HomeMy WebLinkAbout453 Station Ave CVS plan 9N NOTES 1. INSTALL NEW/RELOCATE POWER POLES. REQUIRED TO FACILITATE CEILING GRID REFERENCE ELECTRICAL DWGS. MODIFICATIONS AND/OR RELOCATION OF 2. EXISTING PERIMETER SIGNAGE TO BE LIGHT FIXTURES. PROVIDE ADDITIONAL SHEET CONSISTENT WITH CURRENT CVS METAL, FLEX DUCT, HANGERS AND STANDARDS. GC AND CVS CPM TO ACCESSORIES AS REQUIRED TO RELOCATE COORDINATE DEMO, RELOCATION, AND/OR AIR TERMINAL DEVICES. HVAC AIR TERMINAL RE -USE OF ALL EXISTING GRAPHICS, DEVICES TO BE MODIFIED SHALL CONFORM 3. RELOCATION OF EXISTING SECURITY TO SMACNA STANDARDS. UPON PROJECT CAMERAS, MOTION DETECTORS, AND COMPLETION, AIR TERMINAL DEVICES AND SECURITY EQUIPMENT BY CVS VENDOR. GC MINIMUM 5' OF ASSOCIATED BRANCH SHALL COORDINATE INSTALLATION WITH DUCTWORK SHALL BE CLEANED FREE OF VENDOR. DUST AND DEBRIS. MODIFICATION TO 4. REPLACE ANY STAINED OR DAMAGED EXISTING VENTILATION AIR FLOW SHALL NOT CEILING TILE THROUGHOUT ENTIRE STORE AS BE PERMITTED. DETERMINED DURING PRE -BID 9. GC SHALL RELOCATE SPRINKLER HEADS AS WALKTHROUGH. REQUIRED TO FACILITATE CEILING GRID 5. REPAIR OR REPLACE ANY DAMAGED OR MODIFICATIONS AND/OR RELOCATION OF INOPERABLE LIGHT FIXTURES AS REQUIRED. LIGHT FIXTURES. PROVIDE ADDITIONAL 6. RELO/INSTALL NEW AISLE MARKERS PER PIPING, HANGERS, AND ACCESSORIES AS CVS SET-UP MANAGER. REQUIRED TO FACILITATE SPRINKLER PIPING 7. CLEAN ALL EXISTING HVAC DIFFUSERS AND MODIFICATIONS. FIRE PROTECTION SPRINKLER LIGHT FIXTURE LENSES THROUGHOUT THE SYSTEM MODIFICATIONS SHALL CONFORM TO ENTIRE STORE, NFPA 13 INSTALLATION AND OPERATION 8. GENERAL CONTRACTOR SHALL COORDINATE STANDARDS. FIRE SUPPRESSION SYSTEM REVISED CEILING GRID AND LIGHTING DRAWINGS SHALL BE PREPARED BY A FIXTURE LOCATIONS WITH EXISTING CEILING LICENSED FIRE PROTECTION CONTRACTOR AS DIFFUSERS AND REGISTERS, GC SHALL REQUIRED BY THE AUTHORITIES HAVING RELOCATE DIFFUSERS AND REGISTERS AS JURISDICTION, LEGEND EXISTING PARTITION TO REMAIN.7 T , GYPSUM WALLBOARD CEILING EXISTING PARTITION TO BE DEMOLISHED L` J TO BE DEMOLISHED 4) KEY NOTE DESIGNATION _ _ ACOUSTICAL CEILING TILE AND CEILING GRID TO BE DEMOLISHED EXISTING ACOUSTICAL CEILING TILE A TO REMAIN 1 COLUMN GRID FIXTURE DESIGNATIONS E EXISTING TO REMAIN D/R DEMOLISH RE/ER RELOCATE CEILING FIXTURE SCHEDULE EXISTING/DEMO/NEW SYMBOL DESCRIPTION 1 2x4 LIGHTS STRIP LIGHTS CBEE EXIT SIGNS DO a D 09 EMERGENCY LIGHTS i `� J �� MIRRORED CEILING PANEL ® ® ® POWER POLE O 4 OO SPEAKER SB 49 ® SECURITY CAMERA BUBBLE r'1 f.1 (:1 SECURITY MOTION SENSOR �® ceiling ® ceiling ceiling FIRE ALARM STROBE LIGHT/SOUNDER STROBE 1-TV 2-TV 1 TTV 1-TV 2-TV C.C.T.V. �( �( WIFI ROUTER 0 SPRINKLER HEAD Vy® HVAC SUPPLY K1 LN HVAC RETURN zry HVAC EXHAUST/TRANSFER GRILLE ® ® R1 EXHAUST FAN UH UH GAS FIRED UNIT HEATER DEMOLITION CEILING NOTES BY SYMBOL (®) 1. CLEAN EXISTING HVAC SUPPLY/RETURN 6. DEMOLISH PORTION OF EXISTING CEILING DIFFUSERS. GRID, TILES, AND HANGERS AS SHOWN. 2. G.C. SHALL PROVIDE DRAWINGS 7. DEMOLISH EXISTING PARAWASH LIGHT PREPARED BY A LICENSED FIRE FIXTURES IN THEIR ENTIRETY. PROTECTION CONTRACTOR TO THE CITY FOR APPROVAL FOR ANY MODIFICATIONS 8. DEMOLISH/REMOVE/RELOCATE EXISTING TO THE EXISTING FIRE PROTECTION EXIT SIGN AS SHOWN. RE: 1/A2. SYSTEM. 9, REPLACE EXISTING EGGCRATE TILES. 3. G.C. SHALL COORDINATE FIRE ALARM SYSTEM MODIFICATION WITH THE CVS 10. FIX/REPLACE CEILING TILES. COORDINATE VENDOR AND RELOCATE EXISTING W/CVS PM. STROBES AS REQUIRED. 11. CLEAN EXISTING MIRRORED CEILING 4. G.C. TO COORDINATE WITH CVS VENDOR TILES. FOR RELOCATION/REMOVAL OF SECURITY EQUIPMENT: INCLUDING CAMERAS, 12. REMOVE EXISTING POWER POLEs, MOTION DETECTORS, SENSORS, AND REPLACE CEILING TILES AS REQUIRED. SECURITY BUBBLES 5. REPLACE DAMAGED/STAINED CEILING TILES THROUGHOUT RETAIL AREA (UP TO 4 CASES = 32 TILES) %*Cv pharmacy " RESET STORE NUMBER- 00944 453 STATION AVENUE SOUTH YARMOUTH, MA 02664 CAP CODE: 00072 CS PROJECT NUMBER. 163445 STARC K ARCHITECTS 126 Cove Street Fall River, MA 02720 1 Richmond Square, Suite 120C Providence, RI 02903 MA 508.679.5733 RI 401.709.7799 STARCKARCHITECTS.COM CONSULTANT ENGINEER: CONSULTANT SEAL: F,ED ARC S J I/ , 4 2 �0 .951251 c� 0 J' ✓F94 N OF MPS`'PG REVISIONS: DRAWING/REVIEWED BY: PPY/MJT CVS PROJECT MANAGER: SH DATE: 08/08/2022 JOB NUMBER: 163445 TI TLE: DEMOLITION REFLECTED CEILING PLAN SHEET NUMBER: go N N O N 00 03 OVERALL DEMOLITION CEILING PLAN 10 SCALE: 1 /8" = V-0" COMMENTS: