY SYSTEM COMPONENTS, WIRING, CABLING, AND TERMINALS ACCORDING TO DIVISION TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT THE LEVELS INDICATED FOR 16 SECTION "ELECTRICAL IDENTIFICATION." PROJECT WHEN OCCUPIED FOR ITS INTENDED USE. C. INSTALL INSTRUCTIONS FRAME IN A LOCATION VISIBLE FROM THE FACP, D. PAINT POWER -SUPPLY CIRCUIT BREAKER RED AND LABEL "FIRE ALARM." 5. FIELD MEASUREMENTS: WHERE ROLLER SHADES ARE INDICATED TO FIT TO OTHER CONSTRUCTION, VERIFY DIMENSIONS OF OTHER CONSTRUCTION BY FIELD MEASUREMENTS BEFORE FABRICATION AND INDICATE MEASUREMENTS ON SHOP DRAWINGS. ALLOW CLEARANCES 18. GROUNDING: FOR OPERATING HARDWARE OF OPERABLE GLAZED UNITS THROUGH ENTIRE OPERATING RANGE. NOTIFY ARCHITECT OF INSTALLATION CONDITIONS THAT VARY FROM DRAWINGS. COORDINATE A. GROUND CABLE SHIELDS AND E UIPMENT ACCORDING TO SYSTEM MANUFACTURER' Q S FABRICATION SCHEDULE WITH CONSTRUCTION PROGRESS TO AVOID DELAYING THE WORK. WRITTEN INSTRUCTIONS TO ELIMINATE SHOCK HAZARD AND TO MINIMIZE, TO THE GREATEST EXTENT POSSIBLE, GROUND LOOPS, COMMON MODE RETURNS, NOISE PICKUP, CROSS TALK, 6. BASIS OF DESIGN: ROLL -A -SHADE. AND OTHER IMPAIRMENTS. A. AS-1: MOTORIZED INTERIOR SUNSCREEN ROLLER SHADES AT RETAIL SECTION. 19. FIELD QUALITY CONTROL: B. RAS-2: MANUAL INTERIOR SUNSCREEN ROLLER SHADES AT VESTIBULE. A. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE 7. ACCESSORIES B. REPRESENTATIVE TO INSPECT FIELD -ASSEMBLED COMPONENTS AND CONNECTIONS AND TO SUPERVISE PRETESTING, TESTING, AND ADJUSTMENT OF THE SYSTEM. REPORT RESULTS IN A. SUN SENSOR - ONE PER ELEVATION. SUN SENSOR TO BE PLUG-IN PROVIDED WITH NEMA WRITING. PLUG. BATTERY OPERATED NOT PERMITTED. C. PRETESTING: AFTER INSTALLATION, ALIGN, ADJUST, AND BALANCE THE SYSTEM AND B. 3 CHANNEL WALL SWITCH - SEE PLANS FOR LOCATION. WALL SWITCH TO BE PLUG-IN PERFORM COMPLETE PRETESTING. DETERMINE, THROUGH PRETESTING, THE COMPLIANCE OF PROVIDED WITH NEMA PLUG. BATTERY OPERATED NOT PERMITTED. THE SYSTEM WITH REQUIREMENTS OF DRAWINGS AND SPECIFICATIONS. CORRECT DEFICIENCIES OBSERVED IN PRETESTING. REPLACE MALFUNCTIONING OR DAMAGED ITEMS C. 5 CHANNEL WIRELESS REMOTE (OPTIONAL). WITH NEW ONES, AND RETEST UNTIL SATISFACTORY PERFORMANCE AND CONDITIONS ARE ACHIEVED. PREPARE FORMS FOR SYSTEMATIC RECORDING OF ACCEPTANCE TEST RESULTS. 8 DO NOT BEGIN INSTALLATION UNTIL SUBSTRATES HAVE BEEN PROPERTY PREPARED.IF D. REPORT OF PRETESTING: AFTER PRETESTING IS COMPLETE, PROVIDE A LETTER SUBSTRATE PREPARATION IS THE RESPONSIBILITY OF ANOTHER INSTALLER, NOTIFY E. CERTIFYING THE INSTALLATION IS COMPLETE AND FULLY OPERABLE, INCLUDING THE NAMES ARCHITECT/CONTRACTOR OF ANY UNSATISFACTORY PREPARATION BEFORE PROCEEDING. AND TITLES OF WITNESSES TO PRELIMINARY TESTS. F. FINAL TEST NOTICE: PROVIDE A MINIMUM OF 10 DAYS' NOTICE IN WRITING WHEN THE A. INSTALL ROLLER SHADES LEVEL, PLUMB, AND TRUE. ALLOW PROPER CLEARANCES FOR SYSTEM IS READY FOR FINAL ACCEPTANCE TESTING. WINDOW OPERATION HARDWARE. G. MINIMUM SYSTEM TESTS: TEST THE SYSTEM ACCORDING TO PROCEDURES OUTLINED IN B. CONTRACTOR SHALL PROVIDE POWER PANELS AND CIRCUITS OF SUFFICIENT SIZE TO NFPA 72. ACCOMMODATE ROLLER SHADE MANUFACTURER'S REQUIREMENTS. H. RETESTING: CORRECT DEFICIENCIES INDICATED BY TESTS AND COMPLETELY RETEST WORK C. CONTRACTOR HCOORDINATE O T F F SHALL LOCATION ION O POWER SUPPLY OR ROLLER SHADES WITH AFFECTED BY SUCH DEFICIENCIES. VERIFY BY THE SYSTEM TEST THAT THE TOTAL SYSTEM MANUFACTURER. MEETS SPECIFICATIONS AND COMPLIES WITH APPLICABLE STANDARDS. D. CONTRACTOR SHALL SUPPLY ONE (1) SURFACE MOUNTED DUPLEX AT UNDERSIDE OF L REPORT OF TESTS AND INSPECTIONS: PROVIDE A WRITTEN .RECORD OF INSPECTIONS, , SOFFIT FOR EACH ELEVATION WITHIN 6 OF WINDOW SIDES. TESTS, AND DETAILED TEST RESULTS IN THE FORM OF A TEST LOG. SUBMIT LOG ON THE SATISFACTORY COMPLETION OF TESTS. E. ADJUST AND BALANCE ROLLER SHADES TO OPERATE SMOOTHLY, EASILY AND FREE FROM BINDING. 20. CLEANING: REMOVE PAINT SPLATTERS AND OTHER SPOTS, DIRT, AND DEBRIS, TOUCH UP F. CLEAN ROLLER SHADE SURFACES AFTER INSTALLATION, ACCORDING TO MANUFACTURER'S SCRATCHES ANDpMARRED FINISH TO MATCH ORIGINAL FINISH. CLEAN UNIT INTERNALLY USING WRITTEN INSTRUCTIONS. METHODS AND MATERIALS RECOMMENDED BY MANUFACTURER. G. ENGAGE INSTALLER TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE AND MAINTAIN ROLLER SHADE SYSTEMS. 21. DEMONSTRATION: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN H. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT OWNER'S MAINTENANCE PERSONNEL AS SPECIFIED BELOW: 1. TOUCH-UP REPAIR AND/OR REPLACE ANY DAMAGED PRODUCTS BEFORE SUBSTANTIAL COMPLETION. A. TRAIN OWNER'S MAINTENANCE PERSONNEL ON PROCEDURES AND SCHEDULES FOR STARTING AND STOPPING, TROUBLESHOOTING, SERVICING, ADJUSTING, AND MAINTAINING EQUIPMENT AND SCHEDULES. PROVIDE A MINIMUM OF 8 HOURS' TRAINING. B. TRAINING AID: USE THE APPROVED FINAL VERSION OF THE OPERATION AND MAINTENANCE MANUAL AS A TRAINING AID. SCHEDULE TRAINING WITH OWNER, THROUGH ARCHITECT, WITH AT LEAST SEVEN DAYS' ADVANCE NOTICE. 22. ON -SITE ASSISTANCE A. OCCUPANCY ADJUSTMENTS: WHEN REQUESTED WITHIN ONE YEAR OF DATE OF SUBSTANTIAL COMPLETION, PROVIDE ON -SITE ASSISTANCE IN ADJUSTING SOUND LEVELS, CONTROLS, AND SENSITIVITIES TO SUIT ACTUAL OCCUPIED CONDITIONS. PROVIDE UP TO THREE REQUESTED VISITS TO PROJECT SITE FOR THIS PURPOSE.MA SECTION 10.70.00 - EXTERIOR SIGNS 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE MANUFACTURERS BELOW FOR FURNISHING THE PYLON SIGN, MONUMENT SIGN, DRIVE-THRU SIGNS, AND BUILDING SIGNS AS SPECIFIED IN THIS SECTION, COMPLETE INSTALLATION SHALL SECTION 12.30.00 - STEEL GONDOLAS (IF NO STORE SET-UPS 1. CVS/PHARMACY HAS ENTERED INTO A NATIONAL ACCOUNT AGREEMENT WITH THE MANUFACTURERS BELOW FOR FURNISHING THE STEEL GONDOLAS IN THIS SECTION, COMPLETE INSTALLATION SHALL BE BY THE CONTRACTOR. FOR PRICING QUOTATIONS, PLACING ORDERS, AND FURTHER INFORMATION, PLEASE CALL THE APPROPRIATE MANUFACTURER FOR THE AREA THE STORE IS LOCATED IN: A. LOZIER STORE FIXTURE INC. AT (574) 825-9561. AREAS: AL, AR, IA, IL, IN, KY, LA,MD, MI, MN, MO, MS, OH, SD, TN, WI, WV, WY B. MADIX STORE FIXTURES INC. AT (203) 975-7403. AREAS: AK, AR, AZ, CA, HI, IA, ID, LA, MN, MT, ND, NM, NV, SD, TX, WY 2. INSTALLER QUALIFICATIONS: ENGAGE AN EXPERIENCED INSTALLER WHO IS AN AUTHORIZED REPRESENTATIVE OF THE MANUFACTURER FOR INSTALLATION OF THE TYPE OF STEEL GONDOLAS WALLS REQUIRED FOR THIS PROJECT. %*Cvs pharmacy" RESET STORE NUMBER. 00944 453 STATION AVENUE SOUTH YARMOUTH, MA 02664 CAP CODE: 00072 - w ii "4 STARCK ARCHITECTS 126 Cove Street Fall River, MA 02720 1 Richmond Square, Suite 120C Providence, RI 02903 MA 508.679.5733 RI 401.709.7799 STARCKARCHITECTS.COM CONSULTANT ENGINEER: CONSULTANT: [§EA-L.- REVISIONS: DRAWING/REVIEWED BY: PPY/MJT CVS PROJECT MANAGER: SH DATE: 08/08/2022 JOB NUMBER: 163445 TI TILE: SPECIFICATIONS SHEET NUMBER: G301 COMMENTS: