HomeMy WebLinkAbout5031 212 Mid-Tech Dr Signed Memorandum with Exhibits Received 07.25.23TO: FROM: PETITION NO.: HEARING DATE: APPLICANTS: PROPERTY: ASSESSOR'S MAP: LOT SIZE: ZONING DISTRICT: MEMORANDUM �lll JUG 25 REC'D �J COMMUNITY DEVELOPMENT Zoning Board of Appeals John W. Kenney, Esq. 5031 July 27, 2023 JDB 212 Mid -Tech Drive, LLC 186-212 Mid -Tech Drive, West Yarmouth, MA Map 84, Parcel 12 60,024 Sq. Ft. ± B-3/APD/R2\4DOD (Registered Marijuana Dispensary Overlay District) RELIEF REQUESTED: 1. Applicant is seeking a Special Permit pursuant to Sections 104.4.1 and 104.4.2 of the Zoning Bylaw to allow a condominium form of ownership for the proposed eleven G 1) contractor bays project. 2. Applicant is seeking a Special Permit pursuant to Section 104.3.2.3 to raze and replace the existing non -conforming structure located on the premises with a conforming structure. 3. Applicant is seeking a Special Permit pursuant to Section 202.5 and Section 406.5 to allow for the use of the property as a non -hazardous General building contractor's yard in the Aquifer Protection District. 4. Applicant is seeking a Special Permit, or in the alternative, a Variance, pursuant to Section 301.4.1 of the Zoning Bylaw to waive the requirement that parking areas be located at the side and/or rear of the principal structure. 5. Applicant is seeking a Special Permit, or in the alternative, a Variance, pursuant to Section 301.4.4 of the Zoning Bylaw to waive the requirement that existing trees of at least 4" (four inch) caliper within prescribed buffers be retained in parking areas for five (5) or more cars. 6. Applicant is seeking a Special Permit, or in the alternative, a Variance, pursuant to Section 301.4.6 of the Zoning Bylaw to waive the requirement that the lot contain at least one (1) tree of 3" (three inch) caliper or larger per eight (8) cars be located within the parking area and dispersed throughout the parking area for parking lots for twenty (20) or more cars. 7. Applicant is seeking a Special Permit, or in the alternative, a Variance, pursuant to Section 301.4.9 of the Zoning Bylaw to waive the requirement that all lots in the B-3 Zoning District which shall contain a business use retain existing trees of at least 4" (four inch) caliper within prescribed buffers. BACKGROUND The subject property is located at 186-212 Mid -Tech Drive, West Yarmouth, Massachusetts. The property is shown as Lots 37, 38 and 39 on Land Court Plan 37737- D. It is shown as Parcel 12 on Town of Yarmouth Assessor's Map 84. A copy of Land Court Plan 37737-D, Sheet 1 and a copy of the portion of Assessor's Map 84 showing Parcel 12 are attached hereto as Exhibits 1 and 2 for your review. The property is currently developed with a building containing 10,680 square feet according to the Town of Yarmouth's Assessor's Records. The Cape Cod Five Cents Savings Bank was the sole occupant of the building until the expiration of its lease in 2021. The bank used the building for office use and storage. The Applicant, JDB 212 Mid -Tech Drive, LLC, Jeffrey D. Bilezikian, Manager, acquired title to the property by deed dated June 21, 2019 and registered with the Barnstable County Registry of Deeds District of the Land Court on June 24, 2019 as Document No. 1,372,857 as noted on Certificate of Title No. 219782. A copy of the Deed has been submitted to the Zoning Board of Appeals as part of the application for relief. The subject properly is located in the B-3 Zoning District. It is also located in the Aquifer Protection District. It has an on -site septic system and is served by municipal water. The property is located in an area designated "Future Phases" for the installation of municipal sewer. The property will be connected to the municipal sewer system when it becomes available. DESCRIPTION OF PROPOSED PROJECT The Applicant proposes to demolish the existing two-story structure containing 10,680 square feet and build a new building, containing 11,360 square feet. The building will have a standing seem metal roof; insulated metal panel siding; and a 4-foot high concrete wall perimeter. A condominium form of ownership is proposed. The building is proposed to be divided into eleven (11) contractor bays. Each bay will have a fenced storage area to the rear of the unit with an 8' x 12' concrete pad. The fencing is proposed to be 6' high and consist of black coated chain -link fence with a gate. ZONING BACKGROUND The property is located in the B-3 Zoning District. The minimum lot size is 40,000 square feet. Locus contains 60,024 square feet. The proposed structure complies with the setback and height requirements of the B-3 Zoning District. The proposed use as General building contractor's yard (non -hazardous) is an allowed use in the B-3 Zoning District as provided in Section 202.5 of the Bylaw, but a Special Permit for the use is required due to the location of the property in the Aquifer Protection Overlay District. The Applicant applied for, and received, a Stormwater Management Permit from the Town of Yarmouth Conservation Commission. SPECIAL PERMIT CONDITIONS AND ARGUMENT Section 103.2 of the Zoning Bylaw authorizes the Zoning Board of Appeals to grant Special Permits. ,Section 103.2.2 authorizes you to grant a Special Permit if you find that the Applicant has demonstrated that no undue nuisance, hazard or congestion will be created and that there will be no substantial harm to the established or future character of the neighborhood or town. Following is an itemization of the Special Permits requested by the Applicant and an explanation as to how the project meets the criteria for granting each requested Special Permit: 1. Condominium Form of Ownership — Section 104.4 of the Zoning Bylaw addresses "Condominium Conversion." Section 104.4.1 sets forth specific requirements when "Any legally existing conforming or nonconforming structure or use" is converted to a condominium form of ownership. Section 104.4.2 allows for a Special Permit to "be issued for an entire subdivision based upon a typical condominium unit and plot plan...." Since Section 104.4.1 and 104.4.2 are both contained within Section 104.4 Condominium Conversion, and there is no separate criteria for granting a Special Permit set forth in Section 104.4.2, these sections are to be read together and apply only to the conversion of a structure or use to a condominium form of ownership. If the Zoning Board of Appeals is of the opinion that a Special Permit is required for the proposed condominium form of ownership for this project, the Applicant's proposal meets the requirements for granting the Special Permit. The existing structure has been used as office and storage space. The new structure is proposed to be used as General building contractor yard condominium bays. The bays will serve as office and storage for the individual unit owners, hence no change in use. The "declaration of condominium document(s)" consist of Master Deed which defines the units; common areas; exclusive use areas; and allowed uses of the units. The Declaration of Trust would consist of each unit owner and would be managed by unit owners serving as "trustees". The trustees are empowered to assess association fees to be paid by each unit owner to cover the costs of maintaining and repairing common areas including utility/water lines and the on - site septic system. 2. Raze and Replace Existing Building — Section 104.3.2.3 allows for a lawfully pre-existing, non -conforming structure to be razed and replaced by Special Permit if the Board of Appeals determines that the new structure either "conforms to the current dimension requirements ... or does not increase the existing non- conforming nature of the structure ..." The proposed new structure conforms to the current dimensional requirements of the Bylaw. 3. Use of PronertK as Non -Hazardous General Building Contractor's Yard - Section 202.5 of the Bylaws allows for the use of property in the B3 Zoning District as non -hazardous General building contractor's yard. However, since the property is also located within the Aquifer Protection Overlay District (Section 406 of the Bylaw), a Special Permit is required. Section 406.5 sets forth the Special Permit requirements. The Applicant has appeared before the Site Plan Review Team twice. The Applicant cannot identify a complete list of, and quantities of potentially toxic or hazardous materials (with Materials Safety Date Sheets [MSDS]) at this time since there are no known users of the units. However, the Site Plan Review process resulted in several conditions, which the Applicant has agreed to, which will insure compliance with the Bylaw requirements for issuing the Special Permit. At Site Plan Review, the Building Inspector informed the Applicant that an Occupancy Permit for the entire building will not be issued. Instead each individual unit will be issued a Certificate of Occupancy. Any change in use, or ownership, will require a new Certificate of Occupancy. The application for occupancy shall be reviewed by the Building Department, the Yarmouth Fire Department, and the Yarmouth Board of Health (see Site Plan Review Comment Sheet Date: August 16, 2022 attached hereto as Exhibit 3). The Health Department had extensive comments on the project plan which have all been incorporated into the plans to bring them into compliance with the design and operational requirements of the Bylaw. Further, the Health Department requires any prospective occupant (tenant or owner) first consult with the Health Department for approval of their proposed use and to obtain any required licenses or permits. Outdoor storage of materials require Health Department review and approval. The conditions and protocols set forth by the Building, Health and Fire Departments are designed to insure compliance with the intent of the Bylaw and its specific criteria. The Grading, Draining, and Erosion Control Plan (Sheet C4.0) show the safeguards to protect against toxic or hazardous materials discharges or spills. All toxic and hazardous waste material spills inside the building will be contained via interior floor drains which drain to an industrial wastewater holding tank with secondary containment and alarm system. All runoff from imperious surfaces shall be recharged on -site in bio-swales covered with vegetation for surface infiltration. The proposed design has received a Stormwater Management Permit from the Yarmouth Conservation Commission. The proposed project will result in a reduced design flow and reduced nitrogen load from the existing use of the property. The on -site waste disposal and other on -site operations will not violate federal or state standards for drinking water at the downgradient property boundary. The property is located in an area designated "Future Phases" of the plan for installation of the Town of Yarmouth municipal sewer system. When available, the property will connect to the system. 4. Waiver re: Location of Parking Areas — Section 301.4.1 of the Bylaw requires parking areas to be located at the side and/or rear of a principal structure. The Applicant is proposing to put the parking area in front of the building. Placing the building to the rear of the lot and the parking area in front of the building allows for better emergency vehicle access and general vehicular circulation on -site. If the building were to be moved forward and the parking to the backside of the lot, the rear of the building would have to face Mid -Tech Drive. Further, this would create an unsafe condition. If emergency vehicles had to access the site in the case of a fire, there would be the potential for the vehicle to be trapped. Finally, the proposed parking for the new building is in a similar location to the parking area for the existing building, minimizing any harm to the established or future character of the neighborhood or town. 5. Waiver of Requirement to Retain Existing Trees — Section 301.4.4 of the Bylaw requires that for parking areas for five (5) or more cars existing trees of at least 4" (four inch) caliper be retained. The Applicant is proposing to remove trees from the buffer area along Mid -Tech Drive, some of which are at least 4" caliper. The trees are being removed to install drainage swales for pre-treatment of on -site runoff. The drainage swales require a 3:1 slope. After the swales are constructed, the area will be relandscaped with 22 trees and shrub groupings per the Landscape Plan submitted, which will provide a more enhanced buffer than currently exists. Removal of the trees was approved by the Site Plan Review Committee due to "sound landscape design reasons" to allow for proper construction of the bio- swales. 6. Waive Requirement For In -Lot Trees — Section 301.4.6 of the Bylaw requires parking lots for twenty (20) or more cars contain at least one (1) tree of 3" (three inch) caliper or larger per eight (8) cars, to be located in the parking area. The Applicant is proposing a parking area for 33 cars. Pursuant to the provisions of the Bylaw, 4.1 trees are required (33 _ 8 = 4.1). The Applicant is proposing five (5) trees, but the Site Plan Review Team determined the trees were not dispersed throughout the parking area and that a Special Permit (or Variance) was required. The Applicant has located the five in -lot trees within the parking area, but in locations so as not to interfere with emergency vehicle access or general vehicle circulation (see Proposed Landscape Planting Plan submitted with Application). The location of the trees in the parking area avoids creating a hazardous condition or on -site congestion. 7. Waive Re uirement to Maintain Existing 4" four inch Cali er Trees — Section 301.4,9 requires all lots in the B3 Zoning District retain existing trees of at least 4" caliper with prescribed buffers. As stated above in #5, the Applicant is proposing to remove some trees of at least 4" caliper in the buffer area along Mid - Tech Drive to create drainage swales. After construction of the drainage swales, the buffer will be re -vegetated as per the Landscape Plan submitted. The re - vegetated buffer will provide an enhanced buffer superior to existing conditions. In summary, the property is located toward the end of Mid -Tech Drive, a road lined with similar style buildings and industrial/commercial uses. The project has been thoughtfully designed to allow for safe emergency vehicle access and general vehicular access. If approved, the project will result in enhanced buffer protection along the frontage on Mid -Tech Drive as well as better on -site treatment of runoff from impervious surfaces bringing the location into compliance with the Aquifer Protection District zoning regulations. No undue nuisance, hazard, or congestion would be created. There would be no substantial harm to the established or future character of the neighborhood or town. VARIANCE CRITERIA AND ARGUMENT Section 102.2.2 of the Bylaw authorizes the Zoning Board of Appeals to grant a variance if you find all of the following criteria are met: 1. literal enforcement of the provisions of this Bylaw would involve a substantial hardship financial or otherwise, to the petitioner or appellant. 2. The hardship is owing to circumstances relating to the soil conditions, shape or topography of such land or structures and especially affecting such land or structures, but not affecting generally the zoning district in which it is located. 3. Desirable relief may be granted without either: substantial detriment to the public good; or nullifying or substantially derogating from the intent or purpose of this Bylaw. If the Board determines that Variances are the appropriate form of relief instead of ,Special Permits for items numbered 4, S, 6, and 7 above, the proposed project meets the criteria for granting the Variances. As described in item number 4 above, the Applicant is requesting a waiver of the requirement that the parking area be located to the side or rear of the building. Items number 5 and 6 above request relief from the requirement to retain trees of 4" caliper and 3" caliper respectively. The final waiver requested is described in number 7 above. This waiver relates to the location of tees in the parking area. A literal enforcement of the provisions of the Zoning Bylaw would involve a substantial hardship to the Applicant. If the Applicant were to be required to move the building to the front of the lot to put the parking to the rear of the building, fire and emergency vehicle access would be compromised. The backside of the building, with outdoor storage areas, would front on Mid -Tech Drive. There would be no economically feasible location for the on -site bio-swales to treat runoff from impervious surfaces as required by the Aquifer Protection District regulation. The removal of buffer trees within the landscape buffer area along Mid -Tech Drive is necessary for the creation of the bio-swales which are required by the Aquifer Protection District regulations. Given the proposed use which drives the site design, there is no other area that allows for the required 3:1 slope for the bio-swales. Without the removal of the trees, the bio-swales cannot be constructed, and the project could not go forward. The hardship for each requested variance relates to the shape and topography of the lot. The property consists of three separate lots which have been combined. The resulting lot is a long, narrow, rectangular shaped lot. Due to the narrowness of the lot, there is insufficient room to build the building at the front of the lot and put the parking in the rear. The proposed use is for nonhazardous general contractor bays. It is anticipated that many of the occupants will have trucks towing trailers. They will need room to maneuver. The front of the building would have to face the back of the lot. This would put most of the impervious surface to the rear of the lot. The only economically feasible place to install the required bio-swales is at the front of the lot. The proposed use drives the site design. As a result of the site design, the only place the required 3:1 slope for the bio-swales exists is at the front of the lot along Mid -Tech Drive. To properly install the bio-swales, trees need to be removed. Without the bio- swales, the project cannot meet the Aquifer Protection District standards and could not be constructed. The in -lot trees have been located in areas within the parking area, but in locations so they do not interfere with either emergency vehicle access or general vehicular circulation. Placing the in -lot trees within islands throughout the parking area would create problems for on -site vehicular circulation given the nature of the proposed use. The narrowness of the lot does not allow for locating the in -lot trees in that manner. Desirable relief can be granted without either substantial detriment to the public good or nullifying or substantially derogating from the intent or purpose of the Zoning Bylaw. The property is located towards the end of Mid -Tech Drive, an isolated, dead-end road. The road is lined with similar style buildings and industrial/commercial uses. The existing parking lot abuts Mid -Tech Drive. Granting the requested Variances will result in an enhanced buffer zone along Mid -Tech Drive; proper on -site treatment of water runoff from impervious surfaces as required by the Aquifer Protection District; and safer, less congested traffic circulation on -site. CONCLUSION Based on the foregoing, I submit to this Board that the Applicant meets the requirements for the Special Permits and/or Variances requested. We ask that you vote in favor of the relief requested. Respectfully submitted, Jo4 W. Kenney / % l Attorney for Jeffrey D`Bilezikian, Manager JDB 212 Mid -Tech Drive, LLC 1550 Falmouth Road, Suite 12 Centerville, MA 02632 508-771-9300 EXHIBIT 3 Formal Review SITE PLAN REVIEW COMMENT SHEET Date: August 16, 2022 Map: 84 Lot: 12 Applicant: JDB 212 Mid -Tech, LLC Location: 186- 212 Mid -Tech Drive, West Yarmouth Zone: B-3/APD Persons Present: Mark Grylls Atty. John Kenney Carl Lawson Kurt Raber De . Kevin Huck John Lavelle Lt. Matt Bearse Bruce Murphy Laurie Ruszala Project -Summary Proposed 11,360 sf contractor bay building with 11 units, paved parking lot with 33 spaces, new stormwater management system, septic system, landscaping, lighting, and associated grading and utilities. Comments Ii +13/ Building: Project is located in zoning district B-3 and the APD overlay district. 