Loading...
HomeMy WebLinkAboutEngineer PlanLOCUS DATA O,p/Li G tic CURRENT OWNER THOMAS & JOYCE N McCAFFERTY , LOCUS PLAN REFERENCE 32248-13-2 DEED REFERENCE CTF. 222161 ZONING DISTRICT R-40 FLOOD ZONE "X" 7-16-2014 ASSESSORS MAP PARCEL OVERLAY DISTRICT LOT AREA 91 42 NOT A ZONE II (PER B.M. BOH) 18,371t S.F. SITE & SEWAGE UPGRADE PLAN ,757 DRIVING TEE CIRCLE - IN So. YARMOUTH, MASS JUNE 30, 2023 OWNER/APPLICANT: THOM AS McCAFFERTY 57 DRIVING TEE CIRCLE So. YARMOUTH, MA 02664 508-930-3566 SHEET 1 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM LOCUS MAP NOT TO SCALE: 23-0109-1 EXISTING CESSPOOLS TO BE PUMPED, CRUSHED AND REMOVED OR ABANDONED IN ACCORDANCE WITH TITLE 5. Yarmouth Health BENCHMARK TOP OF CONCRETE BOUND ELEVATION k I 7 PROPOSED 1,500 GALLON SEPTIC TANK 1� 41.8 X i i PATIO GARAGE FIRE PIT 24' OAK TO BE S REMOVED S 110.4' C,O� PROPOSED Lh Z 'D' BOX � 41.3 r PROPOSED o. ADDITION \\ 30.0' N 45.0'/ 0 I N PROPOSED o. 15'x30' 12,0' LEACHING 12 9' FIELD S N D.T.H. #1 X 41.3 11.2' PROPOSED OBS(S) X 41.2 PROPOSED VENT L❑T 9 o \ / �X 41.7 1 1 1 � I � i 1 L❑TI 8 18,371±1 S.F. LIVING ROOM HALL BATH � i BATH BED#1 BED#2 11.1' W 06g3 \ 1 \ VA 1 � vo 1 1\ 1 1 \ \ 1 1 1 1 \ 61.8 \ G 1 / \G IG X 40.7 1 I 1 10.9' 1 C LOT 7 0 20 30 40 GRAPHIC SCALE: 1 INCH = 20 FEET 1--1 If RAISE COVERS TO WITHIN 6" OF FINISH GRADE OF FOUNDATION 42.0 FINISH GRADE FINISH GRADE ELEV. 41.0 ELEV. 41.2 ELEV. 41.4 PROPOSED / / /�� CLEANOUT(S = 36' ®S= 0.015 TOP ELEV 37.10 16.0' 0S= 0.02 4" PVC 2 MIS N X 4" PVC SCH 40 5'�5= 0.02 " e o e°o a°°°o INV.= _ 1 INVINV.=39.0 37.68 U U10"TEE(S) 14"TEE INV.= 38.0 5-7" INSTALL GAS BAFFLE 4-61/2 4'_i" LIQUID LEVEL PROPOSED CRAWL SPACE SLAB ELEV. 38.0 ° 6" BASE OF CRUSHED STONE OR MECHANICALLY COMPACTED FILL 1,500 GALLON PRECAST CONCRETE SEPTIC TANK 23-0109-1 SITE & SEWAGE UPGRADE PLAN ,7-//57 DRIVING TEE CIRCLE IN So. YARMOUTH, MASS JUNE 30, 2023 OWNER/APPLICANT: THOMAS McCAFFERTY 57 DRIVING TEE CIRCLE So. YARMOUTH, MA 02664 508-930-3566 SHEET 2 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM 3 OUTLET H-20 D93 33.14 36.75 4.3' OF =l'1.d05Oo 0 0 0 O0000 0 OnOOnOOnO (3) 4" PVC PERF. PIPES 5' O.C. S.A.S. (15.0' x 30.0') CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ENGINEER TO VERIFY REMOVAL OF UNSUITABLE SOILS PRIOR TO INSTALLATION OF NEW SEPTIC SYSTEM. 4. NO PARKING OVER SEPTIC TANK IS ALLOWED. GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL v c PROPOSED VENT TION 41.3 PEA STONE OR 0 o o 1 FILTER FABRIC p0 `� j" - 1}" DOUBLE Op WASHED STONE ALL AROUND o'a a ELEV. 36.00 no try Vi 30.3 OBSERVATION PORT(S) TO GRADE /SCREW ON CAP FILTER FABRIC ° o e° OY<°Oae °°eCaYuee rou °O° Oopepoeeeee o0 5.0_ 1 5.0' 1 T5.0, END VIEW DATUM: VERTICAL DATUM: YARMOUTH GIS± BENCH MARK USED: CONCRETE BOUND ELEVATION 42.40 SYSTEM DESIGN DESIGN FLOW 3 BEDROOMS AT1 00 GPB/D 33Q GPD REQUIRED SEPTIC TANK 330 x 2 - 660 GAL. SEPTIC TANK PROVIDED = 1500 GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE C2 MIN./INCH LONG TERM APPL. RATE 0.74 GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: USING A 15' x 30' LEACHING FIELD WITH A MINIMUM OF 6" STONE UNDERNEATH 15' x 30' = 450 S.F. 450 x 0.74 G/SF = 333 GPD 333 GPD PROV > 330 GPD REQ. = 3 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) D.T.H. #1 0 DATE: MARCH 23, 2023 GROUND ELEV. 41.3 ADJ G.WATER 30.3 NO MOTTLING A LOAMY SAND 10YR 4/3 12" NO WEEPING B LOAMY SAND INDICATES DEEP DTH #1 tOYR 6/6 TEST HOLE 132" INDICATES ADJ. GROUNDWATER 26" ELEV = 39.1 _ NO OBSERVED GROUNDWATER INDICATES 38" PERC TEST C MEDIUM SAND 2.5Y 7/6 GROUNDWATER ADJUSTMENT NO WATER 132" DEPTH TO BOTTOM OF HOLE 11.0' ELEV = 30.3 VARIANCES REOUESTED 310 CMR: 1.) TO ALLOW THE TOP OF THE LEACHING FIELD TO BE 4.3' BELOW GRADE. VENT PROVIDED. B.O.H. PHIL RENAUD SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. BOB FARRELL SOIL TYPE: 1 PERC RATE: <2 MIN. PER INCH LOADING RATE: 0.74 GAL/SF/MIN