HomeMy WebLinkAboutBLD-22-005717 Ventilator Specs Specification Data ��",� ��� ��^ ����� � Panasonic Energy Recovery Ventilator Panasonic Description 7'ylj/2N FAN Energy Recovery Ventilator provides a tempered air supply,humidity PENT/LAT/ON FAN control,and a balanced amount of exhaust to help maintain neutral pressure throughout the home. Panasonic ERV shall not be installed in a bathroom. Only one unit is needed for a 1,750 sq.ft.2 bedroom F1/-04 VE 1 (20/�C home to meet the ASHRAE 62.2 ventilation requirement. (20/ 0 CFMJ Motor/Blower: • Totally enclosed AC condenser motor rated for continuous run. • Two highly efficient blower wheels running on single motor for JI lower power consumption and decreased noise. / • Power rating shall be 120 volts and 60 Hz. `• _• Motor equipped with thermal cut-off fuse control. 101 '�;��<Housing: • Rust proof paint,galvanized steel body. 1.‹......40441/ I • Dual 4"intake and exhaust ducts. • Built in backdraft damper on exhaust duct. / • Filters on supply and exhaust air extend the life of the ERV core. 1 II 4 -♦ A' • Expandable mounting bracket up to 16"on center. I �� Grille• " 1� • Attractive design using ABS material. ~�T. All�- � :i ,8,,2 • Attaches directly to housing with torsion springs. �� `/ Warranty: g12 m,�\ • The factory warranty shall be a minimum of 3 years limited warranty on parts. Typical Specifications: ERV shall be of the ceiling mount type with no less than : / ipto--,.... 40 CFM on the exhaust port,30 CFM on the supply port,and no more than 0.8 sone as tested in accordance with HVI 915 and 916 standards at 0.1 static pressure in inches water gauge. Power consumption shall be no greater than i 20� 23 watts. Apparent Sensible Effectiveness for heating shall be no less than ---------- // 66% at 30 CFM net air flow under 32°F (0°C) as tested in accordance with 8�'--�, CSA-C439. Total Recovery Effectiveness for cooling shall be no less than 36% at 29 CFM net air flow under 95°F(35°C). The supply port damper shall close below 20°F (-7°C) to prevent freezing of the core. The motor shall be totally enclosed, AC condenser type engineered to run continuously. Power rating Fan Curve PV-04w:f shall be 120v/60Hz. Duct diameter shall be no less than 4". Ventilation Performance: ; Air Volume Setting 40 CFM 20 CFM 10 CFM 040 Static Pressure In inches w.g. 0.1 0.1 0.1 MEM Exhaust Air Volume(CFM) 40 20 10 upply Supply Air Volume(CFM) 90 20 10 OMs Noise(sons) 0.8 <0.3 N/A Power Consumption(watts) 23 21 17 Speed(RPM) 1479 1292 1095 0 $0 Power Rating 120/60 Mill ERV Core Technology: 0,0 • Indoor and outdoor air passes through Panasonic's capillary core technology. This process tempers supply air while transferring moisture and energy. IIIIMI • Built in Frost Prevention Mode prevents the core from freezing. oOD Frost Prevention Mode is free of interaction and operates without intervention. 0 1020 so a Vic% Energy Performance: Apparent Sensible Effectiveness for Heating Total Recovery Efficiency for Cooling i 66%at 30 CFM and 32°F(0°C) at 29 CFM and 95°F(36°C) As of 9/07 For Complete Installation Instructions Visit www.panasonic•com/building cOus Model Quantity Comments Project: Location: Architect: Engineer. Contractor: Submitted by: Date: Panasonic Home&Environment I One Panasonic Way I Secaucus,NJ 07094 1866-292-7292 I www.panasonic.com/building —