4V Disturbance area is calculated, and the applicant must file an application For a stormwater Management Permit with the Yarmouth Conservation Commission. The raise and replace of the building appears to meet the setback requirements. The proposed parking is located in from of the building relief from the ZBA will be required for parking location per Section 301.2. There are no in lot trees indicated on the plan as required per section 301.4.6, Sheet C4.0 indicates that swales will be located in the front buffer area as required per section 301.4.4. Planting schedule on page L4 indicates trees / plantings will be in the drainage swale. I have questions regarding the effectiveness of the swale over time as these plantings mature. Is there an alternative to the Swale locations? Lighting plan appears adequate; however, plan does not provide a detail of the lighting fixtures to be used. It must be noted that per section 301.4.10, all lighting shall be directed onsite only, with no undue glare affecting adjoining properties. Please be sure that all lighting to include building and site faces the ground There are no potential tenants / occupants identified at this time. All occupants will be required to obtain a Certificate of Occupancy from the Building Dept. prior to occupancy. The application for all occupancies shall be reviewed by Building, YFD, and Health. All construction to comply with all applicable sections of TOY Zoning Bylaws, 780 CMR and appendant codes. Planning: The project is located near the end of Mid -Tech Drive (a dead-end road) with similar style uses and buildings in the area. 1. With parking located mostly in front of the building and a general utilitarian building, front buffers are an important design element. The proposed project includes the elimination of at least 17 larger buffer trees along Mid -Tech Drive, mainly to install the drainage swales (please note the landscape plan shows about 5 more existing trees being removed than the civil plans which should be clarified.) The Landscape plan does show the front being relandscaped with trees and some shrub groups (trees should be native species, a minimum of 3" caliper spaced every 20'). Although the shrub groupings may be helpful in screening the parking in the front, longitudinal utilities should not be placed within the required front buffers as it necessitates the removal of larger established existing trees, contrary to Sections 301.4.4 & 301.4.9. 2. Any buffer plantings required by the Bylaw should all be located on the subject property. The Landscape Plan (included with the architectural plans) shows some proposed plantings within the road right-of-way. 3. In -lot trees need to be dispersed throughout the paved surface per Section 301A.6. Trees along the outside perimeter of the parking area are not considered in -lot trees, 4. Recommend fencing be black coated vinyl rather than galvanized chain link. 5. Project has more than one acre of land disturbance and a Stormwater Management Permit is required through the Conservation Commission. Conservation: Design Review: Refer to the attached August 2, 2022 Design Review Comment Sheet Engineering: • Engineering defers detailed stormwater review for the Stormwater Management Permit as noted previously. • Suggest relocating bioswales away from landscaping buffers. • Specify which pavement detail will be used for pavement areas. • Clean, inspect and repair as necessary existing drainage to be repurposed towards the rear of the parking lot. It appears it may have been installed in 2016. Please confirm. • File road opening permit at DPW for curb cut modifications. Provide loam & seed for driveway to be abandoned. Fire: MGL 148 Section 26G: Automatic sprinkler s} steins required for buildings and structw•es yoTotaling more than 7,500 gross square feet. Compliance with the following: 527 CMR 1 Chapter 16 "Safeguarding Construction, Alteration, and Demolition Operations." 780 CMR Chapter 33, NFPA 24. Per 527 CMR J� k 1 16.1.2 u A fire protection plan shall be established and submitted" This plan shall include the following: 16.3.1 Fire safety program, 16.3.2 Owners designated fire prevention program manager, 16.3.4.1 A suitable location at the site shall be designated as a command post and provided with plans, emergency information, keys, communications and equipment as needed. Number of hydrants on site should be based on fire flow calculations 527 CMR 1.18.5.and annex E table E.3. Evaluation of Emergency responder radio coverage based on 780 CMR 915.1 and 527CMR 1.Fire Protection systems to be maintained by condo association. Health: All prospective tenants mast consult with the Health Dept. for approval of their proposed use f and to obtain any required licenses or permits before renting and occupying units. Any use or storage of toxic or hazardous materials requires prior Health Dept. approval. Toxic or hazardous materials storage in excess of 10 gallons requires a Board of Health license. Toxic or hazardous materials storage in excess of 20 gallons requires a Board of Health license and zoning relief from the Zoning Board of Appeals. Such relief is not guaranteed. All toxic and hazardous materials storage requires 150% volume secondary containment in addition to other requirements. All outdoor storage of materials including, but not limited to those used in landscaping, require Health Dept. review and approval. Vehicle washing operations are not allowed onsite either inside or outside of any building Regarding engineered plan Sheet Title: Grading and Drainage Plan; Sheet No. C4.0, dated December 10, 2021, under Operation and Maintenance Plan note 8 A, the note should be revised to indicate vehicle washing is not allowed onsite either inside or outside of any building. Regarding engineered plan Sheet Title: Septic Profile and Details Plan; Sheet No. C5.1, dated December 10, 2021: (1) The notes next to the indicated holding tank control panel should be revised to include mention of the alarm and indicator lights for the leak detection system. (2) Under Industrial Wastewater Holding Tank Design Notes, the sizing calculation needs to be revised to include the unit of time for the calculation and compare the result of the calculation to the size of the holding tank. (3) Under Tank Note 1 310 CMR 18 should be revised to 314 CMR 18 Industrial Wastewater Holding Tank and Container Construction, Operation and Record Keeping Requirements. (4) The primary holding tank and secondary containment tank must be waterproofed and noted as such on Sheet C5.1 as required by 314 CMR 18. (5) All refences to the 2500-gallon secondary containment tank must indicate H-20 construction. (6) Inner and outer holding tank covers must be in alignment with each other as indicated on plan. (7) Inner Folding tank cover must have cover indicated over inlet. (8) The 75% level high water indicator float must have the vertical distance measurement from the bottom of the tank indicated. (9) Indicate the height from the bottom of the tank of the leak detection float. (10) Sign reading "NON-HAZRDOUS INDUSTRIAL WASTE WATER" must be present on building in location adjacent to holding tank and indicated on plan. (11) How will the holding tank alarm be monitored since it is only in one unit? Is the floor pitch to the floor drains indicated on the foundation plan? The plans make two references to a 1000-gallon holding tank and one reference to a 1500- gallon holding tank as listed below. Sheet Title: Utilities Plan, Sheet No. C5.0, dated December 10, 2021 indicates "1000 gallon dual containment industrial wastewater holding tank." Sheet Title: Septic Profile and Details Plan; Sheet No. C5.1, dated December 10, 2021 under Industrial Wastewater Holding Tank Design Notes states "(1) 1000 gallon precast tank inside of 2500 gallon precast concrete tank." Sheet Title: Septic Profile and Details Plan; Sheet No. C5.1, dated December 10, 2021 the note next to indicated tank states "Dual Containment Tank Shall Consist of H-20 1500 Gallon Monolithic Precast Concrete Primary Holding Tank..." Please indicate in all three places the correct size of the holding tank. 'The design engineer must (1) complete the DEP holding tank compliance certification form and provide a copy to the Health Dept. and (2) submit a holding tank certification letter to the Health Dept. Water: lease show the exiting 12-inch water main on the utility plan as it is close to your work. In addition, please note that the re service for 211 Mid Tech is back tapped on the 12-inch main, therefore is closer to the proposed drainage basin than would be expected. Water service installation should be installed by an Approved Contractor in accordance with the Yarmouth Water Materials and Installation Standards. Read & Received by Applicant(s) SDBD7v2SION PLAN Ol LAND IN YAitMCU7Cti Low & Weller Inc., Surveyors August 29, 1984 EXHIBIT 1 R0,60rl h! Loring a Joshua G. Thacker lbdivision of Lot 2 town on Plai7 3:7737A Sh. 2 .led with Cert. o Title No 22 °gistry District of Barnstable�C County fe certificates of title 'Own hereon may be Issued for land .own the Court. �ois.2•o. •>hru•�2 ................. 7 sHeE 7 / o a _ a Sea/e 100 (eaJ�o an ukh ii 56,gn33'5��V� o + i Abutters are shown Ba on original decree plan Copy of parr of plan Nlodln LAND REGISTRATION OFFICE ✓Aw r, 1,9se Scala or this plan /oo feat to an Inch Louts A. mooro, EngineortorCu�rrt, EXHIBIT 2 O 1 _ ' I I I � I wl �I �i i I � u I u .n } 586 I y 212 sAtio �srcY1� ; � U 1 I cq sa m� I I o m I U y a LL d Ig ry p o a a w � I � 1 ¢ � I I ^ I i zo 1 5w i I �JLL y.Q J w � �3 J————————————————————— L—EBOfd --- ----------Q— — 1--------------- z'A I o 0 I D F K ea �e v kc E